Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater,fileNamePrefix="Buildings_latest_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_ElectricHeater",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater,fileNamePrefix="Buildings_latest_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_ElectricHeater",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 1.766/1.766, allocations: 390.4 MB / 397.7 MB, free: 10.7 MB / 330.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001/0.001, allocations: 185.5 kB / 490.8 MB, free: 11.23 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.111/1.111, allocations: 221.4 MB / 0.7863 GB, free: 13.61 MB / 0.5886 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008926/0.0008926, allocations: 105.6 kB / 0.9264 GB, free: 4.578 MB / 0.6667 GB Notification: Performance of FrontEnd - loaded program: time 0.249/0.2499, allocations: 149.1 MB / 1.072 GB, free: 15.5 MB / 0.823 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5323/0.7823, allocations: 143 MB / 1.212 GB, free: 155.9 MB / 0.8855 GB Notification: Performance of FrontEnd - scodeFlatten: time 2.654/3.436, allocations: 1.976 GB / 3.187 GB, free: 98.29 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0001989/3.436, allocations: 103.9 kB / 3.187 GB, free: 98.18 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/BaseClasses/Euler/getPeak.mo:9:3-10:49:writable] Warning: Component peak in env: Buildings.Fluid.Movers.BaseClasses.Euler.getPeak has the same name as its type Buildings.Fluid.Movers.BaseClasses.Euler.peak. This is forbidden by Modelica specification and may lead to lookup errors. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/Data/Generic.mo:90:3-92:29:writable] Error: Class Buildings.Fluid.Movers.BaseClasses.Euler.getPeak not found in scope Buildings.Fluid.Movers.Data.Generic (looking for a function or record). Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater Error: Internal error SimCode: The model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater could not be translated to FMU