Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: translateModel(Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented") translateModel(Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.59/1.59, allocations: 288.4 MB / 304.3 MB, free: 8.133 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009899/0.0009899, allocations: 178.2 kB / 372.9 MB, free: 10.15 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.441/1.441, allocations: 205.4 MB / 0.6317 GB, free: 9.902 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007955/0.0007955, allocations: 96 kB / 0.7451 GB, free: 5.809 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0003937/0.0003937, allocations: 11.75 kB / 0.8681 GB, free: 141.8 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2507/0.2511, allocations: 115.3 MB / 0.9807 GB, free: 27.4 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.167/5.418, allocations: 2.106 GB / 3.087 GB, free: 203.5 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000351/5.419, allocations: 99.94 kB / 3.087 GB, free: 203.4 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented Notification: Performance of FrontEnd: time 0.03024/5.449, allocations: 12.41 MB / 3.099 GB, free: 191 MB / 0.948 GB