Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=100 tolerance=1e-06 numberOfIntervals=100 stepSize=1 Regular simulation: ./TransiEnt_TransiEnt.Producer.Electrical.Wind.Check.TestWindturbine_SI_DF -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.021926s reading init.xml | | | | | | 0.00164525s reading info.xml | | | | | | 0.000147848s [ 0.6%] pre-initialization | | | | | | 0.0250067s [ 94.6%] initialization | | | | | | 1.302e-06s [ 0.0%] steps | | | | | | 0.000352589s [ 1.3%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000150574s [ 0.6%] event-handling | | | | | | 0.00011632s [ 0.4%] overhead | | | | | | 0.000665052s [ 2.5%] simulation | | | | | | 0.0264404s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 2 time events | | | | | solver: dassl | | | | | | 377 steps taken | | | | | | 487 calls of functionODE | | | | | | 116 evaluations of jacobian | | | | | | 13 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000258289s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.