Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneOneYear.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneOneYear,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneOneYear") translateModel(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneOneYear,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneOneYear") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.673/1.673, allocations: 288.4 MB / 304.3 MB, free: 8.035 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001074/0.001074, allocations: 186.1 kB / 372.9 MB, free: 10.14 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.707/1.707, allocations: 205.4 MB / 0.6317 GB, free: 9.812 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009248/0.0009251, allocations: 92.94 kB / 0.745 GB, free: 5.73 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004/0.0004001, allocations: 11.38 kB / 0.8681 GB, free: 141.9 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2508/0.2512, allocations: 115.3 MB / 0.9807 GB, free: 27.4 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.896/5.147, allocations: 2.112 GB / 3.093 GB, free: 196.7 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003031/5.148, allocations: 101.1 kB / 3.093 GB, free: 196.6 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneOneYear Notification: Performance of FrontEnd: time 0.2863/5.434, allocations: 156.7 MB / 3.246 GB, free: 37.42 MB / 0.948 GB