OMSimulator --tempDir=temp_PowerSysPro_PowerSysPro_Examples_StructuredNetwork_DoubleNetworkWithTwoOppositeBreakers_fmu --startTime=0 --stopTime=1 --timeout=50 --tolerance=1e-06 PowerSysPro_PowerSysPro_Examples_StructuredNetwork_DoubleNetworkWithTwoOppositeBreakers.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_PowerSysPro_PowerSysPro_Examples_StructuredNetwork_DoubleNetworkWithTwoOppositeBreakers_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/PowerSysPro_PowerSysPro.Examples.StructuredNetwork.DoubleNetworkWithTwoOppositeBreakers/temp_PowerSysPro_PowerSysPro_Examples_StructuredNetwork_DoubleNetworkWithTwoOppositeBreakers_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/PowerSysPro_PowerSysPro.Examples.StructuredNetwork.DoubleNetworkWithTwoOppositeBreakers" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/PowerSysPro_PowerSysPro.Examples.StructuredNetwork.DoubleNetworkWithTwoOppositeBreakers/temp_PowerSysPro_PowerSysPro_Examples_StructuredNetwork_DoubleNetworkWithTwoOppositeBreakers_fmu/model-ltgdmn6e" stdout | info | The initialization finished successfully without homotopy method. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | src1.tra2.SA <= 250000.0 assert | warning | >>> Apparent power flowing the transformer is exceeding the nominal power for DoubleNetworkWithTwoOppositeBreakers.src1.tra2 assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not feeder2.load1.U < feeder2.load1.minU assert | warning | >>> Voltage is below the minimum acceptable value for DoubleNetworkWithTwoOppositeBreakers.feeder2.load1 assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not feeder2.load4.U < feeder2.load4.minU assert | warning | >>> Voltage is below the minimum acceptable value for DoubleNetworkWithTwoOppositeBreakers.feeder2.load4 assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not feeder1.load1.U < feeder1.load1.minU assert | warning | >>> Voltage is below the minimum acceptable value for DoubleNetworkWithTwoOppositeBreakers.feeder1.load1 assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not feeder1.load4.U < feeder1.load4.minU assert | warning | >>> Voltage is below the minimum acceptable value for DoubleNetworkWithTwoOppositeBreakers.feeder1.load4 info: model doesn't contain any continuous state info: Result file: model_res.mat (bufferSize=10) assert | warning | The following assertion has been violated at time 0.260101 | | | | src2.tra2.SA <= 250000.0 assert | warning | >>> Apparent power flowing the transformer is exceeding the nominal power for DoubleNetworkWithTwoOppositeBreakers.src2.tra2