Environment - simulationEnvironment: startTime=0 stopTime=100 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.1 Regular simulation: ./ThermofluidStream_ThermofluidStream.Undirected.HeatExchangers.Tests.ConductionElementTwoPhase -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00456274s reading init.xml | | | | | | 0.000395251s reading info.xml | | | | | | 0.000275808s [ 0.0%] pre-initialization | | | | | | 0.0290395s [ 0.4%] initialization | | | | | | 0.00106432s [ 0.0%] steps | | | | | | 0.0179979s [ 0.3%] solver (excl. callbacks) | | | | | | 0.0014342s [ 0.0%] creating output-file | | | | | | 0.0761973s [ 1.1%] event-handling | | | | | | 0.0134533s [ 0.2%] overhead | | | | | | 6.65914s [ 97.9%] simulation | | | | | | 6.79861s [100.0%] total | | | | | events | | | | | | 3 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 944 steps taken | | | | | | 1445 calls of functionODE | | | | | | 263 evaluations of jacobian | | | | | | 86 error test failures | | | | | | 1 convergence test failures | | | | | | 2.06224s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.