Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleDynamicCondenser.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "[:1:22-1:33:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 13743895347 into a real Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.05168/0.05168, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] Using package ThermoSysPro with version 4.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: simulate(ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleDynamicCondenser,startTime=0,stopTime=1000,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleDynamicCondenser",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") simulate(ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleDynamicCondenser,startTime=0,stopTime=1000,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleDynamicCondenser",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") [Timeout 900] "Notification: Performance of FrontEnd - loaded program: time 9.52e-07/9.52e-07, allocations: 0 / 0, free: 0 / 0 Notification: Performance of FrontEnd - Absyn->SCode: time 1.063e-05/1.158e-05, allocations: 0 / 0, free: 0 / 0 Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleDynamicCondenser): time 0.1386/0.1386, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInst.instExpressions: time 0.2278/0.3664, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInst.updateImplicitVariability: time 0.0005373/0.367, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SinkP.mo:32:3-33:80:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:22:3-23:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:24:3-25:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SourceP.mo:39:3-40:78:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SinkQ.mo:31:3-32:80:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SourceQ.mo:39:3-40:78:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:22:3-23:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:24:3-25:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:22:3-23:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:24:3-25:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:22:3-23:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:24:3-25:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:90:3-91:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:92:3-93:79:writable] Warning: Connector Cl is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:98:3-99:81:writable] Warning: Connector Cee is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:100:3-101:79:writable] Warning: Connector Cse is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0006624/0.3676, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFTyping.typeBindings: time 0.001204/0.3688, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFTyping.typeClassSections: time 0.03266/0.4015, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFFlatten.flatten: time 0.001336/0.4028, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFFlatten.resolveConnections: time 0.000629/0.4035, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFEvalConstants.evaluate: time 0.001395/0.4049, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:470:9-470:27:writable] Error: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of FrontEnd: time 0.0004761/0.4053, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 900] [Calling sys.exit(0), Time elapsed: 0.8457103087566793]