ThermoSysPro test using OpenModelica

Total Invalid Frontend Backend SimCode Templates Compilation Simulation Verification
245 241 245 241 237 237 237 192 0

Test started: 2026-11-18 16:57:35
Total time taken: 0:34:24
System info: ryzen-9950x: AMD Ryzen 9 9950X3D 16-Core Processor, 124 GB RAM, Ubuntu 26.04.1 LTS

OpenModelica Version: v1.28.0-dev.1993+gde3334196d.rust
OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
ed6cc902026-11-18 13:25:01 +0100Martin SjölundGive OMPlot the tube and tolerances of the check (#432)

Tested Library: ThermoSysPro 4.2

{
 "path": "ThermoSysPro",
 "sha": "953deb07b1d154091e0af7f6b0fa817a319babd3",
 "support": "noSupport",
 "version": "4.2.0-master",
 "zipfile": "https://github.com/EDF-Lab/ThermoSysPro/archive/953deb07b1d154091e0af7f6b0fa817a319babd3.zip"
}

BuildModel time limit: 660s
Simulation time limit: 240s
Simulation time limit for ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation: 360s
Simulation time limit for ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7: 570s
Simulation time limit for ThermoSysPro.Fluid.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation: 360s
Simulation time limit for ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicWaterHeating: 540s
Default tolerance: 1e-06
Default number of intervals: 2500
Optimization level: Tool default

Flags:
setCommandLineOptions("--simCodeTarget=wasm-jit")
setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
setCommandLineOptions("--warnNonStandardModelica");
Config:
{
 "library": "ThermoSysPro",
 "libraryVersion": "master",
 "libraryVersionNameForTests": "",
 "ulimitExeModels": {
  "ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation": 360,
  "ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7": 570,
  "ThermoSysPro.Fluid.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation": 360,
  "ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicWaterHeating": 540
 }
}

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

A model marked ✘ is invalid: omc translates it only because --warnNonStandardModelica turns the errors of non-standard Modelica into warnings. Hover over the cross to see which --allowNonStandardModelica options it needs.

ModelVerifiedSimulateTotal buildModelParsingFrontendBackendSimCodeTemplatesCompileTotal Execution
✘ ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip (sim) 240.0311.500.101.345.100.880.323.86252.30
✘ ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation (sim) 210.1511.830.071.405.130.950.373.97222.73
✘ ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC (sim) 0.248.260.080.764.330.710.222.249.18
✘ ThermoSysPro.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant 0.004.610.091.122.930.450.110.005.29
✘ ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_1 (sim) 0.020.530.080.280.080.010.010.161.17
✘ ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_2 (sim) 0.010.520.090.280.070.010.010.151.17
✘ ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_3 (sim) 0.070.960.080.500.240.010.010.211.71
✘ ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_4 (sim) 0.040.540.080.300.070.010.010.161.31
✘ ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestStaticCentrifugalPump (sim) 0.050.500.080.250.080.010.010.151.22
✘ ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding 0.000.670.080.580.090.000.000.001.27
✘ ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.NegativeFlow 0.000.670.080.590.090.000.000.001.32
✘ ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow 0.000.680.070.590.090.000.000.001.22
✘ ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicCondenser (sim) 0.241.070.080.300.380.050.020.311.97
✘ ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicOnePhaseFlowShell (sim) 0.040.810.080.240.190.040.020.321.49
✘ ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicTwoPhaseFlowPipe (sim) 2.441.290.080.320.440.080.030.424.36
✘ ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestStaticCondenser (sim) 0.000.710.080.320.150.020.010.211.39
✘ ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestBend (sim) 0.010.810.130.320.140.030.030.291.54
✘ ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestCheckValve (sim) 0.011.100.090.300.130.010.060.611.81
✘ ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestControlValve (sim) 0.010.940.090.590.130.010.010.201.62
✘ ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestDiaphragm (sim) 0.010.940.120.570.160.010.010.191.64
✘ ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestDynamicCheckValve (sim) 0.711.120.260.760.130.010.010.212.76
✘ ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestDynamicReliefValve (sim) 6.051.860.420.780.260.020.090.719.02
