Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.TestTransformerFixedRatio.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(PowerGrids.Electrical.Test.TestTransformerFixedRatio,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.TestTransformerFixedRatio") translateModel(PowerGrids.Electrical.Test.TestTransformerFixedRatio,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.TestTransformerFixedRatio") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001397/0.001397, allocations: 170.2 kB / 16.11 MB, free: 5.582 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.653/1.653, allocations: 205.4 MB / 222.3 MB, free: 13.61 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007425/0.0007426, allocations: 94.28 kB / 270.6 MB, free: 13.12 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo): time 0.05485/0.05485, allocations: 14.2 MB / 333.1 MB, free: 8.57 MB / 234.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0006237/0.0006239, allocations: 16.33 kB / 394.9 MB, free: 50.82 MB / 282.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1106/0.1113, allocations: 51.12 MB / 446 MB, free: 6.242 MB / 282.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.11/0.2213, allocations: 84.89 MB / 0.5184 GB, free: 1.23 MB / 362.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002336/0.2216, allocations: 79.95 kB / 0.5185 GB, free: 1.152 MB / 362.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBus$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.TestTransformerFixedRatio Notification: Performance of FrontEnd: time 0.2032/0.4248, allocations: 5.591 MB / 0.524 GB, free: 83.24 MB / 362.7 MB