Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Spring.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Spring,tolerance=1e-07,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Spring") translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Spring,tolerance=1e-07,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Spring") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.477/2.477, allocations: 287.5 MB / 303.2 MB, free: 8.207 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001401/0.001401, allocations: 183.2 kB / 371.8 MB, free: 10.82 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.072/2.072, allocations: 205.4 MB / 0.6305 GB, free: 10.57 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.00097/0.00097, allocations: 86.36 kB / 0.7438 GB, free: 6.574 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004899/0.00049, allocations: 11.25 kB / 0.8667 GB, free: 140.4 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2129/0.2134, allocations: 115.3 MB / 0.9793 GB, free: 28.2 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 8.458/8.672, allocations: 2.658 GB / 3.637 GB, free: 277.7 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004168/8.672, allocations: 113 kB / 3.637 GB, free: 277.7 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Spring Notification: Performance of FrontEnd: time 10.88/19.56, allocations: 2.179 GB / 5.816 GB, free: 69.46 MB / 1.042 GB