Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.Validation.Sandbox.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.Borefields.Validation.Sandbox,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.Validation.Sandbox") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.004284/0.004283, allocations: 234.6 kB / 15.8 MB, free: 6.285 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001192/0.001191, allocations: 179.2 kB / 16.69 MB, free: 5.449 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 3.836/3.836, allocations: 389.1 MB / 406.5 MB, free: 11.84 MB / 330.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 3.887/3.887, allocations: 472.3 MB / 0.9024 GB, free: 18.77 MB / 442.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0005246/0.000525, allocations: 12 kB / 1.008 GB, free: 13.44 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2283/0.2289, allocations: 98.72 MB / 1.105 GB, free: 10.76 MB / 0.573 GB Notification: Performance of NFInst.instantiate(Buildings.Fluid.Geothermal.Borefields.Validation.Sandbox): time 0.7667/0.9957, allocations: 113.1 MB / 1.215 GB, free: 9.289 MB / 0.6042 GB Notification: Performance of NFInst.instExpressions: time 0.07098/1.067, allocations: 33.97 MB / 1.248 GB, free: 1.355 MB / 0.6198 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.00646/1.073, allocations: 113.5 kB / 1.248 GB, free: 1.309 MB / 0.6198 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Geothermal/Borefields/Validation/Sandbox.mo:20:40-21:14:writable] Error: Component borFieDat of variability parameter has binding 'borFieDat' of higher variability continuous. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFCeval.mo:1102:9-1102:67:writable] Error: Internal error NFCeval.evalBinaryPow failed to evaluate ‘borHol.borFieDat.conDat.hBor ^ 2.0‘