Environment - simulationEnvironment: startTime=0 stopTime=15 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.006 Regular simulation: ./ClaRa_dev_ClaRa.Components.TurboMachines.Compressors.Check.Test_CompressorGas_L1_affinity -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0173424s reading init.xml | | | | | | 0.00150328s reading info.xml | | | | | | 0.0118286s [ 10.5%] pre-initialization | | | | | | 0.037914s [ 33.6%] initialization | | | | | | 7.724e-06s [ 0.0%] steps | | | | | | 0.0396469s [ 35.2%] solver (excl. callbacks) | | | | | | 0.00829793s [ 7.4%] creating output-file | | | | | | 6.5646e-05s [ 0.1%] event-handling | | | | | | 0.00514621s [ 4.6%] overhead | | | | | | 0.0098038s [ 8.7%] simulation | | | | | | 0.112711s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 141 steps taken | | | | | | 177 calls of functionODE | | | | | | 69 evaluations of jacobian | | | | | | 1 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000248655s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.