Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|soi.port_a.T|soi.port_b.T|TSoiAna.y|groTem.y|deltaT.y",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week") translateModel(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|soi.port_a.T|soi.port_b.T|TSoiAna.y|groTem.y|deltaT.y",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.216/1.216, allocations: 249.4 MB / 256.7 MB, free: 7.645 MB / 206.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001/0.001, allocations: 177.3 kB / 316 MB, free: 7.938 MB / 254.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.07/1.07, allocations: 205.1 MB / 0.5667 GB, free: 3.41 MB / 414.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008457/0.0008458, allocations: 89.41 kB / 0.671 GB, free: 8.562 MB / 0.5137 GB Notification: Performance of FrontEnd - loaded program: time 6.312e-06/6.322e-06, allocations: 0 / 0.7807 GB, free: 106.8 MB / 0.545 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.142/0.142, allocations: 106.3 MB / 0.8846 GB, free: 380 kB / 0.545 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.4589/0.6009, allocations: 164.2 MB / 1.045 GB, free: 13.18 MB / 0.67 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002241/0.6012, allocations: 104.2 kB / 1.045 GB, free: 13.12 MB / 0.67 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/GroundTemperatureResponse.mo:8:3-10:87:writable] Error: Array equation has unknown size in groTemRes.borFieDat.conDat.cooBor=borFieDat.conDat.cooBor. Error: Internal error - InstUtil.moveBindings: Mismatched number of equations and variables. Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week