Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer_Autosizing.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0009227/0.0009227, allocations: 72.19 kB / 9.903 MB, free: 0.7852 MB / 10.45 MB Notification: Performance of NFInstanceAPI.mkTop(): time 0.0016/0.002523, allocations: 435.8 kB / 10.33 MB, free: 368 kB / 10.45 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0014/0.0014, allocations: 161.1 kB / 11.23 MB, free: 2.941 MB / 13.93 MB Notification: Performance of NFInstanceAPI.mkTop(): time 0.001638/0.003038, allocations: 463.6 kB / 11.68 MB, free: 2.484 MB / 13.93 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.9839/0.9839, allocations: 177.2 MB / 189.6 MB, free: 5.316 MB / 186.7 MB Notification: Performance of NFInstanceAPI.mkTop(): time 0.1008/1.085, allocations: 53.66 MB / 243.2 MB, free: 15.59 MB / 250.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/package.mo): time 2.444/2.444, allocations: 446.7 MB / 0.6745 GB, free: 6.227 MB / 0.6511 GB Notification: Performance of NFInstanceAPI.mkTop(): time 0.2694/2.713, allocations: 145.9 MB / 0.817 GB, free: 4.234 MB / 0.7917 GB " [Timeout remaining time 177] Using package Buildings with version 15.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer_Autosizing,tolerance=1e-07,outputFormat="mat",numberOfIntervals=480,variableFilter="time|flo.sou.TAir|flo.eas.TAir|flo.nor.TAir|flo.wes.TAir|flo.cor.TAir|hvac.TSetRoo.setPoiHea.y|hvac.TSetRoo.setPoiCoo.y|hvac.fanSup.y|hvac.VAVBox.[0-9,]+..vav.y_actual|hvac.damOut.y|hvac.VAVBox.[0-9,]+..TSup|hvac.res.EFan|hvac.res.EHea|hvac.res.ECoo",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer_Autosizing") translateModel(Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer_Autosizing,tolerance=1e-07,outputFormat="mat",numberOfIntervals=480,variableFilter="time|flo.sou.TAir|flo.eas.TAir|flo.nor.TAir|flo.wes.TAir|flo.cor.TAir|hvac.TSetRoo.setPoiHea.y|hvac.TSetRoo.setPoiCoo.y|hvac.fanSup.y|hvac.VAVBox.[0-9,]+..vav.y_actual|hvac.damOut.y|hvac.VAVBox.[0-9,]+..TSup|hvac.res.EFan|hvac.res.EHea|hvac.res.ECoo",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer_Autosizing") [Timeout 300] OMC exited with status 134 while running: translateModel(Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer_Autosizing,tolerance=1e-07,outputFormat="mat",numberOfIntervals=480,variableFilter="time|flo.sou.TAir|flo.eas.TAir|flo.nor.TAir|flo.wes.TAir|flo.cor.TAir|hvac.TSetRoo.setPoiHea.y|hvac.TSetRoo.setPoiCoo.y|hvac.fanSup.y|hvac.VAVBox.[0-9,]+..vav.y_actual|hvac.damOut.y|hvac.VAVBox.[0-9,]+..TSup|hvac.res.EFan|hvac.res.EHea|hvac.res.ECoo",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer_Autosizing") Created ZeroMQ Server. Dumped server port in file: /tmp/openmodelica.hudson.port.ddb908e35304456fb5b2ab3fabc4fadcERROREXT: deleting checkpoint called with id:'SimCodeMain.translateModel' but top of checkpoint stack has id:'NFCall:checkMatchingFunctions' Current Stack: 1 NFCall:checkMatchingFunctions message:Error: Internal error Instantiation of Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer_Autosizing failed with no error message. Notification: Performance of FrontEnd: time 0.007983/0.9906, allocations: 3.986 MB / 1.341 GB, free: 4.453 MB / 1.151 GB 0 SimCodeMain.translateModel message:Notification: Performance of FrontEnd - loaded program: time 1.734e-06/1.734e-06, allocations: 0 / 0.8184 GB, free: 2.809 MB / 0.7917 GB Notification: Performance of FrontEnd - Absyn->SCode: time 1.541e-05/1.714e-05, allocations: 2.312 kB / 0.8184 GB, free: 2.805 MB / 0.7917 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer_Autosizing): time 0.7278/0.7279, allocations: 413.9 MB / 1.223 GB, free: 7.137 MB / 1.042 GB Notification: Performance of NFInst.instExpressions: time 0.1405/0.8684, allocations: 87.21 MB / 1.308 GB, free: 6.965 MB / 1.12 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.03521/0.9036, allocations: 1.178 MB / 1.309 GB, free: 5.777 MB / 1.12 GB Notification: Performance of NFTyping.typeComponents: time 0.02248/0.9261, allocations: 7.094 MB / 1.316 GB, free: 14.63 MB / 1.135 GB Notification: Performance of NFTyping.typeBindings: time 0.05653/0.9826, allocations: 22.07 MB / 1.337 GB, free: 8.441 MB / 1.151 GB Error: Internal error Instantiation of Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer_Autosizing failed with no error message. Notification: Performance of FrontEnd: time 0.007983/0.9906, allocations: 3.986 MB / 1.341 GB, free: 4.453 MB / 1.151 GB Aborted (core dumped) [Calling os._exit(0), Time elapsed: 8.141474553383887]