Environment - simulationEnvironment: startTime=0 stopTime=500 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.2 Regular simulation: ./ThermoPower_ThermoPower.Test.WaterComponents.TestExpansionTankIdeal -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00290534s reading init.xml | | | | | | 0.000295414s reading info.xml | | | | | | 0.000160531s [ 0.1%] pre-initialization | | | | | | 0.0367282s [ 13.1%] initialization | | | | | | 3.718e-05s [ 0.0%] steps | | | | | | 0.0383549s [ 13.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000560708s [ 0.2%] event-handling | | | | | | 0.0106349s [ 3.8%] overhead | | | | | | 0.194833s [ 69.3%] simulation | | | | | | 0.281309s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 168 steps taken | | | | | | 218 calls of functionODE | | | | | | 44 evaluations of jacobian | | | | | | 3 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00925312s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.