Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain") translateModel(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.664/1.664, allocations: 288.4 MB / 304.3 MB, free: 8.195 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001033/0.001033, allocations: 180.4 kB / 372.9 MB, free: 10.16 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.661/1.661, allocations: 205.4 MB / 0.6317 GB, free: 9.879 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009124/0.0009123, allocations: 104.1 kB / 0.7451 GB, free: 5.781 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004242/0.0004243, allocations: 15.69 kB / 0.8681 GB, free: 141.8 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.243/0.2435, allocations: 115.3 MB / 0.9807 GB, free: 27.42 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.98/5.224, allocations: 2.112 GB / 3.093 GB, free: 196.5 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002513/5.224, allocations: 103.9 kB / 3.093 GB, free: 196.4 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain Notification: Performance of FrontEnd: time 1.221/6.445, allocations: 425.6 MB / 3.509 GB, free: 142.8 MB / 0.948 GB