Environment - simulationEnvironment: startTime=0 stopTime=1500 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.6 Regular simulation: ./ScalableTestSuite_ScalableTestSuite.Thermal.HeatConduction.ScaledExperiments.OneDHeatTransferTI_Modelica_N_320 -abortSlowSimulation -alarm=300 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0460133s reading init.xml | | | | | | 0.00334512s reading info.xml | | | | | | 0.00122898s [ 1.3%] pre-initialization | | | | | | 0.000643276s [ 0.7%] initialization | | | | | | 1.3435e-05s [ 0.0%] steps | | | | | | 0.0111226s [ 11.9%] solver (excl. callbacks) | | | | | | 0.0129888s [ 13.9%] creating output-file | | | | | | 0.000133066s [ 0.1%] event-handling | | | | | | 0.000550774s [ 0.6%] overhead | | | | | | 0.0670132s [ 71.5%] simulation | | | | | | 0.0936942s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 214 steps taken | | | | | | 250 calls of functionODE | | | | | | 27 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00156197s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.