Environment - simulationEnvironment: startTime=0 stopTime=120 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.048 Regular simulation: ./IndustrialControlSystems_IndustrialControlSystems.Controllers.Examples.TestP_tracking -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00185984s reading init.xml | | | | | | 0.000187462s reading info.xml | | | | | | 0.000119214s [ 1.6%] pre-initialization | | | | | | 0.000101981s [ 1.4%] initialization | | | | | | 8.61e-07s [ 0.0%] steps | | | | | | 0.00181364s [ 24.5%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 2.8049e-05s [ 0.4%] event-handling | | | | | | 0.0010574s [ 14.3%] overhead | | | | | | 0.00428768s [ 57.9%] simulation | | | | | | 0.00740883s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 352 steps taken | | | | | | 481 calls of functionODE | | | | | | 126 evaluations of jacobian | | | | | | 19 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000194844s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.