Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter") translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/package.mo): time 1.772/1.772, allocations: 293 MB / 309 MB, free: 4.801 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001026/0.001026, allocations: 171.5 kB / 378.7 MB, free: 1.02 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.528/1.528, allocations: 205.4 MB / 0.6383 GB, free: 9.07 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008367/0.0008369, allocations: 95.05 kB / 0.7527 GB, free: 62.43 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004388/0.0004387, allocations: 16 kB / 0.8768 GB, free: 10.55 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3001/0.3006, allocations: 116.4 MB / 0.9904 GB, free: 6.008 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.414/5.714, allocations: 2.133 GB / 3.124 GB, free: 79.85 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003219/5.715, allocations: 104.5 kB / 3.124 GB, free: 79.75 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/Utilities/Psychrometrics/X_pTphi.mo:37:3-40:14:writable] Error: Illegal subscript i_w for dimensions 2 in component X[i_w]. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/Utilities/Psychrometrics/X_pTphi.mo:37:3-40:14:writable] Error: Variable X[i_w] not found in scope Buildings.Utilities.Psychrometrics.X_pTphi. Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter Notification: Performance of FrontEnd: time 5.259/10.97, allocations: 1.519 GB / 4.643 GB, free: 20.12 MB / 0.9792 GB