Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_latest_Buildings.Fluid.Chillers.Examples.AbsorptionIndirectSteamVaryingLoad -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in AbsorptionIndirectSteamVaryingLoad.pum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pum.per.haveWMot_nominal or not (pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in AbsorptionIndirectSteamVaryingLoad.pum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STDOUT | info | ##IDA## -4 error occurred at time = 0.00356829428555897 LOG_STDOUT | info | model terminate | Integrator failed. | Simulation terminated at time 0.00356829 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0123189s reading init.xml | | | | | | 0.000958518s reading info.xml | | | | | | 0.00067689s [ 23.5%] pre-initialization | | | | | | 0.000615575s [ 21.4%] initialization | | | | | | 0.00149474s [ 51.9%] steps | | | | | | 0.00109376s [ 38.0%] solver (excl. callbacks) | | | | | | 0.000337944s [ 11.7%] creating output-file | | | | | | 2.825e-06s [ 0.1%] event-handling | | | | | | 1.065e-05s [ 0.4%] overhead | | | | | | -0.00135506s [-47.1%] simulation | | | | | | 0.00287733s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 156 steps taken | | | | | | 352 calls of functionODE | | | | | | 95 evaluations of jacobian | | | | | | 31 error test failures | | | | | | 21 convergence test failures | | | | | | 0.000617136s time of jacobian evaluation