Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo): time 2.326/2.326, allocations: 395.9 MB / 417.1 MB, free: 13.48 MB / 318.1 MB " [Timeout remaining time 177] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo): time 0.0007648/0.0007648, allocations: 31.88 kB / 0.5046 GB, free: 11.32 MB / 414.1 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestReheater, which is expected to be stored in file TestReheater.mo, but seems to be named testReheater.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/testReheater.mo:2:1-117:17:writable] Warning: Expected the package to have name testReheater, but got TestReheater. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/package.mo:2:1-23:10:writable] Warning: PhysicalMills was referenced in the package.order file, but was not found in package.mo, PhysicalMills/package.mo or PhysicalMills.mo. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: Expected the package to have name physicalMills, but got PhysicalMills. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4_advancedInit, which is expected to be stored in file Mill_L4_advancedInit.mo, but seems to be named mill_L4_advancedInit.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4, which is expected to be stored in file Mill_L4.mo, but seems to be named mill_L4.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have name mill_L4_advancedInit, but got Mill_L4_advancedInit. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have name mill_L4, but got Mill_L4. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_2, which is expected to be stored in file TestMillBox_2.mo, but seems to be named testMillBox_2.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1_measurementInput, which is expected to be stored in file TestMillBox_1_measurementInput.mo, but seems to be named testMillBox_1_measurementInput.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1, which is expected to be stored in file TestMillBox_1.mo, but seems to be named testMillBox_1.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have name testMillBox_2, but got TestMillBox_2. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have name testMillBox_1_measurementInput, but got TestMillBox_1_measurementInput. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have name testMillBox_1, but got TestMillBox_1. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/package.mo:2:1-29:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FlowClassifier.mo:2:1-346:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/CentrifugalClassifier.mo:2:1-380:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/GrinderRingRoller.mo:2:1-294:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FuelJoin_distributed.mo:2:1-133:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Dryer.mo:2:1-301:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/package.mo:2:1-20:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/package.mo:2:1-20:13:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_complex.mo:2:1-71:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_constant.mo:2:1-49:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_base.mo:2:1-52:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Kersting.mo:2:1-80:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Steinmetz.mo:2:1-104:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_constant.mo:2:1-45:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_base.mo:2:1-50:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/package.mo:2:1-20:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Austin.mo:2:1-109:20:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Steinmetz.mo:2:1-106:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_constant.mo:2:1-45:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_base.mo:2:1-51:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/package.mo:2:1-20:11:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_ideal.mo:2:1-58:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_base.mo:2:1-44:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/package.mo:2:1-20:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow.mo:2:1-111:21:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal.mo:2:1-153:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal_base.mo:2:1-45:33:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow_base.mo:2:1-45:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/package.mo:2:1-20:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Dryer.mo:2:1-57:15:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_FlowClassifier.mo:2:1-67:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_CentrifugalClassifier.mo:2:1-69:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Grinder.mo:2:1-61:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_21classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/GeometricProgression.mo:2:1-56:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_generic.mo:2:1-43:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_05classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_11classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_base.mo:2:1-61:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestFuelJoin, which is expected to be stored in file TestFuelJoin.mo, but seems to be named testFuelJoin.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestAerosolVolume, which is expected to be stored in file TestAerosolVolume.mo, but seems to be named testAerosolVolume.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestDryer, which is expected to be stored in file TestDryer.mo, but seems to be named testDryer.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestGrinder, which is expected to be stored in file TestGrinder.mo, but seems to be named testGrinder.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have name testFuelJoin, but got TestFuelJoin. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have name testAerosolVolume, but got TestAerosolVolume. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have name testDryer, but got TestDryer. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have name testGrinder, but got TestGrinder. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo): time 1.359/1.359, allocations: 128.7 MB / 0.7276 GB, free: 16.91 MB / 0.4982 GB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/package.mo): time 0.114/0.114, allocations: 23.17 MB / 0.8745 GB, free: 7.855 MB / 0.6232 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo): time 0.01162/0.01162, allocations: 0.8866 MB / 1.006 GB, free: 194.4 MB / 0.7325 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo): time 0.289/0.289, allocations: 45.28 MB / 1.181 GB, free: 45.21 MB / 0.7325 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo): time 0.1045/0.1045, allocations: 13.78 MB / 1.334 GB, free: 219.3 MB / 0.795 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001308/0.001308, allocations: 116.8 kB / 1.477 GB, free: 82.51 MB / 0.795 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001592/0.001592, allocations: 199.2 kB / 1.62 GB, free: 242.6 MB / 0.8419 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.983/1.983, allocations: 225.6 MB / 1.983 GB, free: 91.66 MB / 0.8888 GB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo): time 0.0008178/0.0008178, allocations: 31.94 kB / 2.177 GB, free: 3.25 MB / 0.9357 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo): time 0.00085/0.00085, allocations: 31.61 kB / 2.371 GB, free: 271 MB / 1.108 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo): time 1.2/1.2, allocations: 223.5 MB / 2.783 GB, free: 14.23 MB / 1.201 GB " [Timeout remaining time 177] Using package TransiEnt with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo) Using package DataFiles with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo) Using package Design with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo) Using package Modelica_LinearSystems2 with version 2.