Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticAerocondenser.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "[:1:22-1:33:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 13743895347 into a real Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.05296/0.05296, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] Using package ThermoSysPro with version 4.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: simulate(ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticAerocondenser,startTime=0,stopTime=1000,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticAerocondenser",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") simulate(ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticAerocondenser,startTime=0,stopTime=1000,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticAerocondenser",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") [Timeout 900] "Notification: Performance of FrontEnd - loaded program: time 7.91e-07/7.91e-07, allocations: 0 / 0, free: 0 / 0 Notification: Performance of FrontEnd - Absyn->SCode: time 1.661e-05/1.74e-05, allocations: 0 / 0, free: 0 / 0 Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticAerocondenser): time 0.1381/0.1381, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInst.instExpressions: time 0.2205/0.3586, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInst.updateImplicitVariability: time 0.0004138/0.359, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SourcePQ.mo:44:3-45:78:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/Sink.mo:29:3-30:80:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SourceP.mo:39:3-40:78:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:22:3-23:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:24:3-25:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:22:3-23:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:24:3-25:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/Sink.mo:29:3-30:80:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:22:3-23:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:24:3-25:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticAerocondenser.mo:56:3-57:79:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticAerocondenser.mo:58:3-59:81:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticAerocondenser.mo:60:3-61:81:writable] Warning: Connector Cair1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticAerocondenser.mo:62:3-63:80:writable] Warning: Connector Cair2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticAerocondenser.mo:64:3-65:141:writable] Warning: Connector Cw is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0005998/0.3596, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFTyping.typeBindings: time 0.001006/0.3606, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFTyping.typeClassSections: time 0.03066/0.3913, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFFlatten.flatten: time 0.001476/0.3928, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFFlatten.resolveConnections: time 0.0006114/0.3934, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFEvalConstants.evaluate: time 0.001223/0.3946, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Error: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of FrontEnd: time 0.0004866/0.3951, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 900] [Calling sys.exit(0), Time elapsed: 0.8465723237022758]