Dynawo_dev test using OpenModelica

Total Frontend Backend SimCode Templates Compilation Simulation Verification
81 79 71 71 71 71 66 53

Test started: 2026-10-05 15:55:55
Total time taken: 0:27:01
System info: ryzen-9950x: AMD Ryzen 9 9950X3D 16-Core Processor, 124 GB RAM, Ubuntu 26.04.1 LTS

OpenModelica Version: v1.28.0-dev.1274+g0eca3e7970.rust
OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
19357df2026-10-05 10:07:02 +0200Martin SjölundRun models sharing a port one at a time

Tested Library: Dynawo_dev 1.8.0

{
 "path": "dynawo/sources/Models/Modelica/Dynawo",
 "sha": "6c7e694ab654296b539ebce5a5f9871c8b3a1852",
 "support": "noSupport",
 "uses": {
  "Modelica": "3.2.3"
 },
 "version": "1.8.0-master",
 "wasm": {
  "2": {
   "generation": 1,
   "sha256": "931c8be42ae263d01d6156ca8de84b45a71c8ee74ea41fc753a27ad0afbd9de5",
   "systemLibraries": [
    "libc"
   ],
   "zipfile": "https://libraries.openmodelica.org/precompiled/wasm32-wasip1/omc-1/Dynawo-wasm32-wasip1-89b54733ef1fec36.zip"
  }
 },
 "zipfile": "https://github.com/dynawo/dynawo/archive/6c7e694ab654296b539ebce5a5f9871c8b3a1852.zip"
}

BuildModel time limit: 660s
Simulation time limit: 240s
Default tolerance: 1e-06
Default number of intervals: 2500
Optimization level: Tool default

Reference Files: https://github.com/dynawo/dynawo (6c7e694ab654296b539ebce5a5f9871c8b3a1852)

CommitDateAuthorSummary
6c7e694ab652026-10-05 11:27:36 +0200Erwan Guichard#4202 Missing parameters added, .log files updated

Verified using: v1.28.0-dev.1244+gd409060.cmake (diffSimulationResults)

Flags:
setCommandLineOptions("--simCodeTarget=wasm-jit")
setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
setCommandLineOptions("--allowNonStandardModelica=implicitParameterStartAttribute,illegalConditionalContext");
Config:
{
 "extraCustomCommands": [
  "setCommandLineOptions(\"--allowNonStandardModelica=implicitParameterStartAttribute,illegalConditionalContext\");"
 ],
 "library": "Dynawo",
 "libraryVersion": "master",
 "libraryVersionNameForTests": "dev",
 "referenceFileExtension": "csv",
 "referenceFileNameDelimiter": ".",
 "referenceFiles": {
  "destination": "ReferenceFiles/Dynawo",
  "git-directory": "dynawo/sources/Models/Modelica/Dynawo/Examples/references",
  "giturl": "https://github.com/dynawo/dynawo"
 },
 "referenceFinalDot": "_res."
}

