Environment - simulationEnvironment: SPAWNPATH = /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x//Resources/bin/Spawn-light-0.5.0-ab07bde9bb/linux64/bin:/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x//Resources/bin/Spawn-light-0.6.0-9f1b36b00b/linux64/bin startTime=1.6848e+07 stopTime=1.728e+07 tolerance=1e-07 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Summer -abortSlowSimulation -alarm=240 -emit_protected -ignoreHideResult -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.17 23:14 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 07/15/2006 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848172.800000 | | | | ((hvac.VAVBox[1].VSup_flow >= 0.0), hvac.VAVBox[1].VSup_flow=-4.824916493364853e-16) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -4.82492e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848172.800000 | | | | ((hvac.VAVBox[2].VSup_flow >= 0.0), hvac.VAVBox[2].VSup_flow=-7.350466154919166e-17) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -7.35047e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848172.800000 | | | | ((hvac.VAVBox[3].VSup_flow >= 0.0), hvac.VAVBox[3].VSup_flow=-4.824916493364853e-16) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -4.82492e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848172.800000 | | | | ((hvac.VAVBox[4].VSup_flow >= 0.0), hvac.VAVBox[4].VSup_flow=-7.350466154919166e-17) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -7.35047e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848172.800000 | | | | ((hvac.VAVBox[5].VSup_flow >= 0.0), hvac.VAVBox[5].VSup_flow=-6.364749304935006e-16) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -6.36475e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 16849036.800000 | | | | ((hvac.fanSup.etaHyd >= 0.0), hvac.fanSup.etaHyd=-4.892327539912566e-21) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -4.89233e-21" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16849036.800000 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0), hvac.fanSup.heaDis.etaHyd=-1.20604746344021e-16) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -1.20605e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 16916428.800000 | | | | ((hvac.cooCoi.SHR >= 0.0 and hvac.cooCoi.SHR <= 1.0), hvac.cooCoi.SHR=-9.294810713972681e-09) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.SHR <= 1.0, has value: -9.29481e-09" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.pumCooCoi.etaHyd >= 0.0), hvac.pumCooCoi.etaHyd=-1.083611204876781e-24) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.etaHyd, has value: -1.08361e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.pumCooCoi.heaDis.etaHyd >= 0.0), hvac.pumCooCoi.heaDis.etaHyd=-1.565772104033723e-22) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.heaDis.etaHyd, has value: -1.56577e-22" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16916774.400000 | | | | ((hvac.fanSup.eff.yMot >= 0.0), hvac.fanSup.eff.yMot=-1.890129178228327e-176) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -1.89013e-176" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:117:3-118:81:writable] | | | | The following assertion has been violated at time 16916774.400000 | | | | ((hvac.pumCooCoi.m_flow >= 0.0 and hvac.pumCooCoi.m_flow <= 1e5), hvac.pumCooCoi.m_flow=-1.643159713340507e-12) --> "Variable violating min/max constraint: 0.0 <= hvac.pumCooCoi.m_flow <= 1e5, has value: -1.64316e-12" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16916774.400000 | | | | ((hvac.pumCooCoi.eff.yMot >= 0.0), hvac.pumCooCoi.eff.yMot=-1.135945136661961e-122) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.eff.yMot, has value: -1.13595e-122" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.122604s reading init.xml | | | | | | 0.0113318s reading info.xml | | | | | | 0.00248874s [ 0.0%] pre-initialization | | | | | | 5.43036s [ 15.8%] initialization | | | | | | 0.00452337s [ 0.0%] steps | | | | | | 1.45033s [ 4.2%] solver (excl. callbacks) | | | | | | 0.00613788s [ 0.0%] creating output-file | | | | | | 1.73863s [ 5.1%] event-handling | | | | | | 0.0238562s [ 0.1%] overhead | | | | | | 25.6156s [ 74.7%] simulation | | | | | | 34.272s [100.0%] total | | | | | events | | | | | | 41 state events | | | | | | 730 time events | | | | | solver: dassl | | | | | | 72771 steps taken | | | | | | 134662 calls of functionODE | | | | | | 61486 evaluations of jacobian | | | | | | 2753 error test failures | | | | | | 15461 convergence test failures | | | | | | 23.9049s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 29.13sec EnergyPlus Completed Successfully.