Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr TransiEnt_TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCyc2Source4Pipes2Sinks.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo", uses=false) Using package TransiEnt with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo) Using package DataFiles with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo) Using package Design with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo) Using package Modelica_LinearSystems2 with version 2.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo) Using package ModelicaReference with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo) Using package TILMedia with version 1.8.1 ClaRa (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo) Using package ClaRa with version 1.8.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo) Using package DymolaCommands with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo) Using package Buildings with version 9.1.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo) Running command: translateModel(TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCyc2Source4Pipes2Sinks,tolerance=1e-06,outputFormat="empty",numberOfIntervals=3600,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCyc2Source4Pipes2Sinks") translateModel(TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCyc2Source4Pipes2Sinks,tolerance=1e-06,outputFormat="empty",numberOfIntervals=3600,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCyc2Source4Pipes2Sinks") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo): time 2.318/2.318, allocations: 390.2 MB / 409.3 MB, free: 12.54 MB / 318.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo): time 0.0006027/0.0006028, allocations: 35.89 kB / 0.4892 GB, free: 4.609 MB / 398.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestReheater, which is expected to be stored in file TestReheater.mo, but seems to be named testReheater.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/testReheater.mo:2:1-117:17:writable] Warning: Expected the package to have name testReheater, but got TestReheater. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/package.mo:2:1-23:10:writable] Warning: PhysicalMills was referenced in the package.order file, but was not found in package.mo, PhysicalMills/package.mo or PhysicalMills.mo. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: Expected the package to have name physicalMills, but got PhysicalMills. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4_advancedInit, which is expected to be stored in file Mill_L4_advancedInit.mo, but seems to be named mill_L4_advancedInit.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4, which is expected to be stored in file Mill_L4.mo, but seems to be named mill_L4.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have name mill_L4_advancedInit, but got Mill_L4_advancedInit. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have name mill_L4, but got Mill_L4. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_2, which is expected to be stored in file TestMillBox_2.mo, but seems to be named testMillBox_2.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1_measurementInput, which is expected to be stored in file TestMillBox_1_measurementInput.mo, but seems to be named testMillBox_1_measurementInput.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1, which is expected to be stored in file TestMillBox_1.mo, but seems to be named testMillBox_1.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have name testMillBox_2, but got TestMillBox_2. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have name testMillBox_1_measurementInput, but got TestMillBox_1_measurementInput. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have name testMillBox_1, but got TestMillBox_1. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/package.mo:2:1-29:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FlowClassifier.mo:2:1-346:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/CentrifugalClassifier.mo:2:1-380:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/GrinderRingRoller.mo:2:1-294:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FuelJoin_distributed.mo:2:1-133:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Dryer.mo:2:1-301:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/package.mo:2:1-20:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/package.mo:2:1-20:13:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_complex.mo:2:1-71:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_constant.mo:2:1-49:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_base.mo:2:1-52:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Kersting.mo:2:1-80:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Steinmetz.mo:2:1-104:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_constant.mo:2:1-45:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_base.mo:2:1-50:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/package.mo:2:1-20:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Austin.mo:2:1-109:20:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Steinmetz.mo:2:1-106:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_constant.mo:2:1-45:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_base.mo:2:1-51:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/package.mo:2:1-20:11:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_ideal.mo:2:1-58:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_base.mo:2:1-44:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/package.mo:2:1-20:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow.mo:2:1-111:21:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal.mo:2:1-153:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal_base.mo:2:1-45:33:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow_base.mo:2:1-45:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/package.mo:2:1-20:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Dryer.mo:2:1-57:15:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_FlowClassifier.mo:2:1-67:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_CentrifugalClassifier.mo:2:1-69:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Grinder.mo:2:1-61:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_21classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/GeometricProgression.mo:2:1-56:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_generic.mo:2:1-43:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_05classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_11classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_base.mo:2:1-61:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestFuelJoin, which is expected to be stored in file TestFuelJoin.mo, but seems to be named testFuelJoin.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestAerosolVolume, which is expected to be stored in file TestAerosolVolume.mo, but seems to be named testAerosolVolume.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestDryer, which is expected to be stored in file TestDryer.mo, but seems to be named testDryer.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestGrinder, which is expected to be stored in file TestGrinder.mo, but seems to be named testGrinder.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have name testFuelJoin, but got TestFuelJoin. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have name testAerosolVolume, but got TestAerosolVolume. