Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=7200 tolerance=1e-06 numberOfIntervals=2500 stepSize=2.88 Regular simulation: ./TransiEnt_TransiEnt.Producer.Electrical.Conventional.Components.Check.CheckNonlinearThreeStatePlant_SecondaryControl -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.019626s reading init.xml | | | | | | 0.0014293s reading info.xml | | | | | | 0.000154711s [ 0.5%] pre-initialization | | | | | | 0.0280347s [ 81.7%] initialization | | | | | | 2.195e-06s [ 0.0%] steps | | | | | | 0.000975614s [ 2.8%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000710715s [ 2.1%] event-handling | | | | | | 0.00109266s [ 3.2%] overhead | | | | | | 0.00333853s [ 9.7%] simulation | | | | | | 0.0343091s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 3 time events | | | | | solver: dassl | | | | | | 604 steps taken | | | | | | 1025 calls of functionODE | | | | | | 341 evaluations of jacobian | | | | | | 13 error test failures | | | | | | 77 convergence test failures | | | | | | 0.00025639s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.