✘ ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestLumpedStraightPipe (sim) 0.081.010.090.500.170.010.010.321.74
✘ ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestPipePressureLoss (sim) 0.010.620.080.290.140.010.010.171.33
✘ ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestSwitchValve (sim) 0.021.330.090.690.270.010.090.262.04
✘ ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestThreeWayValve (sim) 0.041.080.080.310.150.010.010.601.89
✘ ThermoSysPro.Examples.Book.SimpleExamples.SolarCollector.TestFresnelField (sim) 2.125.730.090.692.240.330.152.318.50
✘ ThermoSysPro.Examples.Book.SimpleExamples.SteamTurbine.TestStodolaTurbine (sim) 0.010.770.080.350.160.010.010.241.51
✘ ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestDynamicDrum (sim) 12.863.790.411.230.710.100.091.6517.70
✘ ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestMixer3 (sim) 0.031.370.350.770.140.030.010.412.38
✘ ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestPressurizer (sim) 0.132.110.391.240.280.010.050.533.29
✘ ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestSplitter3 (sim) 0.011.170.340.790.120.010.010.242.16
✘ ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestStaticDrum3 (sim) 0.012.870.281.370.450.120.090.833.74
✘ ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestSteamDryer (sim) 0.020.810.140.340.120.010.010.331.59
✘ ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestTank (sim) 0.132.270.361.330.280.060.010.583.41
✘ ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestVolumeATh (sim) 0.101.990.371.190.210.010.010.573.13
✘ ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 0.6118.030.452.405.531.010.738.3619.82
✘ ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 0.0416.800.261.934.940.730.708.5017.82
✘ ThermoSysPro.Examples.SimpleExamples.TestAirHumidity (sim) 0.001.370.401.230.020.000.000.122.46
✘ ThermoSysPro.Examples.SimpleExamples.TestBend (sim) 0.011.410.470.830.150.010.020.402.62
✘ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 0.071.350.320.760.100.010.020.472.34
✘ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim) 0.021.290.390.810.090.010.010.372.32
✘ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump2 (sim) 0.062.040.291.290.240.010.010.492.97
✘ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim) 0.241.790.361.080.190.020.010.492.98
✘ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim) 0.182.680.551.670.220.020.040.744.14
✘ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump5 (sim) 0.061.790.551.080.150.010.060.483.13
✘ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump6 (sim) 0.082.470.411.590.250.010.040.573.65
✘ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 74.451.680.410.900.180.020.020.5777.20
✘ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim) 0.010.830.390.600.070.010.010.151.84
✘ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim) 0.011.120.080.480.120.010.060.451.80
✘ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10 (sim) 0.020.870.320.540.150.010.010.153.95
✘ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim) 0.031.540.380.730.230.010.010.562.64
✘ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim) 0.020.700.120.440.070.010.030.151.41
✘ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump13 (sim) 0.020.490.320.250.070.010.010.161.51
✘ ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution (sim) 0.000.310.080.230.020.020.000.051.01
✘ ThermoSysPro.Examples.SimpleExamples.TestCheckValve (sim) 0.161.300.080.540.280.020.010.442.17
✘ ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim) 0.011.290.080.520.170.010.010.581.95
✘ ThermoSysPro.Examples.SimpleExamples.TestControlValve (sim) 0.010.990.090.700.120.010.010.151.69
✘ ThermoSysPro.Examples.SimpleExamples.TestDiaphragm (sim) 0.010.700.280.410.130.010.010.151.58
✘ ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 2.370.520.080.270.080.010.010.163.53
✘ ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 0.220.990.110.290.080.010.030.591.85
✘ ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 0.251.180.080.730.200.020.010.222.04
✘ ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve (sim) 0.710.880.420.590.130.010.010.142.65
✘ ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 0.393.620.080.670.650.220.101.984.67
✘ ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 0.403.490.200.570.740.130.211.854.67
✘ ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum2 (sim) 5.993.090.091.150.660.130.081.079.77
✘ ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum3 (sim) 0.383.440.361.710.780.100.040.804.74
✘ ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum_CC (sim) 14.643.110.101.050.640.100.131.1818.42