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have name testDryer, but got TestDryer. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have name testGrinder, but got TestGrinder. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo): time 0.7716/0.7716, allocations: 127.2 MB / 0.703 GB, free: 5.395 MB / 0.4981 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo): time 0.1104/0.1104, allocations: 22.37 MB / 0.8397 GB, free: 16.36 MB / 0.5294 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo): time 0.01283/0.01283, allocations: 0.8836 MB / 0.9617 GB, free: 3.324 MB / 0.6388 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo): time 0.2703/0.2703, allocations: 45.02 MB / 1.127 GB, free: 97.68 MB / 0.6544 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo): time 0.1058/0.1058, allocations: 13.56 MB / 1.27 GB, free: 93.55 MB / 0.6544 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001712/0.001712, allocations: 99.53 kB / 1.403 GB, free: 7.059 MB / 0.7013 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001459/0.00146, allocations: 191.3 kB / 1.536 GB, free: 222.8 MB / 0.8263 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.832/1.832, allocations: 222.8 MB / 1.887 GB, free: 91.83 MB / 0.8888 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo): time 0.0006316/0.0006316, allocations: 27.91 kB / 2.068 GB, free: 15.05 MB / 0.92 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo): time 0.0006402/0.0006403, allocations: 35.88 kB / 2.249 GB, free: 5.246 MB / 1.092 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo): time 1.118/1.118, allocations: 220.8 MB / 2.646 GB, free: 132.1 MB / 1.123 GB Warning: Requested package TILMedia of version 1.8.0 ClaRa, but this package was already loaded with version 1.8.1 ClaRa. OpenModelica cannot reason about compatibility between the two packages since they are not semantic versions. Warning: TransiEnt requested package ClaRa of version 1.8.0. ClaRa 1.8.1 is used instead which states that it is only compatible with a conversion script. Use convertPackageToLibrary(TransiEnt, ClaRa, "1.8.1") to run the conversion script or proceed with potential issues as a result. Notification: TransiEnt requested package Buildings of version 9.0.0. Buildings 9.1.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.004856/0.004856, allocations: 303.5 kB / 3.119 GB, free: 9.617 MB / 1.233 GB Notification: Performance of FrontEnd - Absyn->SCode: time 2.767/2.772, allocations: 229.5 MB / 3.343 GB, free: 5.961 MB / 1.405 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Pipes/PipeFlow_L4_Simple.mo:96:3-96:50:writable] Warning: An inner declaration for outer component modelStatistics could not be found and was automatically generated. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Pipes/PipeFlow_L4_Simple.mo:96:3-96:50:writable] Notification: The diagnostics message for the missing inner is: Your model is using an outer "modelStatistics" but it does not contain an inner "modelStatistics" component. Drag model TransiEnt.ModelStatistics into your model to make it work. Notification: Performance of NFInst.instantiate(TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCyc2Source4Pipes2Sinks): time 0.1191/2.891, allocations: 79.73 MB / 3.421 GB, free: 500 kB / 1.452 GB Notification: Performance of NFInst.instExpressions: time 0.08902/2.981, allocations: 33.7 MB / 3.454 GB, free: 4.863 MB / 1.483 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.02842/3.009, allocations: 285.2 kB / 3.454 GB, free: 4.793 MB / 1.483 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:56:3-62:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:63:3-73:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:56:3-62:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:63:3-73:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:56:3-62:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:63:3-73:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:56:3-62:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:63:3-73:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Source_yellow.mo:44:3-54:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Sink_yellow.mo:43:3-49:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:47:3-53:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:54:3-64:27:writable] Warning: Connector outlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:65:3-75:26:writable] Warning: Connector outlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:47:3-53:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:54:3-64:27:writable] Warning: Connector outlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:65:3-75:26:writable] Warning: Connector outlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:54:3-61:73:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:62:3-68:27:writable] Warning: Connector inlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:69:3-78:26:writable] Warning: Connector inlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:54:3-61:73:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:62:3-68:27:writable] Warning: Connector inlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:69:3-78:26:writable] Warning: Connector inlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:48:3-54:27:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:55:3-64:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:48:3-54:27:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:55:3-64:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:56:3-62:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:63:3-73:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:56:3-62:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:63:3-73:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:56:3-62:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:63:3-73:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:56:3-62:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:63:3-73:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Source_yellow.mo:44:3-54:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Sink_yellow.mo:43:3-49:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:47:3-53:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:54:3-64:27:writable] Warning: Connector outlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:65:3-75:26:writable] Warning: Connector outlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:47:3-53:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:54:3-64:27:writable] Warning: Connector outlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:65:3-75:26:writable] Warning: Connector outlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:54:3-61:73:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:62:3-68:27:writable] Warning: Connector inlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:69:3-78:26:writable] Warning: Connector inlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:54:3-61:73:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:62:3-68:27:writable] Warning: Connector inlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:69:3-78:26:writable] Warning: Connector inlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:48:3-54:27:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:55:3-64:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:48:3-54:27:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:55:3-64:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:85:3-85:105:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:86:3-86:112:writable] Warning: Connector primBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:87:3-87:102:writable] Warning: Connector primBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:88:3-88:111:writable] Warning: Connector secBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:89:3-89:101:writable] Warning: Connector secBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:90:3-90:92:writable] Warning: Connector surroundingGridLoad is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:92:3-92:126:writable] Warning: Connector tielinePowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:93:3-93:130:writable] Warning: Connector tielineSetPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:95:3-95:95:writable] Warning: Connector kineticEnergyCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:98:3-98:99:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:100:3-100:107:writable] Warning: Connector gwpCollectorHeat is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:103:3-103:82:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:3-105:87:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). Notification: Performance of NFTyping.typeComponents: time 0.02526/3.034, allocations: 7.2 MB / 3.461 GB, free: 15.78 MB / 1.499 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/VLEFluidFunctions.mo:177:13-181:19:writable] Warning: Pure function 'TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidFunctions.density_phxi' contains a call to impure function 'TILMedia.Internals.VLEFluidFunctions.density_phxi'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/fullPathName.mo:2:1-78:17:writable] Warning: Pure function 'TransiEnt.Basics.Functions.fullPathName' contains a call to impure function 'Modelica.Utilities.Streams.print'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/VLEFluidFunctions.mo:524:13-528:28:writable] Warning: Pure function 'TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidFunctions.specificEnthalpy_pTxi' contains a call to impure function 'TILMedia.Internals.VLEFluidFunctions.specificEnthalpy_pTxi'. Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil as Integer: 9. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others as Integer: 10. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Storage as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Storage) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Notification: Performance of NFTyping.typeBindings: time 0.03729/3.072, allocations: 10.15 MB / 3.471 GB, free: 7.023 MB / 1.499 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/GasProperties/verboseXi.mo:2:1-93:14:writable] Warning: Pure function 'TransiEnt.Basics.Functions.GasProperties.verboseXi' contains a call to impure function 'Modelica.Utilities.Streams.print'. Notification: Performance of NFTyping.typeClassSections: time 0.0292/3.101, allocations: 9.513 MB / 3.48 GB, free: 13.54 MB / 1.514 GB Notification: Performance of NFFlatten.flatten: time 0.07317/3.174, allocations: 43.58 MB / 3.523 GB, free: 1.848 MB / 1.545 GB Notification: Performance of NFFlatten.resolveConnections: time 0.04147/3.216, allocations: 22.64 MB / 3.545 GB, free: 11.07 MB / 1.577 GB Notification: Performance of NFEvalConstants.evaluate: time 0.04121/3.257, allocations: 18.32 MB / 3.563 GB, free: 8.699 MB / 1.592 GB Notification: Performance of NFSimplifyModel.simplify: time 0.04626/3.303, allocations: 28.66 MB / 3.591 GB, free: 11.96 MB / 1.624 GB Notification: Performance of NFPackage.collectConstants: time 0.02842/3.332, allocations: 5.891 MB / 3.597 GB, free: 6.074 MB / 1.624 GB Notification: Performance of NFFlatten.collectFunctions: time 0.03104/3.363, allocations: 7.155 MB / 3.604 GB, free: 14.92 MB / 1.639 GB Notification: Performance of NFScalarize.scalarize: time 0.04594/3.409, allocations: 30.3 MB / 3.633 GB, free: 0.5547 MB / 1.655 GB Notification: Performance of NFVerifyModel.verify: time 0.06964/3.478, allocations: 31.86 MB / 3.664 GB, free: 0.5547 MB / 1.686 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:79:53-79:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:83:53-83:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/EconomicStatistics.mo:42:70-42:85:writable] Error: Variable True not found in scope EconomicStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:71-105:86:writable] Error: Variable True not found in scope ModelStatistics. Notification: Performance of NFConvertDAE.convert: time 0.143/3.621, allocations: 101.7 MB / 3.764 GB, free: 10.54 MB / 1.795 GB Notification: Performance of FrontEnd - DAE generated: time 7.885e-06/3.621, allocations: 0 / 3.764 GB, free: 10.54 MB / 1.795 GB Notification: Performance of FrontEnd: time 2.695e-06/3.621, allocations: 3.938 kB / 3.764 GB, free: 10.54 MB / 1.795 GB Notification: Performance of Transformations before backend: time 0.002881/3.624, allocations: 0 / 3.764 GB, free: 10.54 MB / 1.795 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 8343 * Number of variables: 8343 Notification: Performance of Generate backend data structure: time 0.2256/3.85, allocations: 71.82 MB / 3.834 GB, free: 2.285 MB / 1.858 GB Notification: Performance of prepare preOptimizeDAE: time 4.991e-05/3.85, allocations: 8.031 kB / 3.834 GB, free: 2.277 MB / 1.858 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.03042/3.88, allocations: 6.047 MB / 3.84 GB, free: 12.19 MB / 1.874 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.1809/4.061, allocations: 67.15 MB / 3.905 GB, free: 8.809 MB / 1.936 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.002037/4.063, allocations: 1.434 MB / 3.907 GB, free: 7.367 MB / 1.936 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.01744/4.081, allocations: 1.987 MB / 3.909 GB, free: 5.379 MB / 1.936 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.1862/4.267, allocations: 74.42 MB / 3.981 GB, free: 4.422 MB / 2.014 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.001426/4.269, allocations: 150.6 kB / 3.981 GB, free: 4.273 MB / 2.014 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.02365/4.292, allocations: 0.992 MB / 3.982 GB, free: 3.281 MB / 2.014 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.006531/4.299, allocations: 3.519 MB / 3.986 GB, free: 15.75 MB / 2.03 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.1587/4.458, allocations: 75.97 MB / 4.06 GB, free: 3.727 MB / 2.092 GB Notification: Performance of preOpt removeSimpleEquations (simulation): time 2.05/6.508, allocations: 280.1 MB / 4.334 GB, free: 342.7 MB / 2.092 GB Notification: Performance of preOpt comSubExp (simulation): time 0.06962/6.577, allocations: 45.08 MB / 4.378 GB, free: 296.6 MB / 2.092 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.05686/6.634, allocations: 40.12 MB / 4.417 GB, free: 256.1 MB / 2.092 GB Notification: Performance of preOpt evalFunc (simulation): time 0.2032/6.838, allocations: 95.7 MB / 4.51 GB, free: 161.6 MB / 2.092 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.08387/6.922, allocations: 43.34 MB / 4.553 GB, free: 117.4 MB / 2.092 GB Notification: Performance of pre-optimization done (n=4340): time 9.917e-05/6.922, allocations: 4 kB / 4.553 GB, free: 117.4 MB / 2.092 GB Notification: Performance of matching and sorting (n=4364): time 8.305/15.23, allocations: 1.65 GB / 6.203 GB, free: 0.5365 