Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_latest_Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL") translateModel(Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_latest_Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 1.705/1.705, allocations: 297.8 MB / 313.7 MB, free: 156 kB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001091/0.001092, allocations: 188.5 kB / 384.6 MB, free: 10.88 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.412/1.412, allocations: 223.2 MB / 0.6626 GB, free: 4.352 MB / 490.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008936/0.0008936, allocations: 95.77 kB / 0.7808 GB, free: 43.67 MB / 0.5417 GB Notification: Performance of FrontEnd - loaded program: time 0.000443/0.0004431, allocations: 16.53 kB / 0.9088 GB, free: 0.7148 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7137/0.7142, allocations: 120.3 MB / 1.026 GB, free: 56.78 MB / 0.698 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.038/1.752, allocations: 421.6 MB / 1.438 GB, free: 152.5 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002336/1.752, allocations: 94.47 kB / 1.438 GB, free: 152.5 MB / 0.8855 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/Fluid/HeatPumps/Examples/Carnot_y.mo:20:3-34:67:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Buildings.Fluid.HeatPumps.Carnot_y$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL Notification: Performance of FrontEnd: time 0.1348/1.887, allocations: 75.79 MB / 1.512 GB, free: 90.87 MB / 0.8855 GB