✘ ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim) 0.101.560.310.350.220.040.020.932.59
✘ ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 0.182.300.291.020.250.010.150.873.36
✘ ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim) 2.992.750.311.010.780.160.060.746.70
✘ ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 2.134.080.080.611.730.290.111.336.87
✘ ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding 0.000.730.080.620.110.000.000.001.29
✘ ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger (sim) 0.080.830.100.240.300.020.060.211.66
✘ ThermoSysPro.Examples.SimpleExamples.TestFan 0.000.780.070.540.180.060.000.001.41
✘ ThermoSysPro.Examples.SimpleExamples.TestFan_Pin 0.000.550.090.350.140.050.000.001.16
✘ ThermoSysPro.Examples.SimpleExamples.TestFan_Qin 0.000.580.100.350.180.050.000.001.19
✘ ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions (sim) 0.010.420.080.350.020.010.000.041.08
✘ ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes (sim) 0.080.510.080.350.040.010.000.101.22
✘ ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1 0.000.500.080.340.090.010.050.001.09
✘ ThermoSysPro.Examples.SimpleExamples.TestFresnelField (sim) 2.784.050.080.442.110.310.101.097.49
✘ ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve (sim) 0.151.010.080.490.270.020.010.221.80
✘ ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve (sim) 0.020.970.080.520.240.010.010.191.67
✘ ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss (sim) 0.010.550.090.270.110.010.010.151.21
✘ ThermoSysPro.Examples.SimpleExamples.TestJunctions1 (sim) 0.060.670.080.310.160.020.020.171.36
✘ ThermoSysPro.Examples.SimpleExamples.TestJunctions2 (sim) 0.040.740.080.350.170.020.010.191.45
✘ ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim) 0.221.070.110.570.260.020.010.211.99
✘ ThermoSysPro.Examples.SimpleExamples.TestJunctions4 (sim) 0.020.610.120.280.180.010.010.141.34
✘ ThermoSysPro.Examples.SimpleExamples.TestJunctions5 (sim) 0.181.090.080.530.290.020.010.231.89
✘ ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker (sim) 0.010.460.080.240.060.010.010.141.12
✘ ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe (sim) 0.390.900.110.510.170.010.010.201.97
✘ ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier (sim) 0.010.490.080.270.070.010.010.131.15
✘ ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim) 0.060.710.080.300.200.020.010.191.44
✘ ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim) 0.070.670.120.310.140.020.010.191.38
✘ ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 0.150.730.120.290.190.020.010.221.60
✘ ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss (sim) 0.010.560.080.270.120.010.010.151.20
✘ ThermoSysPro.Examples.SimpleExamples.TestPressurizer_CC (sim) 0.121.030.080.520.280.020.010.201.83
✘ ThermoSysPro.Examples.SimpleExamples.TestRefP (sim) 0.010.860.120.490.170.010.010.181.59
✘ ThermoSysPro.Examples.SimpleExamples.TestSensors (sim) 0.020.950.080.520.220.010.010.191.59
✘ ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases (sim) 0.020.640.080.420.070.010.010.141.38
✘ ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser (sim) 0.020.480.080.230.110.010.010.141.19
✘ ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss (sim) 0.010.580.080.280.120.010.010.171.20
✘ ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 0.050.540.130.280.080.010.010.161.31
✘ ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump1 (sim) 0.010.600.090.300.130.010.010.151.32
✘ ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump2 (sim) 0.060.580.080.300.080.010.010.171.38
✘ ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim) 0.000.270.080.190.010.020.000.050.92
✘ ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 0.040.720.100.310.160.020.010.201.47
✘ ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 0.000.620.090.320.130.010.010.151.32
✘ ThermoSysPro.Examples.SimpleExamples.TestStaticDrum2 (sim) 0.030.580.120.300.120.010.010.141.32
✘ ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases (sim) 0.020.680.080.470.060.010.010.131.38
✘ ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger (sim) 0.020.580.080.280.120.010.010.161.26
✘ ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff (sim) 0.020.520.090.250.100.010.010.151.26
✘ ThermoSysPro.Examples.SimpleExamples.TestSteamDryer1 (sim) 0.020.600.090.290.130.010.010.173.36
✘ ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim) 0.020.650.080.360.120.010.010.151.30
✘ ThermoSysPro.Examples.SimpleExamples.TestSteamEngine (sim) 0.010.640.090.340.100.010.010.181.33
✘ ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter (sim) 0.020.630.080.310.130.010.010.171.35
