Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=216 tolerance=1e-06 numberOfIntervals=27000 stepSize=0.008 Regular simulation: ./TransiEnt_TransiEnt.Storage.Gas.Check.TestGasStorage_constXi_L2 -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:158:3-162:32:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pipe_32.rho_nom[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= pipe_32.rho_nom[1], has value: -7.45239e+302" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:158:3-162:32:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pipe_54.rho_nom[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= pipe_54.rho_nom[1], has value: -7.45239e+302" Limited backtrace at point of segmentation fault /lib/x86_64-linux-gnu/libc.so.6(+0x42520)[0x7f148dd27520] ./TransiEnt_TransiEnt.Storage.Gas.Check.TestGasStorage_constXi_L2(TransiEnt_TransiEnt_Storage_Gas_Check_TestGasStorage_constXi_L2_eqFunction_359+0x2c)[0x55800917c8ae] ./TransiEnt_TransiEnt.Storage.Gas.Check.TestGasStorage_constXi_L2(TransiEnt_TransiEnt_Storage_Gas_Check_TestGasStorage_constXi_L2_functionInitialEquations_lambda0+0x1090)[0x55800911aefb] /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libSimulationRuntimeC.so(+0x260a83)[0x7f148ecd5a83] /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libSimulationRuntimeC.so(initialization+0x401)[0x7f148ecd5041] /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libSimulationRuntimeC.so(initializeModel+0xff)[0x7f148ec6106f] /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libSimulationRuntimeC.so(solver_main+0x1d5)[0x7f148ec62315] /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libSimulationRuntimeC.so(+0x2db502)[0x7f148ed50502] /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libSimulationRuntimeC.so(startNonInteractiveSimulation+0xdc1)[0x7f148ed4f5c1] /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libSimulationRuntimeC.so(_main_SimulationRuntime+0x5d)[0x7f148ed5324d] ./TransiEnt_TransiEnt.Storage.Gas.Check.TestGasStorage_constXi_L2(main+0x1d9)[0x5580090fda20] /lib/x86_64-linux-gnu/libc.so.6(+0x29d90)[0x7f148dd0ed90] /lib/x86_64-linux-gnu/libc.so.6(__libc_start_main+0x80)[0x7f148dd0ee40] ./TransiEnt_TransiEnt.Storage.Gas.Check.TestGasStorage_constXi_L2(_start+0x25)[0x5580090eecf5]