Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildingSystems_BuildingSystems.Fluid.HeatPumps.Validation.Carnot_y_etaPL.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo) Running command: translateModel(BuildingSystems.Fluid.HeatPumps.Validation.Carnot_y_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Fluid.HeatPumps.Validation.Carnot_y_etaPL") translateModel(BuildingSystems.Fluid.HeatPumps.Validation.Carnot_y_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Fluid.HeatPumps.Validation.Carnot_y_etaPL") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 0.7589/0.7589, allocations: 141.8 MB / 149.1 MB, free: 13.16 MB / 138.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001408/0.001408, allocations: 187.2 kB / 181.9 MB, free: 9.832 MB / 154.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.408/1.408, allocations: 221.4 MB / 436 MB, free: 2.348 MB / 330.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009898/0.0009898, allocations: 95.91 kB / 0.507 GB, free: 17.68 MB / 378.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.001873/0.001873, allocations: 274 kB / 0.5884 GB, free: 3.867 MB / 442.9 MB Notification: Performance of FrontEnd - loaded program: time 8.967e-06/8.987e-06, allocations: 2.156 kB / 0.6759 GB, free: 136.7 MB / 0.5107 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1858/0.1859, allocations: 82.78 MB / 0.7567 GB, free: 83.36 MB / 0.5107 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.7517/0.9376, allocations: 389.2 MB / 1.137 GB, free: 2.578 MB / 0.6982 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003022/0.938, allocations: 85.14 kB / 1.137 GB, free: 2.535 MB / 0.6982 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/HeatPumps/Examples/Carnot_y.mo:20:3-34:67:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope BuildingSystems.Fluid.HeatPumps.Carnot_y$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model BuildingSystems.Fluid.HeatPumps.Validation.Carnot_y_etaPL