✘ ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 0.130.780.090.310.170.020.010.271.69
✘ ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 0.030.750.090.310.170.010.010.251.47
✘ ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine2 (sim) 0.020.750.080.330.160.010.010.241.46
✘ ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3 (sim) 0.020.840.080.360.190.020.010.261.51
✘ ThermoSysPro.Examples.SimpleExamples.TestSwitchValve (sim) 0.020.970.080.510.220.010.010.221.64
✘ ThermoSysPro.Examples.SimpleExamples.TestTank (sim) 0.131.040.120.550.260.010.010.201.83
✘ ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim) 0.040.640.080.300.150.010.010.171.36
✘ ThermoSysPro.Examples.SimpleExamples.TestVolumeATh (sim) 0.110.940.120.500.210.010.010.201.72
✘ ThermoSysPro.Examples.SimpleExamples.TestVolumes (sim) 0.251.110.080.530.290.020.020.252.05
✘ ThermoSysPro.Examples.SimpleExamples.TestVolumes1 (sim) 0.231.090.080.510.290.030.020.252.04
✘ ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 2.061.080.080.550.270.020.010.233.76
✘ ThermoSysPro.Examples.SimpleExamples.TestWirelessSensor (sim) 0.141.040.090.520.280.020.010.211.85
✘ ThermoSysPro.Fluid.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip (sim) 240.1016.270.111.424.930.880.658.39257.34
✘ ThermoSysPro.Fluid.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation (sim) 205.6916.370.121.404.740.960.818.46222.92
✘ ThermoSysPro.Fluid.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC (sim) 6.7417.840.091.196.590.990.438.6425.31
✘ ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant 0.005.290.131.213.470.510.110.006.03
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_1 (sim) 0.022.790.531.940.220.010.010.604.03
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_2 (sim) 0.022.770.571.920.220.010.030.594.01
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_3 (sim) 0.102.760.412.060.360.020.020.303.93
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_4 (sim) 0.072.250.101.350.240.010.010.633.06
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestStaticCentrifugalPump (sim) 0.062.740.451.890.270.010.010.553.87
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding (sim) 71.654.770.090.712.260.240.171.3877.04
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.NegativeFlow (sim) 74.866.220.080.752.290.200.112.8881.74
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow (sim) 102.737.470.080.822.360.240.173.88110.88
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicCondenser (sim) 0.102.460.081.110.830.040.020.473.20
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicOnePhaseFlowShell (sim) 0.011.560.080.520.600.030.020.372.20
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicTwoPhaseFlowPipe (sim) 0.011.830.080.580.530.090.040.592.50
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.TestStaticCondenser (sim) 0.002.750.131.140.570.020.060.963.62
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestBend (sim) 0.012.280.371.390.230.010.050.603.29
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestCheckValve (sim) 0.011.200.230.470.160.010.010.552.08
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestControlValve (sim) 0.011.750.461.210.170.010.040.332.88
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestDiaphragm (sim) 0.012.130.291.330.210.030.030.523.08
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestDynamicCheckValve (sim) 0.671.330.350.610.160.010.010.542.97
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestDynamicReliefValve (sim) 2.661.950.071.240.440.010.010.255.26
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestLumpedStraightPipe (sim) 0.092.690.511.530.470.010.050.613.99
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestPipePressureLoss (sim) 0.012.770.441.930.160.010.060.613.88
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestSwitchValve (sim) 0.041.480.100.620.310.010.010.522.24
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestThreeWayValve (sim) 0.041.110.340.530.290.010.010.272.11
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.SolarCollector.TestFresnelField (sim) 2.847.220.091.512.070.290.173.1810.77
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.SteamTurbine.TestStodolaTurbine (sim) 0.022.620.351.750.160.020.060.633.70
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestDynamicDrum (sim) 12.453.270.080.901.020.100.111.1416.39
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestMixer3 (sim) 0.052.740.191.750.350.020.030.603.63
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestPressurizer (sim) 0.442.240.191.140.490.020.020.573.49
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestSplitter3 (sim) 0.032.090.341.160.420.010.030.473.14