GB / 2.405 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.00219/15.23, allocations: 6.848 MB / 6.209 GB, free: 0.5284 GB / 2.405 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.123/15.35, allocations: 45.02 MB / 6.253 GB, free: 0.4924 GB / 2.405 GB Notification: Performance of collectPreVariables (initialization): time 0.01434/15.37, allocations: 0.5039 MB / 6.254 GB, free: 0.4919 GB / 2.405 GB Notification: Performance of collectInitialEqns (initialization): time 0.03195/15.4, allocations: 20.82 MB / 6.274 GB, free: 485.9 MB / 2.405 GB Notification: Performance of collectInitialBindings (initialization): time 0.031/15.43, allocations: 15.65 MB / 6.289 GB, free: 473.7 MB / 2.405 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.0651/15.49, allocations: 9.584 MB / 6.299 GB, free: 465.1 MB / 2.405 GB Notification: Performance of setup shared object (initialization): time 7.47e-05/15.49, allocations: 301.1 kB / 6.299 GB, free: 464.9 MB / 2.405 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.07441/15.57, allocations: 38.8 MB / 6.337 GB, free: 427 MB / 2.405 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.08265/15.65, allocations: 48.54 MB / 6.384 GB, free: 375.2 MB / 2.405 GB Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] (0.0 = $START.modelStatistics.heatingPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] (0.0 = $START.modelStatistics.heatingPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] (0.0 = $START.modelStatistics.heatingPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] (0.0 = $START.modelStatistics.heatingPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] (0.0 = $START.modelStatistics.heatingPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] (0.0 = $START.modelStatistics.heatingPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] (0.0 = $START.modelStatistics.electricPower.negPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] (0.0 = $START.modelStatistics.electricPower.negPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] (0.0 = $START.modelStatistics.electricPower.negPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] (0.0 = $START.modelStatistics.electricPower.negPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] (0.0 = $START.modelStatistics.electricPower.negPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] (0.0 = $START.modelStatistics.electricPower.negPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] (0.0 = $START.modelStatistics.electricPower.posPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] (0.0 = $START.modelStatistics.electricPower.posPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] (0.0 = $START.modelStatistics.electricPower.posPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] (0.0 = $START.modelStatistics.electricPower.posPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] (0.0 = $START.modelStatistics.electricPower.posPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] (0.0 = $START.modelStatistics.electricPower.posPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] (0.0 = $START.modelStatistics.electricPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] (0.0 = $START.modelStatistics.electricPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] (0.0 = $START.modelStatistics.electricPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] (0.0 = $START.modelStatistics.electricPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] (0.0 = $START.modelStatistics.electricPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] (0.0 = $START.modelStatistics.electricPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[14]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[13]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[12]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[11]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.other_demand = $START.pipe3.collectCosts.other_demand (0.0 = $START.pipe3.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.other_revenue = $START.pipe3.collectCosts.other_revenue (0.0 = $START.pipe3.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.H_demand = $START.pipe3.collectCosts.H_demand (0.0 = $START.pipe3.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.H_revenue = $START.pipe3.collectCosts.H_revenue (0.0 = $START.pipe3.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.Q_demand = $START.pipe3.collectCosts.Q_demand (0.0 = $START.pipe3.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.Q_revenue = $START.pipe3.collectCosts.Q_revenue (0.0 = $START.pipe3.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.W_el_demand = $START.pipe3.collectCosts.W_el_demand (0.0 = $START.pipe3.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.W_el_revenue = $START.pipe3.collectCosts.W_el_revenue (0.0 = $START.pipe3.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.other_demand = $START.pipe4.collectCosts.other_demand (0.0 = $START.pipe4.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.other_revenue = $START.pipe4.collectCosts.other_revenue (0.0 = $START.pipe4.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.H_demand = $START.pipe4.collectCosts.H_demand (0.0 = $START.pipe4.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.H_revenue = $START.pipe4.collectCosts.H_revenue (0.0 = $START.pipe4.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.Q_demand = $START.pipe4.collectCosts.Q_demand (0.0 = $START.pipe4.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.Q_revenue = $START.pipe4.collectCosts.Q_revenue (0.0 = $START.pipe4.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.W_el_demand = $START.pipe4.collectCosts.W_el_demand (0.0 = $START.pipe4.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.W_el_revenue = $START.pipe4.collectCosts.W_el_revenue (0.0 = $START.pipe4.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.other_demand = $START.pipe2.collectCosts.other_demand (0.0 = $START.pipe2.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.other_revenue = $START.pipe2.collectCosts.other_revenue (0.0 = $START.pipe2.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.H_demand = $START.pipe2.collectCosts.H_demand (0.0 = $START.pipe2.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.H_revenue = $START.pipe2.collectCosts.H_revenue (0.0 = $START.pipe2.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.Q_demand = $START.pipe2.collectCosts.Q_demand (0.0 = $START.pipe2.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.Q_revenue = $START.pipe2.collectCosts.Q_revenue (0.0 = $START.pipe2.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.W_el_demand = $START.pipe2.collectCosts.W_el_demand (0.0 = $START.pipe2.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.W_el_revenue = $START.pipe2.collectCosts.W_el_revenue (0.0 = $START.pipe2.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.other_demand = $START.pipe1.collectCosts.other_demand (0.0 = $START.pipe1.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.other_revenue = $START.pipe1.collectCosts.other_revenue (0.0 = $START.pipe1.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.H_demand = $START.pipe1.collectCosts.H_demand (0.0 = $START.pipe1.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.H_revenue = $START.pipe1.collectCosts.H_revenue (0.0 = $START.pipe1.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.Q_demand = $START.pipe1.collectCosts.Q_demand (0.0 = $START.pipe1.