Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.Fluid.HeatExchangers.DXCoils.BaseClasses.Examples.CoolingCapacityAirCooled.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: translateModel(Buildings.Fluid.HeatExchangers.DXCoils.BaseClasses.Examples.CoolingCapacityAirCooled,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.Fluid.HeatExchangers.DXCoils.BaseClasses.Examples.CoolingCapacityAirCooled") translateModel(Buildings.Fluid.HeatExchangers.DXCoils.BaseClasses.Examples.CoolingCapacityAirCooled,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.Fluid.HeatExchangers.DXCoils.BaseClasses.Examples.CoolingCapacityAirCooled") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.572/1.572, allocations: 285.5 MB / 292.8 MB, free: 10.41 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001386/0.001386, allocations: 177.3 kB / 361.1 MB, free: 7.07 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.733/1.733, allocations: 205.1 MB / 0.6195 GB, free: 10.3 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009426/0.0009426, allocations: 85.81 kB / 0.7325 GB, free: 44.23 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.047e-05/1.049e-05, allocations: 4 kB / 0.8511 GB, free: 2.949 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7606/0.7606, allocations: 115.3 MB / 0.9637 GB, free: 78.28 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.2164/0.9771, allocations: 149.8 MB / 1.11 GB, free: 6.117 MB / 0.7136 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003693/0.9775, allocations: 97.98 kB / 1.11 GB, free: 6.023 MB / 0.7136 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Fluid/HeatExchangers/DXCoils/BaseClasses/PartialCoolingCapacity.mo:37:3-41:39:writable] Error: Array equation has unknown size in cooCap.sta[1].perCur.capFunFF=sta.perCur.capFunFF. Error: Internal error - InstUtil.moveBindings: Mismatched number of equations and variables. Error: Error occurred while flattening model Buildings.Fluid.HeatExchangers.DXCoils.BaseClasses.Examples.CoolingCapacityAirCooled