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo) Using package ModelicaReference with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo) Using package TILMedia with version 1.8.2 ClaRa (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/package.mo) Using package ClaRa with version 1.8.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo) Using package DymolaCommands with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo) Using package Buildings with version 9.1.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo) Running command: translateModel(TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1") translateModel(TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1") [Timeout 660] "Warning: Requested package TILMedia of version 1.8.1 ClaRa, but this package was already loaded with version 1.8.2 ClaRa. OpenModelica cannot reason about compatibility between the two packages since they are not semantic versions. Warning: Requested package TILMedia of version 1.8.0 ClaRa, but this package was already loaded with version 1.8.2 ClaRa. OpenModelica cannot reason about compatibility between the two packages since they are not semantic versions. Warning: TransiEnt requested package ClaRa of version 1.8.0. ClaRa 1.8.1 is used instead which states that it is only compatible with a conversion script. Use convertPackageToLibrary(TransiEnt, ClaRa, \"1.8.1\") to run the conversion script or proceed with potential issues as a result. Notification: TransiEnt requested package Buildings of version 9.0.0. Buildings 9.1.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.01483/0.01483, allocations: 327.5 kB / 3.286 GB, free: 13.7 MB / 1.451 GB Notification: Performance of FrontEnd - Absyn->SCode: time 2.55/2.565, allocations: 243 MB / 3.524 GB, free: 44.45 MB / 1.514 GB Notification: Performance of NFInst.instantiate(TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1): time 0.02224/2.587, allocations: 21.99 MB / 3.545 GB, free: 28.71 MB / 1.514 GB Notification: Performance of NFInst.instExpressions: time 0.04051/2.628, allocations: 23.08 MB / 3.568 GB, free: 12.44 MB / 1.514 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.007918/2.636, allocations: 89.09 kB / 3.568 GB, free: 12.41 MB / 1.514 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/SimCenter.mo:69:5-70:35:writable] Warning: Connector cycleSumPort is not balanced: The number of potential variables (0) is not equal to the number of flow variables (4). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectHeatingPower.mo:68:3-68:143:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectGwpEmissionsHeat.mo:69:3-69:141:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:85:3-85:105:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:86:3-86:112:writable] Warning: Connector primBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:87:3-87:102:writable] Warning: Connector primBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:88:3-88:111:writable] Warning: Connector secBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:89:3-89:101:writable] Warning: Connector secBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:90:3-90:92:writable] Warning: Connector surroundingGridLoad is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:92:3-92:126:writable] Warning: Connector tielinePowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:93:3-93:130:writable] Warning: Connector tielineSetPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:95:3-95:95:writable] Warning: Connector kineticEnergyCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:98:3-98:99:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:100:3-100:107:writable] Warning: Connector gwpCollectorHeat is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:103:3-103:82:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:3-105:87:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). Notification: Performance of NFTyping.typeComponents: time 0.008878/2.645, allocations: 2.362 MB / 3.57 GB, free: 11.28 MB / 1.514 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/fullPathName.mo:2:1-78:17:writable] Warning: Pure function 'TransiEnt.Basics.Functions.fullPathName' contains a call to impure function 'Modelica.Utilities.Streams.print'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Heat/Gas2Heat/SmallGasBoiler/Base/PartialGasboiler.mo:57:3-60:187:writable] Warning: In relation simCenter.heatingCurve.T_supply_const == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/VLEFluidFunctions.mo:540:13-544:40:writable] Warning: Pure function 'TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidFunctions.specificIsobaricHeatCapacity_pTxi' contains a call to impure function 'TILMedia.Internals.VLEFluidFunctions.specificIsobaricHeatCapacity_pTxi'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/GasFunctions.mo:385:23-389:16:writable] Warning: Pure function 'TILMedia.GasFunctions.molarMass_n' contains a call to impure function 'TILMedia.Internals.GasFunctions.molarMass_n'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/GasProperties/getMolarMasses_idealGas.mo:2:1-79:28:writable] Warning: Pure function 'TransiEnt.Basics.Functions.GasProperties.getMolarMasses_idealGas' contains a call to impure function 'TILMedia.GasFunctions.molarMass_n'. Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil as Integer: 9. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others as Integer: 10. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Storage as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Storage) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Notification: Performance of NFTyping.typeBindings: time 0.01921/2.664, allocations: 2.911 MB / 3.573 GB, free: 9.59 MB / 1.514 GB Warning: Allowing usage of enumeration expression: Boiler.TypeOfResource as Integer: CAST(Integer, Boiler.TypeOfResource). This is non-standard Modelica, use Integer(Boiler.TypeOfResource) instead! Warning: Allowing usage of enumeration expression: Boiler.TypeOfEnergyCarrierHeat as Integer: CAST(Integer, Boiler.TypeOfEnergyCarrierHeat). This is non-standard Modelica, use Integer(Boiler.TypeOfEnergyCarrierHeat) instead! [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/GasProperties/comps2Elements_idealGas.mo:2:1-134:28:writable] Warning: Pure function 'TransiEnt.Basics.Functions.GasProperties.comps2Elements_idealGas' contains a call to impure function 'TransiEnt.Basics.Functions.GasProperties.getMolarMasses_idealGas'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/GasProperties/verboseXi.mo:2:1-93:14:writable] Warning: Pure function 'TransiEnt.Basics.Functions.GasProperties.verboseXi' contains a call to impure function 'Modelica.Utilities.Streams.print'. Notification: Performance of NFTyping.typeClassSections: time 0.01661/2.681, allocations: 3.268 MB / 3.576 GB, free: 7.789 MB / 1.514 GB Notification: Performance of