Environment - simulationEnvironment: startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_12_Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.ConventionalWinter -abortSlowSimulation -alarm=240 -s gbode -gbm=radauIIA3 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zonAHUOpt.sinZonFlo.ports[2].m_flow >= -1e5 and zonAHUOpt.sinZonFlo.ports[2].m_flow <= 0.0)) --> "Variable violating min/max constraint: -1e5 <= zonAHUOpt.sinZonFlo.ports[2].m_flow <= 0.0, has value: 0.0509126" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zonAHUCon.sinZonFlo.ports[2].m_flow >= -1e5 and zonAHUCon.sinZonFlo.ports[2].m_flow <= 0.0)) --> "Variable violating min/max constraint: -1e5 <= zonAHUCon.sinZonFlo.ports[2].m_flow <= 0.0, has value: 0.0509126" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Interfaces/PartialTwoPortTransport.mo:34:3-36:69:writable] | | | | The following assertion has been violated at time 288000.000000 | | | | ((zonAHUOpt.hvac.ideVal.preMasFlo.m_flow >= 0.0 and zonAHUOpt.hvac.ideVal.preMasFlo.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= zonAHUOpt.hvac.ideVal.preMasFlo.m_flow <= 1e5, has value: -2.29589e-41" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 547200.000000 | | | | ((zonAHUOpt.hvac.cooCoi.m1_flow >= 0.0 and zonAHUOpt.hvac.cooCoi.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= zonAHUOpt.hvac.cooCoi.m1_flow <= 1e5, has value: -1.14794e-41" LOG_STATS | info | gbode (single-rate integration): radauIIA3 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 9.6522e-05s [ 0.0%] pre-initialization | | | | | | 0.0403072s [ 4.0%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.00390467s [ 0.4%] creating output-file | | | | | | 0.0186179s [ 1.8%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.951838s [ 93.8%] simulation | | | | | | 1.01476s [100.0%] total | | | | | events | | | | | | 29 state events | | | | | | 67 time events | | | | | solver: gbode | | | | | | 1376 steps taken | | | | | | 7415 calls of functionODE | | | | | | 185 evaluations of jacobian | | | | | | 11 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.