startTime=0 stopTime=800 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.32 Regular simulation: ./AixLib_latest_AixLib.Systems.HydraulicModules.Example.Injection2WayValve -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0526491s reading init.xml | | | | | | 0.00719187s reading info.xml | | | | | | 0.000289272s pre-initialization | | | | | | 0.000817654s [ 0.4%] initialization | | | | | | 2.2442e-05s [ 0.0%] steps | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000463384s [ 0.3%] event-handling | | | | | | 0.0394706s [ 21.6%] overhead | | | | | | 0.141913s [ 77.6%] simulation | | | | | | 0.182976s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 303 steps taken | | | | | | 443 calls of functionODE | | | | | | 65 evaluations of jacobian | | | | | | 10 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00573789s time of jacobian evaluation stdout | info | The simulation finished successfully.