NFFlatten.flatten: time 0.01822/2.699, allocations: 6.956 MB / 3.583 GB, free: 4.383 MB / 1.514 GB Notification: Performance of NFFlatten.resolveConnections: time 0.009304/2.708, allocations: 3.023 MB / 3.586 GB, free: 2.961 MB / 1.514 GB Notification: Performance of NFEvalConstants.evaluate: time 0.01059/2.719, allocations: 3.436 MB / 3.589 GB, free: 1.531 MB / 1.514 GB Notification: Performance of NFSimplifyModel.simplify: time 0.01004/2.729, allocations: 3.741 MB / 3.593 GB, free: 15.81 MB / 1.53 GB Notification: Performance of NFPackage.collectConstants: time 0.005042/2.734, allocations: 0.7163 MB / 3.594 GB, free: 15.81 MB / 1.53 GB Notification: Performance of NFFlatten.collectFunctions: time 0.06465/2.798, allocations: 9.591 MB / 3.603 GB, free: 13.13 MB / 1.53 GB Notification: Performance of NFScalarize.scalarize: time 0.008779/2.807, allocations: 3.117 MB / 3.606 GB, free: 11.71 MB / 1.53 GB Notification: Performance of NFVerifyModel.verify: time 0.01756/2.825, allocations: 4.254 MB / 3.61 GB, free: 8.785 MB / 1.53 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:79:53-79:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:83:53-83:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/EconomicStatistics.mo:42:70-42:85:writable] Error: Variable True not found in scope EconomicStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:71-105:86:writable] Error: Variable True not found in scope ModelStatistics. Notification: Performance of NFConvertDAE.convert: time 0.08902/2.914, allocations: 34.74 MB / 3.644 GB, free: 11.79 MB / 1.545 GB Notification: Performance of FrontEnd - DAE generated: time 8.385e-06/2.914, allocations: 4 kB / 3.644 GB, free: 11.78 MB / 1.545 GB Notification: Performance of FrontEnd: time 2.305e-06/2.914, allocations: 0 / 3.644 GB, free: 11.78 MB / 1.545 GB Notification: Performance of Transformations before backend: time 0.0007682/2.914, allocations: 1.094 kB / 3.644 GB, free: 11.78 MB / 1.545 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 1066 * Number of variables: 1066 Notification: Performance of Generate backend data structure: time 0.04622/2.961, allocations: 10.16 MB / 3.654 GB, free: 4.461 MB / 1.545 GB Notification: Performance of prepare preOptimizeDAE: time 6.131e-05/2.961, allocations: 12.03 kB / 3.654 GB, free: 4.449 MB / 1.545 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.006622/2.967, allocations: 1.026 MB / 3.655 GB, free: 3.418 MB / 1.545 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.03252/3, allocations: 12.43 MB / 3.667 GB, free: 6.898 MB / 1.561 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0006439/3.001, allocations: 335.8 kB / 3.667 GB, free: 6.551 MB / 1.561 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.002241/3.003, allocations: 324 kB / 3.668 GB, free: 6.234 MB / 1.561 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.02165/3.024, allocations: 6.842 MB / 3.674 GB, free: 14.3 MB / 1.577 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.0003923/3.025, allocations: 27.69 kB / 3.674 GB, free: 14.28 MB / 1.577 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.002586/3.027, allocations: 180 kB / 3.675 GB, free: 14.1 MB / 1.577 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.000371/3.028, allocations: 167.2 kB / 3.675 GB, free: 13.94 MB / 1.577 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.01451/3.042, allocations: 5.223 MB / 3.68 GB, free: 8.707 MB / 1.577 GB Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.05586/3.098, allocations: 29.56 MB / 3.709 GB, free: 9.934 MB / 1.608 GB Notification: Performance of preOpt comSubExp (simulation): time 0.003782/3.102, allocations: 1.353 MB / 3.71 GB, free: 8.457 MB / 1.608 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.002043/3.104, allocations: 0.7741 MB / 3.711 GB, free: 7.641 MB / 1.608 GB Notification: Performance of preOpt evalFunc (simulation): time 0.01335/3.117, allocations: 4.96 MB / 3.716 GB, free: 2.449 MB / 1.608 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.00321/3.121, allocations: 1.337 MB / 3.717 GB, free: 0.9492 MB / 1.608 GB Notification: Performance of preOpt simplifyInStream (simulation): time 0.004143/3.125, allocations: 460.7 kB / 3.717 GB, free: 0.4961 MB / 1.608 GB Notification: Performance of pre-optimization done (n=312): time 2.143e-05/3.125, allocations: 0 / 3.717 GB, free: 0.4961 MB / 1.608 GB Notification: Performance of matching and sorting (n=312): time 0.01047/3.135, allocations: 3.755 MB / 3.721 GB, free: 12.71 MB / 1.624 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.001064/3.136, allocations: 1.586 MB / 3.723 GB, free: 10.75 MB / 1.624 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.0301/3.166, allocations: 8.496 MB / 3.731 GB, free: 2.316 MB / 1.624 GB Notification: Performance of collectPreVariables (initialization): time 0.0006073/3.167, allocations: 61.69 kB / 3.731 GB, free: 2.25 MB / 1.624 GB Notification: Performance of collectInitialEqns (initialization): time 0.007046/3.174, allocations: 3.992 MB / 3.735 GB, free: 14.23 MB / 1.639 GB Notification: Performance of collectInitialBindings (initialization): time 0.001978/3.176, allocations: 1.104 MB / 3.736 GB, free: 13.12 MB / 1.639 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.004791/3.181, allocations: 1.252 MB / 3.737 GB, free: 11.86 MB / 1.639 GB Notification: Performance of setup shared object (initialization): time 0.000163/3.181, allocations: 305.1 kB / 3.738 GB, free: 11.55 MB / 1.639 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.00384/3.185, allocations: 1.556 MB / 3.739 GB, free: 9.98 MB / 1.639 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.006995/3.192, allocations: 4.494 MB / 3.743 GB, free: 4.043 MB / 1.639 GB Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] (0.0 = $START.modelStatistics.heatingPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] (0.0 = $START.modelStatistics.heatingPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] (0.0 = $START.modelStatistics.heatingPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] (0.0 = $START.modelStatistics.heatingPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] (0.0 = $START.modelStatistics.heatingPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] (0.0 = $START.modelStatistics.heatingPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] (0.0 = $START.modelStatistics.electricPower.negPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] (0.0 = $START.modelStatistics.electricPower.negPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] (0.0 = $START.modelStatistics.electricPower.negPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] (0.0 = $START.modelStatistics.electricPower.negPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] (0.0 = $START.modelStatistics.electricPower.negPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] (0.0 = $START.modelStatistics.electricPower.negPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] (0.0 = $START.modelStatistics.electricPower.posPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] (0.0 = $START.modelStatistics.electricPower.posPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] (0.0 = $START.modelStatistics.electricPower.posPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] (0.0 = $START.modelStatistics.electricPower.posPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] (0.0 = $START.modelStatistics.electricPower.posPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] (0.0 = $START.modelStatistics.electricPower.posPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] (0.0 = $START.modelStatistics.electricPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] (0.0 = $START.modelStatistics.electricPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] (0.0 = $START.modelStatistics.electricPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] (0.0 = $START.modelStatistics.electricPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] (0.0 = $START.modelStatistics.electricPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] (0.0 = $START.modelStatistics.electricPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[14]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[13]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[12]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[11]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.other_demand = $START.Boiler.collectCosts.other_demand (0.0 = $START.Boiler.