Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=500 stepSize=0.002 Regular simulation: ./ClaRa_ClaRa.Components.Electrical.Check.TestAsynchronousMotorWithPump -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0148956s reading init.xml | | | | | | 0.00232755s reading info.xml | | | | | | 0.0135581s [ 15.8%] pre-initialization | | | | | | 0.0504184s [ 58.8%] initialization | | | | | | 1.088e-05s [ 0.0%] steps | | | | | | 0.054514s [ 63.5%] solver (excl. callbacks) | | | | | | 0.00238846s [ 2.8%] creating output-file | | | | | | 0.000174921s [ 0.2%] event-handling | | | | | | 0.00143698s [ 1.7%] overhead | | | | | | -0.0367009s [-42.8%] simulation | | | | | | 0.0858009s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 674 steps taken | | | | | | 1056 calls of functionODE | | | | | | 192 evaluations of jacobian | | | | | | 70 error test failures | | | | | | 1 convergence test failures | | | | | | 0.00245657s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.