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

ModelVerifiedSimulateTotal buildModelParsingFrontendBackendSimCodeTemplatesCompileTotal Execution
Dynawo.Examples.BESS.WECC.BESSCurrentSource (sim)0.05 (6 verified)0.130.340.220.070.110.020.020.111.53
Dynawo.Examples.BESS.WECC.BESSCurrentSourceExternalPCS (sim)0.05 (6 verified)0.160.420.190.100.140.030.020.131.59
Dynawo.Examples.BESS.WECC.BESSCurrentSourceNoPPC (sim)0.05 (6 verified)0.090.250.160.050.080.020.010.091.28
Dynawo.Examples.ENTSOE.TestCase1 (sim)0.01 (4 verified)0.030.250.200.050.080.020.010.091.14
Dynawo.Examples.ENTSOE.TestCase2 (sim)0.01 (4 verified)0.040.230.170.060.060.010.010.081.11
Dynawo.Examples.ENTSOE.TestCase3 (sim)0.01 (4 verified)0.120.280.170.050.100.020.010.101.31
Dynawo.Examples.GridCodeSimulations.RunSimulations 0.000.970.170.820.150.000.000.001.70
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI2Xcca 0.000.130.210.080.040.000.000.000.98
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI2Xccb 0.000.130.230.090.040.000.000.000.99
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI5 0.000.130.170.090.040.000.000.000.97
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI6 0.000.130.210.090.040.000.000.000.96
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI7QMax 0.000.120.220.080.040.000.000.000.98
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI7QMin 0.000.120.170.080.040.000.000.000.95
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI10 0.000.130.210.090.040.000.000.001.08
Dynawo.Examples.GridForming.EpriSmib (sim)0.01 (4 verified)0.020.210.220.040.070.020.010.071.03
Dynawo.Examples.GridForming.GridForming (sim)0.01 (10 verified)1.470.420.220.060.210.030.020.102.82
Dynawo.Examples.HVDC.HVDC (sim)0.35 (3/9 failed)1.050.350.170.070.100.020.020.133.01
Dynawo.Examples.IEEE14.TestCases.IEEE14CLA 0.000.520.220.070.180.020.020.231.33
Dynawo.Examples.IEEE14.TestCases.IEEE14DisconnectLine (sim)0.01 (18 verified)0.010.390.170.070.180.020.020.101.22
Dynawo.Examples.IEEE14.TestCases.IEEE14NoEvent (sim)0.01 (18 verified)0.010.400.170.070.180.020.020.101.30
Dynawo.Examples.IEEE57.TestCases.IEEE57DisconnectLine (sim)0.01 (1/3 failed)2.751.340.170.270.660.070.060.294.99
Dynawo.Examples.IEEE57.TestCases.IEEE57HvdcPsDisconnectLine (sim)0.01 (2/4 failed)0.061.350.210.260.650.070.050.312.33
Dynawo.Examples.IEEE57.TestCases.IEEE57NoEvent (sim)0.01 (5/18 failed)3.201.470.170.240.750.100.070.315.53
Dynawo.Examples.IEEE118.TestCases.IEEE118NoEvent (sim)0.01 (13 verified)0.435.330.231.002.750.320.201.056.71
Dynawo.Examples.IllustrativeExamples.DynaFlow.CoordinatedVControl (sim)0.01 (7 verified)0.010.110.170.030.030.010.010.040.98
Dynawo.Examples.IllustrativeExamples.DynaFlow.PhaseShifterTransformer (sim)0.01 (6 verified)0.000.100.170.020.030.010.010.030.96
Dynawo.Examples.InertialGrid.DoubleInertialGrid (sim)0.05 (2 verified)0.470.170.160.030.070.010.010.061.43
Dynawo.Examples.LoadFrequencyDependent.LoadAlphaBetaFrequencyDependent (sim)0.02 (2/3 failed)0.010.110.180.020.030.010.010.050.97
Dynawo.Examples.LoadFrequencyDependent.LoadZIPFrequencyDependent (sim)0.01 (3 verified)0.010.130.180.020.040.010.010.051.01
Dynawo.Examples.Nordic.TestCases.LoadFlow (sim)0.01 (7 verified)0.012.010.190.381.090.120.100.322.96
Dynawo.Examples.Nordic.TestCases.TestCase 145.740.000.170.000.000.000.000.00146.61
Dynawo.Examples.Photovoltaics.WECC.PVCurrentSource (sim)0.04 (4 verified)0.130.360.180.080.110.030.020.121.48
Dynawo.Examples.Photovoltaics.WECC.PVVoltageSource2 (sim)0.03 (4 verified)0.140.400.210.070.140.030.020.131.50
Dynawo.Examples.Photovoltaics.WECC.PVVoltageSource4 (sim)0.37 (4 verified)0.180.380.190.070.130.030.020.121.93
Dynawo.Examples.Photovoltaics.WECC.PVVoltageSourceNoPPC (sim)0.31 (4 verified)0.140.310.190.050.100.030.020.101.72
Dynawo.Examples.RVS.TestCases.LoadFlow (sim)0.01 (4/7 failed)7.891.770.180.350.940.110.080.2910.55
Dynawo.Examples.RVS.TestCases.TestA.TestAAlphaBetaLoadNoRestorative (sim)0.03 (2 verified)126.7028.570.172.745.570.931.1118.22156.31
Dynawo.Examples.RVS.TestCases.TestA.TestAAlphaBetaLoadRestorative (sim)0.07 (2 verified)142.2833.190.182.916.621.101.2821.28176.48
Dynawo.Examples.RVS.TestCases.TestA.TestAShuntNoRestorative (sim)0.07 (3/8 failed)39.0428.530.242.625.540.941.1318.2969.11
Dynawo.Examples.RVS.TestCases.TestB.TestBNoSvcLoadReset (sim)0.10 (7 verified)177.4132.640.172.536.381.061.3721.30211.15
