startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned -abortSlowSimulation -alarm=480 -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.5.0-e579c2aa82 (No OpenGL), YMD=2021.12.10 00:14 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-ATTIC-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-CORE_ZN-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_1-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_2-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_3-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_4-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.flo.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0397616s reading init.xml | | | | | | 0.00323368s reading info.xml | | | | | | 0.000316223s [ 0.0%] pre-initialization | | | | | | 1.073s [ 49.7%] initialization | | | | | | 0.000414016s [ 0.0%] steps | | | | | | 1.38428s [ 64.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.486652s [ 22.6%] event-handling | | | | | | 0.0343172s [ 1.6%] overhead | | | | | | -0.821986s [-38.1%] simulation | | | | | | 2.15699s [100.0%] total | | | | | events | | | | | | 287 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 9838 steps taken | | | | | | 14186 calls of functionODE | | | | | | 3785 evaluations of jacobian | | | | | | 344 error test failures | | | | | | 6 convergence test failures | | | | | | 0.364615s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 1.54sec EnergyPlus Completed Successfully.