startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 wasm-jit simulation: simulate(Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctSnapActing.Validation.Controller,startTime=0,stopTime=86400,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|duaDucCon.TZon|duaDucCon.TCooSet|duaDucCon.THeaSet|duaDucCon.TDis|duaDucCon.TColSup|duaDucCon.THotSup|duaDucCon.u1Win|duaDucCon.u1Occ|duaDucCon.uOpeMod|duaDucCon.ppmCO2|duaDucCon.VColDucDis_flow|duaDucCon.VHotDucDis_flow|duaDucCon.oveFloSet|duaDucCon.oveCooDamPos|duaDucCon.oveHeaDamPos|duaDucCon.u1CooAHU|duaDucCon.u1HeaAHU|duaDucCon.VSet_flow|duaDucCon.yCooDam|duaDucCon.yHeaDam|duaDucCon.yZonCooTemResReq|duaDucCon.yColDucPreResReq|duaDucCon.yLowFloAla|duaDucCon.yColFloSenAla|duaDucCon.yColLeaDamAla",fileNamePrefix="Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctSnapActing.Validation.Controller",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not duaDucCon.ala.truDel5.y)) --> "Warning: the hot-duct damper is leaking." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not duaDucCon.ala.truDel3.y)) --> "Warning: the cold-duct damper is leaking." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 12080.000000 | | | | ((not duaDucCon.ala.truDel4.y)) --> "Warning: hot-duct airflow sensor should be calibrated." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 12080.000000 | | | | ((not duaDucCon.ala.truDel2.y)) --> "Warning: cold-duct airflow sensor should be calibrated." LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 3.8141e-05s [ 0.1%] pre-initialization | | | | | | 0.000161641s [ 0.3%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.0108851s [ 21.4%] solver (excl. callbacks) | | | | | | 0.00126492s [ 2.5%] creating output-file | | | | | | 0.0125797s [ 24.7%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0259411s [ 51.0%] simulation | | | | | | 0.0508706s [100.0%] total | | | | | events | | | | | | 39 state events | | | | | | 739 time events | | | | | solver: dassl | | | | | | 11116 steps taken | | | | | | 12873 calls of functionODE | | | | | | 9480 evaluations of jacobian | | | | | | 45 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00724645s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.