Dynawo.Examples.RVS.TestCases.TestB.TestBNoSvcNoLoadReset (sim) 240.0831.650.182.575.890.981.2220.99272.72
Dynawo.Examples.RVS.TestCases.TestB.TestBSvcLoadReset (sim)0.05 (7 verified)101.1528.820.192.655.670.971.1818.34131.07
Dynawo.Examples.RVS.TestCases.TestB.TestBSvcNoLoadReset (sim)0.05 (7 verified)138.1928.710.182.615.580.971.1718.38167.92
Dynawo.Examples.SMIB.SMIBStepEfdPm (sim)0.01 (3 verified)0.010.160.180.030.050.010.010.051.06
Dynawo.Examples.SMIB.SMIBStepPm (sim)0.01 (3 verified)0.090.200.170.030.070.020.010.071.31
Dynawo.Examples.SMIB.Standard.GovCt2St4b (sim)0.01 (5 verified)0.040.340.180.060.120.030.020.121.32
Dynawo.Examples.SMIB.Standard.GovHydro4St4b (sim)0.01 (2/4 failed)0.050.250.170.050.080.020.010.091.23
Dynawo.Examples.SMIB.Standard.GovSteam1St4b2 (sim)0.01 (5 verified)0.060.260.210.050.080.020.020.091.22
Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b1 (sim)0.01 (5 verified)0.040.310.180.060.090.020.020.121.27
Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b3 (sim)0.01 (5 verified)0.220.380.190.070.140.030.020.121.58
Dynawo.Examples.SMIB.Standard.GovSteamEuSt4b (sim)0.03 (5 verified)0.050.330.190.050.120.020.020.121.35
Dynawo.Examples.SVarC.SVarCFaultImp (sim)0.00 (3 verified)0.010.090.190.020.030.010.010.030.98
Dynawo.Examples.SVarC.SVarCLoadVarQ (sim)0.01 (3 verified)0.010.100.190.020.030.010.010.031.05
Dynawo.Examples.SVarC.SVarCLoadVarQLarge (sim)0.01 (3 verified)0.010.100.190.020.030.010.010.030.97
Dynawo.Examples.SVarC.SVarCModeChange (sim)0.01 (3 verified)0.010.100.200.020.030.010.010.031.04
Dynawo.Examples.SVarC.SVarCStepURef (sim)0.00 (2 verified)0.000.090.220.020.020.010.010.031.06
Dynawo.Examples.SystemFrequencyResponse.ReducedOrderSFR (sim)0.01 (2 verified)0.010.040.190.010.010.010.010.010.93
Dynawo.Examples.SystemFrequencyResponse.SimplifiedSFR (sim)0.01 (2 verified)0.010.050.270.010.010.010.010.020.96
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2015 (sim) 0.141.040.200.260.400.070.060.252.23
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2020 (sim)0.05 (3/4 failed)0.401.110.180.280.410.070.070.282.70
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2020FOCB (sim)0.21 (2/4 failed)1.471.080.230.260.400.080.060.284.08
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2020UDip (sim) 136.981.130.180.260.420.080.080.29139.69
Dynawo.Examples.Wind.IEC.Neplan.WPP4BCurrentSource2020 (sim)0.04 (3/4 failed)0.351.110.190.280.410.070.060.282.61
Dynawo.Examples.Wind.IEC.Neplan.WPP4BCurrentSource2020FOCB (sim)0.04 (3/4 failed)0.201.080.180.250.400.070.060.292.34
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015 (sim)0.03 (3 verified)0.180.640.180.140.260.040.040.171.77
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015FOCB (sim)0.03 (3 verified)0.130.670.180.150.270.040.030.171.77
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2020 (sim)0.04 (4 verified)0.220.680.180.150.250.040.040.201.90
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2020FOCB 0.000.080.170.080.000.000.000.001.11
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2015 (sim)0.05 (3 verified)0.190.670.180.150.260.050.040.171.97
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2015FOCB (sim) 0.110.640.180.150.250.040.040.161.73
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2020 (sim)0.05 (4 verified)0.200.720.180.150.250.040.040.241.97
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2020FOCB (sim)0.03 (4 verified)0.130.740.180.160.250.040.040.241.86
Dynawo.Examples.Wind.WECC.WT3CurrentSource1 (sim)0.37 (4 verified)0.120.310.190.070.100.020.020.111.84
Dynawo.Examples.Wind.WECC.WT3CurrentSource2 (sim)0.36 (4 verified)0.120.350.190.070.100.030.020.131.86
Dynawo.Examples.Wind.WECC.WT4ACurrentSource (sim)0.30 (4 verified)0.110.280.190.060.080.020.020.101.70
Dynawo.Examples.Wind.WECC.WT4BCurrentSource (sim)0.35 (4 verified)0.100.260.190.060.080.020.010.091.71
Dynawo.Examples.Wind.WECC.WTG3CurrentSource1 (sim)0.48 (4 verified)0.150.490.180.120.160.040.030.142.18
Dynawo.Examples.Wind.WECC.WTG3CurrentSource2 (sim)0.57 (4 verified)0.170.500.230.120.170.040.030.152.32
Dynawo.Examples.Wind.WECC.WTG4ACurrentSource (sim)4.85 (4 verified)1.310.430.180.090.140.050.030.137.73
Dynawo.Examples.Wind.WECC.WTG4BCurrentSource (sim)0.39 (4 verified)0.140.410.180.090.140.040.030.131.98
Dynawo.Examples.Wind.WECC.WTG4BCurrentSourceExternalPCS (sim)4.29 (1/4 failed)1.680.410.180.090.140.030.020.1311.78