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.other_revenue = $START.Boiler.collectCosts.other_revenue (0.0 = $START.Boiler.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.H_demand = $START.Boiler.collectCosts.H_demand (0.0 = $START.Boiler.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.H_revenue = $START.Boiler.collectCosts.H_revenue (0.0 = $START.Boiler.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.Q_demand = $START.Boiler.collectCosts.Q_demand (0.0 = $START.Boiler.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.Q_revenue = $START.Boiler.collectCosts.Q_revenue (0.0 = $START.Boiler.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.W_el_demand = $START.Boiler.collectCosts.W_el_demand (0.0 = $START.Boiler.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.W_el_revenue = $START.Boiler.collectCosts.W_el_revenue (0.0 = $START.Boiler.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] (0.0 = $START.modelStatistics.electricPower.negSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] (0.0 = $START.modelStatistics.electricPower.negSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] (0.0 = $START.modelStatistics.electricPower.negSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] (0.0 = $START.modelStatistics.electricPower.negSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] (0.0 = $START.modelStatistics.electricPower.negSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] (0.0 = $START.modelStatistics.electricPower.negSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] (0.0 = $START.modelStatistics.electricPower.posSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] (0.0 = $START.modelStatistics.electricPower.posSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] (0.0 = $START.modelStatistics.electricPower.posSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] (0.0 = $START.modelStatistics.electricPower.posSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] (0.0 = $START.modelStatistics.electricPower.posSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] (0.0 = $START.modelStatistics.electricPower.posSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos (0.0 = $START.modelStatistics.electricPower.E_residual_pos) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg (0.0 = $START.modelStatistics.electricPower.E_residual_neg) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.m_CDE_consumed = $START.Boiler.collectCosts.m_CDE_consumed (0.0 = $START.Boiler.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.m_CDE_produced = $START.Boiler.collectCosts.m_CDE_produced (0.0 = $START.Boiler.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectHeatingPower.E = $START.Boiler.collectHeatingPower.E (0.0 = $START.Boiler.collectHeatingPower.E) Notification: Performance of analyzeInitialSystem (initialization): time 0.02673/3.219, allocations: 15.18 MB / 3.758 GB, free: 2.125 MB / 1.655 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0001773/3.219, allocations: 28 kB / 3.758 GB, free: 2.098 MB / 1.655 GB Notification: Performance of matching and sorting (n=743) (initialization): time 0.01918/3.238, allocations: 6.053 MB / 3.764 GB, free: 12.02 MB / 1.67 GB Notification: Performance of prepare postOptimizeDAE: time 0.000218/3.238, allocations: 73.7 kB / 3.764 GB, free: 11.95 MB / 1.67 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0004669/3.239, allocations: 163.9 kB / 3.764 GB, free: 11.79 MB / 1.67 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.0008715/3.239, allocations: 240.7 kB / 3.765 GB, free: 11.55 MB / 1.67 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.003973/3.243, allocations: 1.041 MB / 3.766 GB, free: 10.5 MB / 1.67 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.001364/3.245, allocations: 0.8952 MB / 3.767 GB, free: 9.582 MB / 1.67 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.007523/3.252, allocations: 235.9 kB / 3.767 GB, free: 9.352 MB / 1.67 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.001521/3.254, allocations: 392 kB / 3.767 GB, free: 8.969 MB / 1.67 GB Warning: Assuming fixed start value for the following 1 variables: Boiler.switch:DISCRETE(start = true fixed = true ) \"Boiler switch\" type: Boolean Warning: The initial conditions are over specified. The following 73 initial equations are redundant, so they are removed from the initialization system: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] Boiler.collectCosts.other_demand = $START.Boiler.collectCosts.other_demand Boiler.collectCosts.other_revenue = $START.Boiler.collectCosts.other_revenue Boiler.collectCosts.H_demand = $START.Boiler.collectCosts.H_demand Boiler.collectCosts.H_revenue = $START.Boiler.collectCosts.H_revenue Boiler.collectCosts.Q_demand = $START.Boiler.collectCosts.Q_demand Boiler.collectCosts.Q_revenue = $START.Boiler.collectCosts.Q_revenue Boiler.collectCosts.W_el_demand = $START.Boiler.collectCosts.W_el_demand Boiler.collectCosts.W_el_revenue = $START.Boiler.collectCosts.W_el_revenue modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg Boiler.collectCosts.m_CDE_consumed = $START.Boiler.collectCosts.m_CDE_consumed Boiler.collectCosts.m_CDE_produced = $START.Boiler.collectCosts.m_CDE_produced Boiler.collectHeatingPower.E = $START.Boiler.collectHeatingPower.E. Notification: Performance of preBalanceInitialSystem (initialization_lambda0): time 0.0117/3.266, allocations: 3.887 MB / 3.771 GB, free: 4.984 MB / 1.67 GB Notification: Performance of partitionIndependentBlocks (initialization_lambda0): time 0.007868/3.273, allocations: 4.478 MB / 3.775 GB, free: 15.06 MB / 1.686 GB Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] (0.0 = $START.modelStatistics.heatingPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] (0.0 = $START.modelStatistics.heatingPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] (0.0 = $START.modelStatistics.heatingPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] (0.0 = $START.modelStatistics.heatingPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] (0.0 = $START.modelStatistics.heatingPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] (0.0 = $START.modelStatistics.heatingPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] (0.0 = $START.modelStatistics.electricPower.negPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] (0.0 = $START.modelStatistics.electricPower.negPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] (0.0 = $START.modelStatistics.electricPower.negPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] (0.0 = $START.modelStatistics.electricPower.negPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] (0.0 = $START.modelStatistics.electricPower.negPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] (0.0 = $START.modelStatistics.electricPower.negPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] (0.0 = $START.modelStatistics.electricPower.posPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] (0.0 = $START.modelStatistics.electricPower.posPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] (0.0 = $START.modelStatistics.electricPower.posPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] (0.0 = $START.modelStatistics.electricPower.posPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] (0.0 = $START.modelStatistics.electricPower.posPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] (0.0 = $START.modelStatistics.electricPower.posPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] (0.0 = $START.modelStatistics.electricPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] (0.0 = $START.modelStatistics.electricPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] (0.0 = $START.modelStatistics.electricPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] (0.0 = $START.modelStatistics.electricPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] (0.0 = $START.modelStatistics.electricPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] (0.0 = $START.modelStatistics.electricPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[14]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[13]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[12]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[11]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.other_demand = $START.Boiler.collectCosts.other_demand (0.0 = $START.Boiler.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.other_revenue = $START.Boiler.collectCosts.other_revenue (0.0 = $START.Boiler.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.H_demand = $START.Boiler.collectCosts.H_demand (0.0 = $START.Boiler.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.H_revenue = $START.Boiler.collectCosts.H_revenue (0.0 = $START.Boiler.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.Q_demand = $START.Boiler.collectCosts.Q_demand (0.0 = $START.Boiler.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.Q_revenue = $START.Boiler.collectCosts.Q_revenue (0.0 = $START.Boiler.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.W_el_demand = $START.Boiler.collectCosts.W_el_demand (0.0 = $START.Boiler.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.W_el_revenue = $START.Boiler.collectCosts.W_el_revenue (0.0 = $START.Boiler.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] (0.0 = $START.modelStatistics.electricPower.negSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] (0.0 = $START.modelStatistics.electricPower.negSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] (0.0 = $START.modelStatistics.electricPower.negSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] (0.0 = $START.modelStatistics.electricPower.negSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] (0.0 = $START.modelStatistics.electricPower.negSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] (0.0 = $START.modelStatistics.electricPower.negSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] (0.0 = $START.modelStatistics.electricPower.posSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] (0.0 = $START.modelStatistics.electricPower.posSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] (0.0 = $START.modelStatistics.electricPower.posSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] (0.0 = $START.modelStatistics.electricPower.posSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] (0.0 = $START.modelStatistics.electricPower.posSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] (0.0 = $START.modelStatistics.electricPower.posSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos (0.0 = $START.modelStatistics.electricPower.E_residual_pos) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg (0.0 = $START.modelStatistics.electricPower.E_residual_neg) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.m_CDE_consumed = $START.Boiler.collectCosts.m_CDE_consumed (0.0 = $START.Boiler.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectCosts.m_CDE_produced = $START.Boiler.collectCosts.m_CDE_produced (0.0 = $START.Boiler.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: Boiler.collectHeatingPower.E = $START.Boiler.collectHeatingPower.E (0.0 = $START.Boiler.collectHeatingPower.E) Notification: Performance of analyzeInitialSystem (initialization_lambda0): time 0.02813/3.302, allocations: 15.13 MB / 3.79 GB, free: 13.18 MB / 1.702 GB Notification: Performance of solveInitialSystemEqSystem (initialization_lambda0): time 0.0001629/3.302, allocations: 28 kB / 3.79 GB, free: 13.16 MB / 1.702 GB Notification: Performance of matching and sorting (n=743) (initialization_lambda0): time 0.01913/3.321, allocations: 6.028 MB / 3.796 GB, free: 7.109 MB / 1.702 GB Notification: Performance of prepare postOptimizeDAE: time 0.0002265/3.321, allocations: 77.69 kB / 3.796 GB, free: 7.027 MB / 1.702 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0004857/3.322, allocations: 159.9 kB / 3.796 GB, free: 6.871 MB / 1.702 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.0007754/3.322, allocations: 220.8 kB / 3.796 GB, free: 6.652 MB / 1.702 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.00428/3.327, allocations: 1.037 MB / 3.797 GB, free: 5.613 MB / 1.702 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.001148/3.328, allocations: 0.8328 MB / 3.798 GB, free: 4.754 MB / 1.702 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.007906/3.336, allocations: 220 kB / 3.798 GB, free: 4.539 MB / 1.702 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.001541/3.337, allocations: 392 kB / 3.799 GB, free: 4.156 MB / 1.702 GB Warning: Assuming fixed start value for the following 1 variables: Boiler.switch:DISCRETE(start = true fixed = true ) \"Boiler switch\" type: Boolean Warning: The initial conditions are over specified. The following 73 initial equations are redundant, so they are removed from the initialization_lambda0 system: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] Boiler.collectCosts.other_demand = $START.Boiler.collectCosts.other_demand Boiler.collectCosts.other_revenue = $START.Boiler.collectCosts.other_revenue Boiler.collectCosts.H_demand = $START.Boiler.collectCosts.H_demand Boiler.collectCosts.H_revenue = $START.Boiler.collectCosts.H_revenue Boiler.collectCosts.Q_demand = $START.Boiler.collectCosts.Q_demand Boiler.collectCosts.Q_revenue = $START.Boiler.collectCosts.Q_revenue Boiler.collectCosts.W_el_demand = $START.Boiler.collectCosts.W_el_demand Boiler.collectCosts.W_el_revenue = $START.Boiler.collectCosts.W_el_revenue modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg Boiler.collectCosts.m_CDE_consumed = $START.Boiler.collectCosts.m_CDE_consumed Boiler.collectCosts.m_CDE_produced = $START.Boiler.collectCosts.m_CDE_produced Boiler.collectHeatingPower.E = $START.Boiler.collectHeatingPower.E. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 453 * Number of states: 0 () * Number of discrete variables: 13 ($PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$whenCondition2,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$whenCondition1,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$PRE.Boiler.switch,Boiler.greater.y,Boiler.switch) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (550): * Single equations (assignments): 524 * Array equations: 1 * Algorithm blocks: 1 * Record equations: 23 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 1 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 1 system {(1,8)} Notification: Performance of prepare postOptimizeDAE: time 0.003484/3.341, allocations: 1.194 MB / 3.8 GB, free: 2.855 MB / 1.702 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.003617/3.344, allocations: 0.8458 MB / 3.801 GB, free: 2.004 MB / 1.702 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.007461/3.352, allocations: 1.936 MB / 3.803 GB, free: 64 kB / 1.702 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.0001127/3.352, allocations: 39.94 kB / 3.803 GB, free: 24 kB / 1.702 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 2.628e-05/3.352, allocations: 12 kB / 3.803 GB, free: 12 kB / 1.702 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 6.148e-05/3.352, allocations: 20.02 kB / 3.803 GB, free: 15.99 MB / 1.717 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.01703/3.369, allocations: 4.22 MB / 3.807 GB, free: 11.73 MB / 1.717 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.0003544/3.369, allocations: 79.92 kB / 3.807 GB, free: 11.65 MB / 1.717 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.001143/3.37, allocations: 195.7 kB / 3.807 GB, free: 11.46 MB / 1.717 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.000594/3.371, allocations: 128.7 kB / 3.807 GB, free: 11.33 MB / 1.717 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0004904/3.372, allocations: 67.91 kB / 3.807 GB, free: 11.26 MB / 1.717 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.001038/3.373, allocations: 0.7084 MB / 3.808 GB, free: 10.53 MB / 1.717 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 1.623e-05/3.373, allocations: 15.94 kB / 3.808 GB, free: 10.51 MB / 1.717 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.009536/3.382, allocations: 3.096 MB / 3.811 GB, free: 7.219 MB / 1.717 GB Notification: Performance of postOpt removeConstants (simulation): time 0.006306/3.388, allocations: 1.424 MB / 3.812 GB, free: 5.77 MB / 1.717 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.003145/3.392, allocations: 43.98 kB / 3.813 GB, free: 5.727 MB / 1.717 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.004521/3.396, allocations: 68.02 kB / 3.813 GB, free: 5.66 MB / 1.717 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0006358/3.397, allocations: 152.2 kB / 3.813 GB, free: 5.512 MB / 1.717 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0004846/3.397, allocations: 95.97 kB / 3.813 GB, free: 5.418 MB / 1.717 GB Notification: Performance of sorting global known variables: time 0.02012/3.417, allocations: 5.637 MB / 3.818 GB, free: 15.83 MB / 1.733 GB Notification: Performance of sort global known variables: time 5.31e-07/3.417, allocations: 0 / 3.818 GB, free: 15.83 MB / 1.733 GB Notification: Performance of remove unused functions: time 0.01982/3.437, allocations: 2.5 MB / 3.821 GB, free: 13.33 MB / 1.733 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 45 * Number of states: 0 () * Number of discrete variables: 8 (Boiler.switch,Boiler.greater.y,$whenCondition2,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$whenCondition1,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled) * Number of discrete states: 5 (simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,Boiler.switch) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (121): * Single equations (assignments): 91 * Array equations: 1 * Algorithm blocks: 1 * Record equations: 23 * When equations: 4 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 1 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 1 system {(1,8)} [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:116:25-117:61:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:118:25-119:60:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:116:25-117:61:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:118:25-119:60:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:116:25-117:61:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:118:25-119:60:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so Notification: Performance of Backend phase and start with SimCode phase: time 0.008719/3.446, allocations: 2.271 MB / 3.823 GB, free: 11.57 MB / 1.733 GB Notification: Performance of simCode: created initialization part: time 0.01916/3.465, allocations: 7.527 MB / 3.83 GB, free: 3.773 MB / 1.733 GB Notification: Performance of simCode: created event and clocks part: time 1.837e-05/3.465, allocations: 0 / 3.83 GB, free: 3.773 MB / 1.733 GB Notification: Performance of simCode: created simulation system equations: time 0.003756/3.469, allocations: 1.705 MB / 3.832 GB, free: 1.914 MB / 1.733 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.01317/3.482, allocations: 1.134 MB / 3.833 GB, free: 0.793 MB / 1.733 GB Warning: The hideResult annotation could not be evaluated, probably due to missing annotation(Evaluate=true). It is removed. Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.03369/3.516, allocations: 12.55 MB / 3.845 GB, free: 4.062 MB / 1.749 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.008415/3.524, allocations: 3.95 MB / 3.849 GB, free: 88 kB / 1.749 GB Notification: Performance of simCode: alias equations: time 0.008144/3.532, allocations: 2.054 MB / 3.851 GB, free: 14.03 MB / 1.764 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.002462/3.535, allocations: 0.7331 MB / 3.852 GB, free: 13.29 MB / 1.764 GB Notification: Performance of SimCode: time 1.583e-06/3.535, allocations: 0 / 3.852 GB, free: 13.29 MB / 1.764 GB Notification: Performance of Templates: time 0.1657/3.7, allocations: 70.51 MB / 3.921 GB, free: 7.285 MB / 1.827 GB " [Timeout remaining time 656] make -j1 -f TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1.makefile [Timeout 660] make -j1 -f TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1.makefile clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:893:58: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] TILMedia_Gas_additionalProperties_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _gasPointer_ext, &_d_ext, &_kappa_ext, &_drhodp_hxi_ext, &_drhodh_pxi_ext, (double*) _drhodxi_ph_c89, (double*) _pp_c89, &_xi_gas_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:100:68: note: passing argument to parameter here void TILMedia_Gas_additionalProperties_pTxi(double, double, double*, void*, double*, double*, double*, double*, double*, double*, double*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:994:82: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _phi_ext = TILMedia_MoistAir_phi_pThumRatioxidg(_p_ext, _T_ext, _humRatio_ext, (const double*) _xi_dryGas_c89, _gasPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:98:76: note: passing argument to parameter here double TILMedia_MoistAir_phi_pThumRatioxidg(double, double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1025:81: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _humRatio_s_ext = TILMedia_Gas_saturationHumidityRatio_pTxidg(_p_ext, _T_ext, (const double*) _xi_dryGas_c89, _gasPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:97:75: