Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_latest_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0009447/0.0009447, allocations: 72.19 kB / 9.903 MB, free: 0.7852 MB / 10.45 MB Notification: Performance of NFInstanceAPI.mkTop(): time 0.00108/0.002025, allocations: 435.8 kB / 10.33 MB, free: 368 kB / 10.45 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0007008/0.0007008, allocations: 161.1 kB / 11.23 MB, free: 2.941 MB / 13.93 MB Notification: Performance of NFInstanceAPI.mkTop(): time 0.000914/0.001615, allocations: 463.6 kB / 11.68 MB, free: 2.484 MB / 13.93 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.9147/0.9147, allocations: 177.2 MB / 189.6 MB, free: 5.309 MB / 186.7 MB Notification: Performance of NFInstanceAPI.mkTop(): time 0.08833/1.003, allocations: 53.66 MB / 243.2 MB, free: 15.58 MB / 250.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/package.mo): time 2.39/2.39, allocations: 446.7 MB / 0.6745 GB, free: 6.215 MB / 0.6511 GB Notification: Performance of NFInstanceAPI.mkTop(): time 0.2425/2.632, allocations: 145.9 MB / 0.817 GB, free: 4.215 MB / 0.7917 GB " [Timeout remaining time 177] Using package Buildings with version 15.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|TSet.y|TOut.y|TVol.T|THeaOut.T|eleHea.Q_flow|eleHea.P",fileNamePrefix="Buildings_latest_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater") translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|TSet.y|TOut.y|TVol.T|THeaOut.T|eleHea.Q_flow|eleHea.P",fileNamePrefix="Buildings_latest_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater") [Timeout 300] OMC exited with status 134 while running: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|TSet.y|TOut.y|TVol.T|THeaOut.T|eleHea.Q_flow|eleHea.P",fileNamePrefix="Buildings_latest_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater") Created ZeroMQ Server. Dumped server port in file: /tmp/openmodelica.hudson.port.37fff2aeb14d4dcab06d5794ce5d769fERROREXT: deleting checkpoint called with id:'SimCodeMain.translateModel' but top of checkpoint stack has id:'NFCall:checkMatchingFunctions' Current Stack: 1 NFCall:checkMatchingFunctions message:Error: Internal error Instantiation of Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater failed with no error message. Notification: Performance of FrontEnd: time 0.0006128/0.1942, allocations: 327.2 kB / 0.9901 GB, free: 2.281 MB / 0.9636 GB 0 SimCodeMain.translateModel message:Notification: Performance of FrontEnd - loaded program: time 1.814e-06/1.814e-06, allocations: 0 / 0.8184 GB, free: 2.797 MB / 0.7917 GB Notification: Performance of FrontEnd - Absyn->SCode: time 3.004e-05/3.185e-05, allocations: 2.312 kB / 0.8184 GB, free: 2.793 MB / 0.7917 GB Notification: Performance of NFInst.instantiate(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater): time 0.1633/0.1634, allocations: 158.3 MB / 0.973 GB, free: 3.891 MB / 0.948 GB Notification: Performance of NFInst.instExpressions: time 0.02001/0.1834, allocations: 12.88 MB / 0.9856 GB, free: 6.977 MB / 0.9636 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.002272/0.1857, allocations: 130.9 kB / 0.9857 GB, free: 6.848 MB / 0.9636 GB Notification: Performance of NFTyping.typeComponents: time 0.003492/0.1891, allocations: 1.683 MB / 0.9873 GB, free: 5.156 MB / 0.9636 GB Notification: Performance of NFTyping.typeBindings: time 0.004446/0.1936, allocations: 2.541 MB / 0.9898 GB, free: 2.602 MB / 0.9636 GB Error: Internal error Instantiation of Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater failed with no error message. Notification: Performance of FrontEnd: time 0.0006128/0.1942, allocations: 327.2 kB / 0.9901 GB, free: 2.281 MB / 0.9636 GB Aborted (core dumped) [Calling os._exit(0), Time elapsed: 5.975106074474752]