Environment - simulationEnvironment: startTime=0 stopTime=1500 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.6 Regular simulation: ./ScalableTestSuite_ScalableTestSuite.Thermal.HeatConduction.ScaledExperiments.OneDHeatTransferTI_FD_N_10 -abortSlowSimulation -alarm=300 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.000531878s reading init.xml | | | | | | 5.1186e-05s reading info.xml | | | | | | 0.000373361s [ 8.7%] pre-initialization | | | | | | 0.000121538s [ 2.8%] initialization | | | | | | 4.21e-07s [ 0.0%] steps | | | | | | 0.00110635s [ 25.8%] solver (excl. callbacks) | | | | | | 0.000704402s [ 16.4%] creating output-file | | | | | | 6.37922e-21s [ 0.0%] event-handling | | | | | | 0.000249365s [ 5.8%] overhead | | | | | | 0.00165023s [ 38.5%] simulation | | | | | | 0.00432468s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 125 steps taken | | | | | | 144 calls of functionODE | | | | | | 19 evaluations of jacobian | | | | | | 1 error test failures | | | | | | 0 convergence test failures | | | | | | 3.97914e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.