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.Q_revenue = $START.pipe1.collectCosts.Q_revenue (0.0 = $START.pipe1.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.W_el_demand = $START.pipe1.collectCosts.W_el_demand (0.0 = $START.pipe1.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.W_el_revenue = $START.pipe1.collectCosts.W_el_revenue (0.0 = $START.pipe1.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] (0.0 = $START.modelStatistics.electricPower.negSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] (0.0 = $START.modelStatistics.electricPower.negSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] (0.0 = $START.modelStatistics.electricPower.negSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] (0.0 = $START.modelStatistics.electricPower.negSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] (0.0 = $START.modelStatistics.electricPower.negSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] (0.0 = $START.modelStatistics.electricPower.negSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] (0.0 = $START.modelStatistics.electricPower.posSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] (0.0 = $START.modelStatistics.electricPower.posSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] (0.0 = $START.modelStatistics.electricPower.posSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] (0.0 = $START.modelStatistics.electricPower.posSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] (0.0 = $START.modelStatistics.electricPower.posSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] (0.0 = $START.modelStatistics.electricPower.posSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos (0.0 = $START.modelStatistics.electricPower.E_residual_pos) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg (0.0 = $START.modelStatistics.electricPower.E_residual_neg) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.m_CDE_consumed = $START.pipe3.collectCosts.m_CDE_consumed (0.0 = $START.pipe3.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.m_CDE_produced = $START.pipe3.collectCosts.m_CDE_produced (0.0 = $START.pipe3.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.m_CDE_consumed = $START.pipe4.collectCosts.m_CDE_consumed (0.0 = $START.pipe4.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.m_CDE_produced = $START.pipe4.collectCosts.m_CDE_produced (0.0 = $START.pipe4.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.m_CDE_consumed = $START.pipe2.collectCosts.m_CDE_consumed (0.0 = $START.pipe2.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.m_CDE_produced = $START.pipe2.collectCosts.m_CDE_produced (0.0 = $START.pipe2.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.m_CDE_consumed = $START.pipe1.collectCosts.m_CDE_consumed (0.0 = $START.pipe1.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.m_CDE_produced = $START.pipe1.collectCosts.m_CDE_produced (0.0 = $START.pipe1.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: sink1.m = $START.sink1.m (0.0 = $START.sink1.m) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: sink2.m = $START.sink2.m (0.0 = $START.sink2.m) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: source1.m = $START.source1.m (0.0 = $START.source1.m) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: source2.m = $START.source2.m (0.0 = $START.source2.m) Notification: Performance of analyzeInitialSystem (initialization): time 2.648/18.3, allocations: 367.3 MB / 6.743 GB, free: 0.761 GB / 2.405 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0008146/18.3, allocations: 76.44 kB / 6.743 GB, free: 0.761 GB / 2.405 GB Notification: Performance of matching and sorting (n=6843) (initialization): time 0.2637/18.56, allocations: 99.04 MB / 6.84 GB, free: 0.7307 GB / 2.405 GB Notification: Performance of prepare postOptimizeDAE: time 0.0006431/18.56, allocations: 118.5 kB / 6.84 GB, free: 0.7307 GB / 2.405 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.003833/18.57, allocations: 1.004 MB / 6.841 GB, free: 0.7307 GB / 2.405 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.01445/18.58, allocations: 5.19 MB / 6.846 GB, free: 0.7294 GB / 2.405 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.07341/18.66, allocations: 10.21 MB / 6.856 GB, free: 0.7286 GB / 2.405 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.06469/18.72, allocations: 88.25 MB / 6.942 GB, free: 0.6518 GB / 2.405 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.06232/18.78, allocations: 1.778 MB / 6.944 GB, free: 0.6509 GB / 2.405 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.01828/18.8, allocations: 2.011 MB / 6.946 GB, free: 0.6505 GB / 2.405 GB Warning: Assuming fixed start value for the following 69 variables: realGasCompositionByWtFractions_stepVariationXi_1_1.t_lastchange:VARIABLE(start = 0.0 unit = "s" fixed = true ) type: Real pipe1.h[1]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[1] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[2]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[2] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[3]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[3] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[4]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[4] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[5]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[5] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[6]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[6] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[7]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[7] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[8]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[8] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[9]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[9] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[10]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[10] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.p[1]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[1] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[2]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[2] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[3]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[3] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[4]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[4] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[5]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[5] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[6]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[6] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[7]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[7] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[8]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[8] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[9]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[9] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[10]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[10] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe2.h[1]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[1] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe2.h[2]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[2] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe2.h[3]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[3] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe2.h[4]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[4] