Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/package.mo) Running command: translateModel(Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented") translateModel(Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/package.mo): time 1.759/1.759, allocations: 293 MB / 309 MB, free: 4.797 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001284/0.001284, allocations: 172.5 kB / 378.7 MB, free: 1.016 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.488/1.488, allocations: 205.4 MB / 0.6383 GB, free: 8.207 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007701/0.00077, allocations: 83.58 kB / 0.7527 GB, free: 62.55 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0003602/0.0003602, allocations: 15.98 kB / 0.8768 GB, free: 10.4 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2564/0.2568, allocations: 116.4 MB / 0.9904 GB, free: 5.855 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.532/5.789, allocations: 2.107 GB / 3.098 GB, free: 107 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003332/5.789, allocations: 104.6 kB / 3.098 GB, free: 106.9 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented Notification: Performance of FrontEnd: time 0.02846/5.817, allocations: 12.41 MB / 3.11 GB, free: 94.6 MB / 0.948 GB