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestStaticDrum3 (sim) 0.014.130.131.471.100.080.041.444.86
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestSteamDryer (sim) 0.042.000.171.130.460.010.020.372.83
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestTank (sim) 0.142.230.371.230.420.010.010.563.35
✘ ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestVolumeATh (sim) 0.101.870.361.080.540.010.010.232.96
✘ ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 1.9516.110.252.306.551.200.445.6119.01
✘ ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 0.0215.650.092.216.261.210.515.4716.47
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestAirHumidity (sim) 0.021.490.091.040.220.010.010.212.24
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestBend (sim) 0.011.330.120.890.210.010.010.212.11
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestCHPEngineBarkantineSystem (sim) 0.111.550.090.530.730.020.020.252.34
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestCentrifugalPump1 (sim) 0.021.300.090.830.270.010.010.191.99
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestCheckValve (sim) 0.251.370.120.640.440.020.020.252.33
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiaphragm (sim) 0.021.010.090.570.220.010.010.211.69
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_DynamicOnePhaseFlowPipe (sim) 0.091.900.090.650.750.070.030.402.68
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_DynamicPlateHeatExchanger (sim) 0.381.390.090.620.390.060.030.292.46
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_DynamicTwoPhaseFlowPipe (sim) 0.052.820.090.691.100.200.070.763.61
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_VolumeA (sim) 0.021.040.150.520.290.010.010.201.78
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicCheckValve (sim) 0.710.850.120.500.160.010.010.182.34
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicCondenser (sim) 0.082.710.110.661.310.070.050.633.50
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicDrum (sim) 0.192.080.080.590.840.090.040.532.91
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicDrum_CC (sim) 12.552.640.080.681.070.140.070.6915.88
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicFlueGasesMultiFluidHeatExchanger (sim) 0.381.640.090.620.530.050.020.422.68
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicMultiFluidHeatExchanger (sim) 0.571.640.080.570.700.040.030.302.88
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicMultiFluidHeatExchangerShell (sim) 0.521.150.080.570.220.040.030.292.33
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim) 0.651.850.080.610.740.040.020.443.12
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicPlateHeatExchanger (sim) 0.421.550.080.590.510.090.030.332.63
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicReliefValve (sim) 0.181.160.080.510.330.020.020.291.95
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim) 0.013.290.080.711.010.270.131.183.94
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicTwoPhaseFlowRiser (sim) 0.112.330.080.550.500.090.041.163.11
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 8.005.250.080.782.310.240.201.7213.95
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicWaterHeatingOnePipe (sim) 2.894.010.080.841.750.170.211.057.57
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicWaterSteamMultiFluidHeatExchanger (sim) 0.462.960.081.200.920.060.070.714.09
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestFixedPowerHeatExchanger (sim) 0.011.220.280.920.080.010.040.172.12
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestFresnelField (sim) 3.645.810.091.092.520.320.361.5310.14
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestGasTurbine (sim) 0.121.490.200.940.180.020.050.302.39
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestIdealCheckValve (sim) 0.171.640.410.640.510.020.080.402.82
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestIdealSwitchValve (sim) 0.032.270.211.180.320.010.060.703.20
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestInvSingularPressureLoss (sim) 0.011.920.140.980.340.010.040.552.77
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestJunctions1 (sim) 0.081.790.210.870.600.020.010.292.67
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestJunctions2 (sim) 0.081.180.080.560.390.020.010.201.97
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestJunctions3 (sim) 0.351.330.090.540.530.020.010.232.38
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestJunctions4 (sim) 0.030.990.090.500.310.010.010.171.68
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestLoopBreaker (sim) 0.021.010.090.520.330.010.010.151.66