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe2.p[1]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[1] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] pipe2.p[2]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[2] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] pipe2.p[3]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[3] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] pipe2.p[4]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[4] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] pipe4.h[1]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[1] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[2]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[2] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[3]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[3] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[4]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[4] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[5]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[5] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[6]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[6] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[7]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[7] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[8]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[8] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[9]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[9] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[10]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[10] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.p[1]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[1] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[2]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[2] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[3]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[3] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[4]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[4] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[5]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[5] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[6]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[6] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[7]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[7] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[8]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[8] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[9]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[9] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[10]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[10] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe3.h[1]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[1] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe3.h[2]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[2] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe3.h[3]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[3] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe3.h[4]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[4] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe3.p[1]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[1] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] pipe3.p[2]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[2] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] pipe3.p[3]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[3] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] pipe3.p[4]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[4] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] split1.h:VARIABLE(start = Init.split1.h_in unit = "J/kg" fixed = true nominal = 1000.0 ) "Specific enthalpy" type: Real mix2.h:VARIABLE(start = Init.mix2.h_out unit = "J/kg" fixed = true nominal = 1000.0 ) "Specific enthalpy" type: Real mix2.p:VARIABLE(min = 0.0 start = Init.mix2.p unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real split2.h:VARIABLE(start = Init.split2.h_in unit = "J/kg" fixed = true nominal = 1000.0 ) "Specific enthalpy" type: Real mix1.h:VARIABLE(start = Init.mix1.h_out unit = "J/kg" fixed = true nominal = 1000.0 ) "Specific enthalpy" type: Real mix1.p:VARIABLE(min = 0.0 start = Init.mix1.p unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[1]:VARIABLE(min = 0.0 max = 1.0 start = 0.722090178 unit = "1" fixed = true ) type: Real [6] realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[2]:VARIABLE(min = 0.0 max = 1.0 start = 0.139591715 unit = "1" fixed = true ) type: Real [6] realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[3]:VARIABLE(min = 0.0 max = 1.0 start = 0.069014479 unit = "1" fixed = true ) type: Real [6] realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[4]:VARIABLE(min = 0.0 max = 1.0 start = 0.019245659 unit = "1" fixed = true ) type: Real [6] realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[5]:VARIABLE(min = 0.0 max = 1.0 start = 0.026650142 unit = "1" fixed = true ) type: Real [6] realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[6]:VARIABLE(min = 0.0 max = 1.0 start = 0.023407827 unit = "1" fixed = true ) type: Real [6] Warning: The initial conditions are over specified. The following 106 initial equations are redundant, so they are removed from the initialization system: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] pipe3.collectCosts.other_demand = $START.pipe3.collectCosts.other_demand pipe3.collectCosts.other_revenue = $START.pipe3.collectCosts.other_revenue pipe3.collectCosts.H_demand = $START.pipe3.collectCosts.H_demand pipe3.collectCosts.H_revenue = $START.pipe3.collectCosts.H_revenue pipe3.collectCosts.Q_demand = $START.pipe3.collectCosts.Q_demand pipe3.collectCosts.Q_revenue = $START.pipe3.collectCosts.Q_revenue pipe3.collectCosts.W_el_demand = $START.pipe3.collectCosts.W_el_demand pipe3.collectCosts.W_el_revenue = $START.pipe3.collectCosts.W_el_revenue pipe4.collectCosts.other_demand = $START.pipe4.collectCosts.other_demand pipe4.collectCosts.other_revenue = $START.pipe4.collectCosts.other_revenue pipe4.collectCosts.H_demand = $START.pipe4.collectCosts.H_demand pipe4.collectCosts.H_revenue = $START.pipe4.collectCosts.H_revenue pipe4.collectCosts.Q_demand = $START.pipe4.collectCosts.Q_demand pipe4.collectCosts.Q_revenue = $START.pipe4.collectCosts.Q_revenue pipe4.collectCosts.W_el_demand = $START.pipe4.collectCosts.W_el_demand pipe4.collectCosts.W_el_revenue = $START.pipe4.collectCosts.W_el_revenue pipe2.collectCosts.other_demand = $START.pipe2.collectCosts.other_demand pipe2.collectCosts.other_revenue = $START.pipe2.collectCosts.other_revenue pipe2.collectCosts.H_demand = $START.pipe2.collectCosts.H_demand pipe2.collectCosts.H_revenue = $START.pipe2.collectCosts.H_revenue pipe2.collectCosts.Q_demand = $START.pipe2.collectCosts.Q_demand pipe2.collectCosts.Q_revenue = $START.pipe2.collectCosts.Q_revenue pipe2.collectCosts.W_el_demand = $START.pipe2.collectCosts.W_el_demand pipe2.collectCosts.W_el_revenue = $START.pipe2.collectCosts.W_el_revenue pipe1.collectCosts.other_demand = $START.pipe1.collectCosts.other_demand pipe1.collectCosts.other_revenue = $START.pipe1.collectCosts.other_revenue pipe1.collectCosts.H_demand = $START.pipe1.collectCosts.H_demand pipe1.collectCosts.H_revenue = $START.pipe1.collectCosts.H_revenue pipe1.collectCosts.Q_demand = $START.pipe1.collectCosts.Q_demand pipe1.collectCosts.Q_revenue = $START.pipe1.collectCosts.Q_revenue pipe1.collectCosts.W_el_demand = $START.pipe1.collectCosts.W_el_demand pipe1.collectCosts.W_el_revenue = $START.pipe1.collectCosts.W_el_revenue modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg pipe3.collectCosts.m_CDE_consumed = $START.pipe3.collectCosts.m_CDE_consumed pipe3.collectCosts.m_CDE_produced = $START.pipe3.collectCosts.m_CDE_produced pipe4.collectCosts.m_CDE_consumed = $START.pipe4.collectCosts.m_CDE_consumed pipe4.collectCosts.m_CDE_produced = $START.pipe4.collectCosts.m_CDE_produced pipe2.collectCosts.m_CDE_consumed = $START.pipe2.collectCosts.m_CDE_consumed pipe2.collectCosts.m_CDE_produced = $START.pipe2.collectCosts.m_CDE_produced pipe1.collectCosts.m_CDE_consumed = $START.pipe1.collectCosts.m_CDE_consumed pipe1.collectCosts.m_CDE_produced = $START.pipe1.collectCosts.m_CDE_produced sink1.m = $START.sink1.m sink2.m = $START.sink2.m source1.m = $START.source1.m source2.m = $START.source2.m. Notification: Performance of preBalanceInitialSystem (initialization_lambda0): time 0.1117/18.91, allocations: 53.21 MB / 6.998 GB, free: 0.6101 GB / 2.405 GB Notification: Performance of partitionIndependentBlocks (initialization_lambda0): time 0.08121/19, allocations: 47.35 MB / 7.044 GB, free: 0.5603 GB / 2.405 GB Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] (0.0 = $START.modelStatistics.heatingPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] (0.0 = $START.modelStatistics.heatingPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] (0.0 = $START.modelStatistics.heatingPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] (0.0 = $START.modelStatistics.heatingPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] (0.0 = $START.modelStatistics.heatingPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] (0.0 = $START.modelStatistics.heatingPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] (0.0 = $START.modelStatistics.electricPower.negPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] (0.0 = $START.modelStatistics.electricPower.negPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] (0.0 = $START.modelStatistics.electricPower.negPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] (0.0 = $START.modelStatistics.electricPower.negPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] (0.0 = $START.modelStatistics.electricPower.negPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] (0.0 = $START.modelStatistics.electricPower.negPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] (0.0 = $START.modelStatistics.electricPower.posPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] (0.0 = $START.modelStatistics.electricPower.posPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] (0.0 = $START.modelStatistics.electricPower.posPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] (0.0 = $START.modelStatistics.electricPower.posPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] (0.0 = $START.modelStatistics.electricPower.posPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] (0.0 = $START.modelStatistics.electricPower.posPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] (0.0 = $START.modelStatistics.electricPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] (0.0 = $START.modelStatistics.electricPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] (0.0 = $START.modelStatistics.electricPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] (0.0 = $START.modelStatistics.electricPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] (0.0 = $START.modelStatistics.electricPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] (0.0 = $START.modelStatistics.electricPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[14]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[13]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[12]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[11]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.other_demand = $START.pipe3.collectCosts.other_demand (0.0 = $START.pipe3.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.other_revenue = $START.pipe3.collectCosts.other_revenue (0.0 = $START.pipe3.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.H_demand = $START.pipe3.collectCosts.H_demand (0.0 = $START.pipe3.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.H_revenue = $START.pipe3.collectCosts.H_revenue (0.0 = $START.pipe3.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.Q_demand = $START.pipe3.collectCosts.Q_demand (0.0 = $START.pipe3.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.Q_revenue = $START.pipe3.collectCosts.Q_revenue (0.0 = $START.pipe3.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.W_el_demand = $START.pipe3.collectCosts.W_el_demand (0.0 = $START.pipe3.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.W_el_revenue = $START.pipe3.collectCosts.W_el_revenue (0.0 = $START.pipe3.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.other_demand = $START.pipe4.collectCosts.other_demand (0.0 = $START.pipe4.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.other_revenue = $START.pipe4.collectCosts.other_revenue (0.0 = $START.pipe4.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.H_demand = $START.pipe4.collectCosts.H_demand (0.0 = $START.pipe4.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.H_revenue = $START.pipe4.collectCosts.H_revenue (0.0 = $START.pipe4.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.Q_demand = $START.pipe4.collectCosts.Q_demand (0.0 = $START.pipe4.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.Q_revenue = $START.pipe4.collectCosts.Q_revenue (0.0 = $START.pipe4.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.W_el_demand = $START.pipe4.collectCosts.W_el_demand (0.0 = $START.pipe4.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.W_el_revenue = $START.pipe4.collectCosts.W_el_revenue (0.0 = $START.pipe4.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.other_demand = $START.pipe2.collectCosts.other_demand (0.0 = $START.pipe2.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.other_revenue = $START.pipe2.collectCosts.other_revenue (0.0 = $START.pipe2.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.H_demand = $START.pipe2.collectCosts.H_demand (0.0 = $START.pipe2.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.H_revenue = $START.pipe2.collectCosts.H_revenue (0.0 = $START.pipe2.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.Q_demand = $START.pipe2.collectCosts.Q_demand (0.0 = $START.pipe2.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.Q_revenue = $START.pipe2.collectCosts.Q_revenue (0.0 = $START.pipe2.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.W_el_demand = $START.pipe2.collectCosts.W_el_demand (0.0 = $START.pipe2.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.W_el_revenue = $START.pipe2.collectCosts.W_el_revenue (0.0 = $START.pipe2.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.other_demand = $START.pipe1.collectCosts.other_demand (0.0 = $START.pipe1.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.other_revenue = $START.pipe1.collectCosts.other_revenue (0.0 = $START.pipe1.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.H_demand = $START.pipe1.collectCosts.H_demand (0.0 = $START.pipe1.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.H_revenue = $START.pipe1.collectCosts.H_revenue (0.0 = $START.pipe1.