Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPControl.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: translateModel(Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPControl,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPControl") translateModel(Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPControl,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPControl") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.6/1.6, allocations: 288.4 MB / 304.3 MB, free: 7.996 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00104/0.00104, allocations: 182.5 kB / 372.9 MB, free: 10.16 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.437/1.437, allocations: 205.4 MB / 0.6317 GB, free: 9.93 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007855/0.0007855, allocations: 89.23 kB / 0.745 GB, free: 5.832 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0003685/0.0003686, allocations: 11.56 kB / 0.8681 GB, free: 141.8 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1949/0.1953, allocations: 115.3 MB / 0.9807 GB, free: 27.42 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.007/5.202, allocations: 2.395 GB / 3.375 GB, free: 277.6 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002592/5.203, allocations: 99.95 kB / 3.376 GB, free: 277.5 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Utilities/Psychrometrics/X_pTphi.mo:37:3-40:14:writable] Error: Illegal subscript i_w for dimensions 2 in component X[i_w]. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Utilities/Psychrometrics/X_pTphi.mo:37:3-40:14:writable] Error: Variable X[i_w] not found in scope Buildings.Utilities.Psychrometrics.X_pTphi$x_pTphi. Error: Error occurred while flattening model Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPControl Notification: Performance of FrontEnd: time 0.266/5.469, allocations: 150.5 MB / 3.523 GB, free: 124.6 MB / 0.948 GB