OMSimulator --tempDir=temp_PowerSysPro_PowerSysPro_Examples_OneSourceThreeLinesOneSource_fmu --startTime=0 --stopTime=1 --timeout=50 --tolerance=1e-06 PowerSysPro_PowerSysPro_Examples_OneSourceThreeLinesOneSource.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_PowerSysPro_PowerSysPro_Examples_OneSourceThreeLinesOneSource_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/PowerSysPro_PowerSysPro.Examples.OneSourceThreeLinesOneSource/temp_PowerSysPro_PowerSysPro_Examples_OneSourceThreeLinesOneSource_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/PowerSysPro_PowerSysPro.Examples.OneSourceThreeLinesOneSource" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/PowerSysPro_PowerSysPro.Examples.OneSourceThreeLinesOneSource/temp_PowerSysPro_PowerSysPro_Examples_OneSourceThreeLinesOneSource_fmu/model-fnn55xrv" stdout | info | The initialization finished successfully without homotopy method. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | line3.IA <= 50.0 assert | warning | >>> Current flowing the line is exceeding the maximum admissible current for OneSourceThreeLinesOneSource.line3 info: model doesn't contain any continuous state info: Result file: model_res.mat (bufferSize=10)