startTime=0 stopTime=200 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.08 wasm-jit simulation: simulate(Buildings.Templates.Components.Validation.Valves,startTime=0,stopTime=200,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|modThr.bus.y|modThr.bus.y_actual|modThr.m_flow|modThr.portByp_a.m_flow|modThr.m_flow_nominal|modTwo.bus.y|modTwo.bus.y_actual|modTwo.m_flow|modTwo.m_flow_nominal|twoThr.bus.y1|twoThr.bus.y1_actual|twoThr.m_flow|twoThr.portByp_a.m_flow|twoThr.m_flow_nominal|twoTwo.bus.y1|twoTwo.bus.y1_actual|twoTwo.m_flow|twoTwo.m_flow_nominal",fileNamePrefix="Buildings_latest_Buildings.Templates.Components.Validation.Valves",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") Simulation execution failed for model: Buildings.Templates.Components.Validation.Valves LOG_STDOUT | warning | Sparsity pattern for non-linear system 0 is not regular. This indicates that something went wrong during sparsity pattern generation. Removing sparsity pattern and disabling NLS scaling. LOG_STDOUT | warning | Sparsity pattern for non-linear system 1 is not regular. This indicates that something went wrong during sparsity pattern generation. Removing sparsity pattern and disabling NLS scaling. LOG_ASSERT | warning | Homotopy algorithm did not converge. | | | | The maximum number of lambda steps is reached (600). | | | | You can change the maximum number of lambda steps with: | | | | -homMaxLambdaSteps= | | | | You can also try to influence the step size tau with the following flags: | | | | -homTauDecFac= | | | | -homTauDecFacPredictor= | | | | -homTauIncFac= | | | | -homTauIncThreshold= | | | | -homTauMax= | | | | -homTauMin= | | | | -homTauStart= | | | | or you can also set the threshold for accepting the current bending with: | | | | -homAdaptBend= | | | | You can also try to use another backtrace stategy in the corrector step with: | | | | -homBacktraceStrategy= | | | | You can use -lv=LOG_INIT_HOMOTOPY,LOG_NLS_HOMOTOPY to get more information. LOG_ASSERT | info | The homotopy algorithm is started again with opposing start direction. LOG_ASSERT | warning | Homotopy algorithm did not converge. | | | | The maximum number of lambda steps is reached (600). | | | | You can change the maximum number of lambda steps with: | | | | -homMaxLambdaSteps= | | | | You can also try to influence the step size tau with the following flags: | | | | -homTauDecFac= | | | | -homTauDecFacPredictor= | | | | -homTauIncFac= | | | | -homTauIncThreshold= | | | | -homTauMax= | | | | -homTauMin= | | | | -homTauStart= | | | | or you can also set the threshold for accepting the current bending with: | | | | -homAdaptBend= | | | | You can also try to use another backtrace stategy in the corrector step with: | | | | -homBacktraceStrategy= | | | | You can use -lv=LOG_INIT_HOMOTOPY,LOG_NLS_HOMOTOPY to get more information. LOG_ASSERT | debug | Solving non-linear system 120 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | info | simulation terminated by an assertion at initialization