Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/package.mo) Running command: translateModel(Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop") translateModel(Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/package.mo): time 1.681/1.681, allocations: 293 MB / 309 MB, free: 4.82 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0008923/0.0008924, allocations: 180.6 kB / 378.7 MB, free: 1 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.486/1.486, allocations: 205.4 MB / 0.6383 GB, free: 8.238 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.000757/0.0007569, allocations: 88.77 kB / 0.7527 GB, free: 62.78 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.000392/0.0003924, allocations: 12 kB / 0.8768 GB, free: 10.43 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2953/0.2957, allocations: 116.4 MB / 0.9904 GB, free: 5.875 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.699/1.994, allocations: 460.4 MB / 1.44 GB, free: 265 MB / 0.9323 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003588/1.995, allocations: 102 kB / 1.44 GB, free: 265 MB / 0.9323 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-12:61:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/Fluid/Boilers/Examples/BoilerPolynomialClosedLoop.mo:11:3-21:72:writable] Error: component boi contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop Notification: Performance of FrontEnd: time 0.4882/2.483, allocations: 229.9 MB / 1.665 GB, free: 69.5 MB / 0.9323 GB