note: passing argument to parameter here double TILMedia_Gas_saturationHumidityRatio_pTxidg(double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1054:74: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _xi_s_ext = TILMedia_Gas_saturationMassFraction_pTxidg(_p_ext, _T_ext, (const double*) _xi_dryGas_c89, _gasPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:96:74: note: passing argument to parameter here double TILMedia_Gas_saturationMassFraction_pTxidg(double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1092:64: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] TILMedia_Gas_simpleCondensingProperties_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _gasPointer_ext, &_cp_ext, &_cv_ext, &_beta_ext, &_w_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:95:74: note: passing argument to parameter here void TILMedia_Gas_simpleCondensingProperties_pTxi(double, double, double*, void*, double*, double*, double*, double*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1133:63: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _h_ext = TILMedia_Gas_specificEnthalpy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _gasPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:94:66: note: passing argument to parameter here double TILMedia_Gas_specificEnthalpy_pTxi(double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1162:62: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _s_ext = TILMedia_Gas_specificEntropy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _gasPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:93:65: note: passing argument to parameter here double TILMedia_Gas_specificEntropy_pTxi(double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1193:125: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _externalObject_ext = TILMedia_createExternalObject(MMC_STRINGDATA(_objectType), MMC_STRINGDATA(_mediumName), _flags_ext, (const double*) _xi_c89, _nc_ext, _condensingIndex_ext, MMC_STRINGDATA(_instanceName)); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:60:105: note: passing argument to parameter 'xi' here void* TILMedia_createExternalObject(const char* objectType, const char* mixtureName, int flags, double* xi, int _nc, int condensingIndex, const char* instanceName) { ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1236:74: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _d_ext = TILMedia_VLEFluidObjectFunctions_density_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:20:77: note: passing argument to parameter here double TILMedia_VLEFluidObjectFunctions_density_pTxi(double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1265:66: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _d_ext = TILMedia_VLEFluid_Cached_density_phxi(_p_ext, _h_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:19:69: note: passing argument to parameter here double TILMedia_VLEFluid_Cached_density_phxi(double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1294:83: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _h_ext = TILMedia_VLEFluidObjectFunctions_specificEnthalpy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:18:86: note: passing argument to parameter here double TILMedia_VLEFluidObjectFunctions_specificEnthalpy_pTxi(double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1323:82: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _s_ext = TILMedia_VLEFluidObjectFunctions_specificEntropy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:17:85: note: passing argument to parameter here double TILMedia_VLEFluidObjectFunctions_specificEntropy_pTxi(double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1352:82: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _s_ext = TILMedia_VLEFluidObjectFunctions_specificEntropy_phxi(_p_ext, _h_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:16:85: note: passing argument to parameter here double TILMedia_VLEFluidObjectFunctions_specificEntropy_phxi(double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1381:78: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _T_ext = TILMedia_VLEFluidObjectFunctions_temperature_phxi(_p_ext, _h_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:15:81: note: passing argument to parameter here double TILMedia_VLEFluidObjectFunctions_temperature_phxi(double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1410:90: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _cp_ext = TILMedia_VLEFluidFunctions_specificIsobaricHeatCapacity_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, MMC_STRINGDATA(_vleFluidName), _nc_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:14:92: note: passing argument to parameter here double TILMedia_VLEFluidFunctions_specificIsobaricHeatCapacity_pTxi(double, double, double*,const char*, int); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1480:56: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] TILMedia_VLEFluid_VLEProperties_phxi(_p_ext, _h_ext, (const double*) _xi_c89, _vleFluidPointer_ext, &_d_l_ext, &_h_l_ext, &_p_l_ext, &_s_l_ext, &_T_l_ext, (double*) _xi_l_c89, &_d_v_ext, &_h_v_ext, &_p_v_ext, &_s_v_ext, &_T_v_ext, (double*) _xi_v_c89); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:12:66: note: passing argument to parameter here void TILMedia_VLEFluid_VLEProperties_phxi(double, double, double*, void*, double*, double*, double*, double*, double*, double*, ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1583:63: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] TILMedia_VLEFluid_additionalProperties_phxi(_p_ext, _h_ext, (const double*) _xi_c89, _vleFluidPointer_ext, &_x_ext, &_cp_ext, &_cv_ext, &_beta_ext, &_kappa_ext, &_drhodp_ext, &_drhodh_ext, (double*) _drhodxi_c89, &_a_ext, &_gamma_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:11:73: note: passing argument to parameter here void TILMedia_VLEFluid_additionalProperties_phxi(double, double, double*, void*, double*, double*, double*, double*, double*, double*, double*, double*, double*, double*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:1656:37: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] TILMedia_VLEFluid_cricondenbar_xi((const double*) _xi_c89, _vleFluidPointer_ext, &_d_ext, &_h_ext, &_p_ext, &_s_ext, &_T_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:10:47: note: passing argument to parameter here void TILMedia_VLEFluid_cricondenbar_xi(double*, void*, double*, double*, double*, double*, double*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:2994:75: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _h_ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:8:78: note: passing argument to parameter here double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:3023:74: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _s_ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:7:77: note: passing argument to parameter here double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:3052:75: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _h_ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:8:78: note: passing argument to parameter here double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:3081:74: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _s_ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:7:77: note: passing argument to parameter here double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:3110:75: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _h_ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:8:78: note: passing argument to parameter here double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.c:3139:74: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _s_ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_includes.h:7:77: note: passing argument to parameter here double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ 24 warnings generated. clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_records.