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestMassFlowMultiplier (sim) 0.030.990.110.460.340.010.010.171.68
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestNTUWaterHeater0 (sim) 0.061.320.080.540.540.020.010.212.03
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestPressurizer (sim) 0.001.310.090.590.460.020.010.231.95
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestRefP (sim) 0.021.160.090.540.400.010.010.201.79
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestRefP1 (sim) 0.041.150.110.530.390.010.010.201.94
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestSensors (sim) 0.021.200.080.570.330.010.010.281.95
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleDynamicCondenser (sim) 0.381.310.080.490.530.020.010.262.35
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleDynamicCondenser1 (sim) 0.071.550.080.610.520.020.020.382.30
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases (sim) 0.031.290.090.590.470.010.010.201.99
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleStaticCondenser (sim) 0.030.820.130.520.090.010.010.191.70
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestSingularPressureLoss (sim) 0.010.820.080.500.120.010.010.201.51
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticAerocondenser (sim) 0.061.320.080.540.480.010.010.272.04
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticCentrifugalPump1 (sim) 0.010.850.090.520.120.010.010.191.58
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticCondenser (sim) 0.061.340.080.550.530.020.010.232.07
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticCondenserHEI (sim) 0.071.480.080.640.580.020.020.232.21
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticDrum1 (sim) 0.001.040.090.600.230.010.010.181.80
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticDrum2 (sim) 0.041.040.110.570.270.010.010.181.80
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticExchangerDTorWorEff (sim) 0.031.060.090.540.270.010.010.221.89
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticExchangerKS (sim) 0.130.960.100.530.230.010.010.181.79
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticFan 0.000.990.120.540.360.090.000.001.64
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticPlateHeatExchanger (sim) 0.010.760.090.500.050.010.010.181.45
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticWallFlueGasesExchanger (sim) 0.220.970.080.510.180.020.020.241.85
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestSteamDryer1 (sim) 0.031.310.080.600.490.010.010.201.96
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestSteamDryer2 (sim) 0.041.270.090.610.470.010.010.181.97
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestSteamEngine (sim) 0.010.990.150.580.140.010.010.251.73
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestSteamExtractionSplitter (sim) 0.041.040.130.530.310.010.010.191.90
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 0.001.130.090.580.230.020.010.291.92
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestStodolaTurbine2 (sim) 0.020.930.090.540.110.010.010.261.70
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestSwitchValve (sim) 0.041.170.090.590.330.010.010.232.02
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestTank (sim) 0.151.300.090.550.430.020.010.292.17
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestTankHorizontal (sim) 0.241.570.080.530.600.030.020.392.48
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestThreeWayValve (sim) 0.031.110.100.610.290.010.010.181.83
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestVolumeA (sim) 4.581.300.110.590.430.020.010.256.63
✘ ThermoSysPro.Fluid.Examples.SimpleExamples.TestVolumeI (sim) 0.581.320.090.590.430.030.030.242.62
✘ ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test1_IF97 (sim) 0.871.760.261.140.230.020.020.343.55
✘ ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test1_polynomial (sim) 0.002.330.081.300.280.020.060.673.00
✘ ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test2_IF97 (sim) 0.091.680.391.050.220.020.010.382.76
✘ ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test2_polynomial (sim) 0.001.750.300.750.220.010.100.662.65
✘ ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test3_IF97 (sim) 0.491.970.231.020.280.020.020.643.28
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_T (sim) 0.000.330.400.290.000.000.000.031.37
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_d (sim) 0.000.740.140.700.000.000.000.031.58
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_h (sim) 0.011.140.360.740.080.010.050.272.16
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_p (sim) 0.011.080.170.660.080.010.020.311.91