Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.MixingVolumes.Validation.MixingVolumeTraceSubstanceReverseFlow.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: translateModel(Buildings.Fluid.MixingVolumes.Validation.MixingVolumeTraceSubstanceReverseFlow,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Fluid.MixingVolumes.Validation.MixingVolumeTraceSubstanceReverseFlow") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.005933/0.005938, allocations: 232.8 kB / 15.82 MB, free: 6.293 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001746/0.001746, allocations: 173.2 kB / 16.7 MB, free: 5.449 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 4.057/4.057, allocations: 389.1 MB / 406.5 MB, free: 11.83 MB / 330.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 3.99/3.99, allocations: 472.3 MB / 0.9024 GB, free: 9.215 MB / 0.5886 GB Notification: Performance of FrontEnd - loaded program: time 0.0004901/0.0004904, allocations: 17.5 kB / 1.008 GB, free: 138.1 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1703/0.1708, allocations: 98.72 MB / 1.105 GB, free: 42.02 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.641/6.812, allocations: 2.179 GB / 3.284 GB, free: 26.46 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003381/6.812, allocations: 100.2 kB / 3.284 GB, free: 26.41 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/MixingVolumes/Validation/MixingVolumeTraceSubstanceReverseFlow.mo:10:9-10:18:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/PartialSource_Xi_C.mo:19:3-22:89:writable] Error: Array dimension mismatch, expression {0.003} has type Real[1], expected array dimensions [0]. Error: Error occurred while flattening model Buildings.Fluid.MixingVolumes.Validation.MixingVolumeTraceSubstanceReverseFlow Notification: Performance of FrontEnd: time 0.6607/7.473, allocations: 37.74 MB / 3.321 GB, free: 261.6 MB / 0.823 GB