Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/package.mo) Running command: translateModel(Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow") translateModel(Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/package.mo): time 1.651/1.651, allocations: 293 MB / 309 MB, free: 4.789 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009913/0.0009914, allocations: 180.5 kB / 378.7 MB, free: 1.027 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.5/1.5, allocations: 205.4 MB / 0.6383 GB, free: 8.219 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.000756/0.0007562, allocations: 94.11 kB / 0.7527 GB, free: 62.6 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004561/0.0004563, allocations: 12 kB / 0.8768 GB, free: 10.44 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2717/0.2722, allocations: 116.4 MB / 0.9904 GB, free: 5.891 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.141/6.413, allocations: 2.459 GB / 3.449 GB, free: 118.4 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000364/6.413, allocations: 101 kB / 3.449 GB, free: 118.3 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/Utilities/Psychrometrics/X_pTphi.mo:37:3-40:14:writable] Error: Illegal subscript i_w for dimensions 2 in component X[i_w]. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/Utilities/Psychrometrics/X_pTphi.mo:37:3-40:14:writable] Error: Variable X[i_w] not found in scope Buildings.Utilities.Psychrometrics.X_pTphi$x_pTphi. Error: Error occurred while flattening model Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow Notification: Performance of FrontEnd: time 0.09781/6.511, allocations: 51.45 MB / 3.5 GB, free: 66.3 MB / 0.948 GB