Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: translateModel(Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel") translateModel(Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.628/1.628, allocations: 288.4 MB / 304.3 MB, free: 8.098 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001559/0.001559, allocations: 172.6 kB / 373 MB, free: 10.16 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.509/1.509, allocations: 205.4 MB / 0.6317 GB, free: 9.883 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0006981/0.0006979, allocations: 106.2 kB / 0.745 GB, free: 5.801 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.000391/0.0003911, allocations: 17.03 kB / 0.8681 GB, free: 141.8 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2074/0.2078, allocations: 115.3 MB / 0.9807 GB, free: 27.41 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.273/5.481, allocations: 2.408 GB / 3.388 GB, free: 261.9 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002448/5.481, allocations: 104 kB / 3.389 GB, free: 261.8 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-12:61:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Fluid/HeatExchangers/CoolingTowers/Examples/BaseClasses/PartialStaticTwoPortCoolingTower.mo:11:3-20:71:writable] Error: component tow contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel Notification: Performance of FrontEnd: time 2.48/7.961, allocations: 0.7436 GB / 4.132 GB, free: 141.4 MB / 0.948 GB