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_records.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_01exo.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_01exo.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_02nls.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_02nls.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_03lsy.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_03lsy.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_04set.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_04set.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_05evt.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_05evt.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_06inz.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_06inz.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_07dly.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_07dly.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_08bnd.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_08bnd.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_09alg.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_09alg.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_10asr.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_10asr.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_11mix.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_11mix.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_12jac.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_12jac.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_13opt.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_13opt.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_14lnz.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_14lnz.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_15syn.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_15syn.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_16dae.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_16dae.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_17inl.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_17inl.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_18spd.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_18spd.c clang -Os -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=TransiEnt_TransiEnt_Producer_Heat_Gas2Heat_SmallGasBoiler_Check_TestBoiler_HoldTemperature_static_L1 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_08bnd_part0.o TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_08bnd_part0.c TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_08bnd_part0.c:4045:180: error: passing 'TransiEnt_Basics_Media_Gases_Gas__ExhaustGas' to parameter of incompatible type 'TILMedia_GasTypes_BaseGas' (data->simulationInfo->realParameter[150] /* Boiler.combustion.M_i_exh[9] PARAM */) = real_get(omc_TransiEnt_Basics_Functions_GasProperties_getMolarMasses__idealGas(threadData, tmp15, ((modelica_integer) 9)), 8); ^~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.h:997:134: note: passing argument to parameter '_gasType' here real_array omc_TransiEnt_Basics_Functions_GasProperties_getMolarMasses__idealGas(threadData_t *threadData, TILMedia_GasTypes_BaseGas _gasType, modelica_integer _nc); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_08bnd_part0.c:4070:180: error: passing 'TransiEnt_Basics_Media_Gases_Gas__ExhaustGas' to parameter of incompatible type 'TILMedia_GasTypes_BaseGas' (data->simulationInfo->realParameter[143] /* Boiler.combustion.M_i_exh[2] PARAM */) = real_get(omc_TransiEnt_Basics_Functions_GasProperties_getMolarMasses__idealGas(threadData, tmp16, ((modelica_integer) 9)), 1); ^~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.h:997:134: note: passing argument to parameter '_gasType' here real_array omc_TransiEnt_Basics_Functions_GasProperties_getMolarMasses__idealGas(threadData_t *threadData, TILMedia_GasTypes_BaseGas _gasType, modelica_integer _nc); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_08bnd_part0.c:4095:180: error: passing 'TransiEnt_Basics_Media_Gases_Gas__ExhaustGas' to parameter of incompatible type 'TILMedia_GasTypes_BaseGas' (data->simulationInfo->realParameter[142] /* Boiler.combustion.M_i_exh[1] PARAM */) = real_get(omc_TransiEnt_Basics_Functions_GasProperties_getMolarMasses__idealGas(threadData, tmp17, ((modelica_integer) 9)), 0); ^~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.h:997:134: note: passing argument to parameter '_gasType' here real_array omc_TransiEnt_Basics_Functions_GasProperties_getMolarMasses__idealGas(threadData_t *threadData, TILMedia_GasTypes_BaseGas _gasType, modelica_integer _nc); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_08bnd_part0.c:4134:180: error: passing 'TransiEnt_Basics_Media_Gases_Gas__MoistAir' to parameter of incompatible type 'TILMedia_GasTypes_BaseGas' (data->simulationInfo->realParameter[141] /* Boiler.combustion.M_i_air[3] PARAM */) = real_get(omc_TransiEnt_Basics_Functions_GasProperties_getMolarMasses__idealGas(threadData, tmp18, ((modelica_integer) 3)), 2); ^~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.h:997:134: note: passing argument to parameter '_gasType' here real_array omc_TransiEnt_Basics_Functions_GasProperties_getMolarMasses__idealGas(threadData_t *threadData, TILMedia_GasTypes_BaseGas _gasType, modelica_integer _nc); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_08bnd_part0.c:4159:180: error: passing 'TransiEnt_Basics_Media_Gases_Gas__MoistAir' to parameter of incompatible type 'TILMedia_GasTypes_BaseGas' (data->simulationInfo->realParameter[140] /* Boiler.combustion.M_i_air[2] PARAM */) = real_get(omc_TransiEnt_Basics_Functions_GasProperties_getMolarMasses__idealGas(threadData, tmp19, ((modelica_integer) 3)), 1); ^~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.h:997:134: note: passing argument to parameter '_gasType' here real_array omc_TransiEnt_Basics_Functions_GasProperties_getMolarMasses__idealGas(threadData_t *threadData, TILMedia_GasTypes_BaseGas _gasType, modelica_integer _nc); ^ TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_08bnd_part0.c:4184:180: error: passing 'TransiEnt_Basics_Media_Gases_Gas__MoistAir' to parameter of incompatible type 'TILMedia_GasTypes_BaseGas' (data->simulationInfo->realParameter[139] /* Boiler.combustion.M_i_air[1] PARAM */) = real_get(omc_TransiEnt_Basics_Functions_GasProperties_getMolarMasses__idealGas(threadData, tmp20, ((modelica_integer) 3)), 0); ^~~~~ ./TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_functions.h:997:134: note: passing argument to parameter '_gasType' here real_array omc_TransiEnt_Basics_Functions_GasProperties_getMolarMasses__idealGas(threadData_t *threadData, TILMedia_GasTypes_BaseGas _gasType, modelica_integer _nc); ^ 6 errors generated. make: *** [: TransiEnt_TransiEnt.Producer.Heat.Gas2Heat.SmallGasBoiler.Check.TestBoiler_HoldTemperature_static_L1_08bnd_part0.o] Error 1 [Calling os._exit(0), Time elapsed: 24.47698691021651]