Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/package.mo) Running command: translateModel(Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb") translateModel(Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/package.mo): time 1.643/1.643, allocations: 293 MB / 309 MB, free: 4.828 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009826/0.0009826, allocations: 184.5 kB / 378.7 MB, free: 1.039 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.493/1.493, allocations: 205.4 MB / 0.6383 GB, free: 8.238 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.000872/0.0008718, allocations: 97.19 kB / 0.7527 GB, free: 62.85 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.000411/0.0004111, allocations: 19.98 kB / 0.8768 GB, free: 10.45 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2529/0.2534, allocations: 116.4 MB / 0.9904 GB, free: 5.91 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.887/6.14, allocations: 2.384 GB / 3.375 GB, free: 191.7 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002786/6.141, allocations: 108.5 kB / 3.375 GB, free: 191.6 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-12:61:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/Fluid/HeatExchangers/CoolingTowers/Examples/BaseClasses/PartialStaticTwoPortCoolingTower.mo:11:3-20:71:writable] Error: component tow contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb Notification: Performance of FrontEnd: time 1.135/7.275, allocations: 303.2 MB / 3.671 GB, free: 183 MB / 0.948 GB