Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Calibration.ScrollWaterToWater,fileNamePrefix="Buildings_5_0_1_Buildings_Fluid_HeatPumps_Calibration_ScrollWaterToWater",fmuType="me",version="2.0",platforms={"dynamic"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadModel(Buildings): time 4.025/4.025, allocations: 404 MB / 410.9 MB, free: 4.953 MB / 314.7 MB Notification: Performance of FrontEnd - loaded program: time 0.2888/4.314, allocations: 95 MB / 0.4941 GB, free: 7.344 MB / 410.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5401/4.854, allocations: 92.68 MB / 0.5846 GB, free: 3.387 MB / 474.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 1.06/5.914, allocations: 400.1 MB / 0.9753 GB, free: 32.75 MB / 0.6823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003669/5.914, allocations: 91.39 kB / 0.9754 GB, free: 32.7 MB / 0.6823 GB [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2312:7-2313:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$calDat.getTableValue. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$calDat.getTableTimeTmin. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$calDat.getTableTimeTmax. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/Media/Refrigerants/R410A.mo:582:3-582:35:writable] Error: Variable A not found in scope Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/Media/Refrigerants/R410A.mo:326:3-326:84:writable] Error: Class Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv not found in scope Buildings.Fluid.HeatPumps.Compressors.ScrollCompressor$heaPum$com.ref.isentropicExponentVap_Tv (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Calibration.ScrollWaterToWater Error: Internal error SimCode: The model Buildings.Fluid.HeatPumps.Calibration.ScrollWaterToWater could not be translated to FMU