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.Q_demand = $START.pipe1.collectCosts.Q_demand (0.0 = $START.pipe1.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.Q_revenue = $START.pipe1.collectCosts.Q_revenue (0.0 = $START.pipe1.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.W_el_demand = $START.pipe1.collectCosts.W_el_demand (0.0 = $START.pipe1.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.W_el_revenue = $START.pipe1.collectCosts.W_el_revenue (0.0 = $START.pipe1.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] (0.0 = $START.modelStatistics.electricPower.negSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] (0.0 = $START.modelStatistics.electricPower.negSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] (0.0 = $START.modelStatistics.electricPower.negSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] (0.0 = $START.modelStatistics.electricPower.negSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] (0.0 = $START.modelStatistics.electricPower.negSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] (0.0 = $START.modelStatistics.electricPower.negSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] (0.0 = $START.modelStatistics.electricPower.posSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] (0.0 = $START.modelStatistics.electricPower.posSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] (0.0 = $START.modelStatistics.electricPower.posSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] (0.0 = $START.modelStatistics.electricPower.posSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] (0.0 = $START.modelStatistics.electricPower.posSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] (0.0 = $START.modelStatistics.electricPower.posSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos (0.0 = $START.modelStatistics.electricPower.E_residual_pos) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg (0.0 = $START.modelStatistics.electricPower.E_residual_neg) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.m_CDE_consumed = $START.pipe3.collectCosts.m_CDE_consumed (0.0 = $START.pipe3.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.collectCosts.m_CDE_produced = $START.pipe3.collectCosts.m_CDE_produced (0.0 = $START.pipe3.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.m_CDE_consumed = $START.pipe4.collectCosts.m_CDE_consumed (0.0 = $START.pipe4.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.collectCosts.m_CDE_produced = $START.pipe4.collectCosts.m_CDE_produced (0.0 = $START.pipe4.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.m_CDE_consumed = $START.pipe2.collectCosts.m_CDE_consumed (0.0 = $START.pipe2.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.m_CDE_produced = $START.pipe2.collectCosts.m_CDE_produced (0.0 = $START.pipe2.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.m_CDE_consumed = $START.pipe1.collectCosts.m_CDE_consumed (0.0 = $START.pipe1.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.m_CDE_produced = $START.pipe1.collectCosts.m_CDE_produced (0.0 = $START.pipe1.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: sink1.m = $START.sink1.m (0.0 = $START.sink1.m) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: sink2.m = $START.sink2.m (0.0 = $START.sink2.m) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: source1.m = $START.source1.m (0.0 = $START.source1.m) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: source2.m = $START.source2.m (0.0 = $START.source2.m) Notification: Performance of analyzeInitialSystem (initialization_lambda0): time 0.9093/19.9, allocations: 361.8 MB / 7.397 GB, free: 206.7 MB / 2.405 GB Notification: Performance of solveInitialSystemEqSystem (initialization_lambda0): time 0.000562/19.91, allocations: 75.94 kB / 7.397 GB, free: 206.6 MB / 2.405 GB Notification: Performance of matching and sorting (n=6843) (initialization_lambda0): time 0.2196/20.12, allocations: 96 MB / 7.491 GB, free: 113.2 MB / 2.405 GB Notification: Performance of prepare postOptimizeDAE: time 0.0007104/20.13, allocations: 121.4 kB / 7.491 GB, free: 113 MB / 2.405 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.00383/20.13, allocations: 1.003 MB / 7.492 GB, free: 112 MB / 2.405 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.01116/20.14, allocations: 4.263 MB / 7.496 GB, free: 107.7 MB / 2.405 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.06973/20.21, allocations: 10.12 MB / 7.506 GB, free: 97.54 MB / 2.405 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.0609/20.27, allocations: 84.94 MB / 7.589 GB, free: 7.672 MB / 2.405 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.05936/20.33, allocations: 1.761 MB / 7.591 GB, free: 5.988 MB / 2.405 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.01564/20.35, allocations: 1.941 MB / 7.593 GB, free: 4.047 MB / 2.405 GB Warning: Assuming fixed start value for the following 69 variables: realGasCompositionByWtFractions_stepVariationXi_1_1.t_lastchange:VARIABLE(start = 0.0 unit = "s" fixed = true ) type: Real pipe1.h[1]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[1] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[2]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[2] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[3]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[3] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[4]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[4] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[5]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[5] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[6]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[6] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[7]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[7] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[8]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[8] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[9]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[9] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.h[10]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[10] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe1.p[1]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[1] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[2]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[2] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[3]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[3] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[4]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[4] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[5]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[5] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[6]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[6] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[7]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[7] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[8]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[8] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[9]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[9] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe1.p[10]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[10] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe2.h[1]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[1] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe2.h[2]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[2] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe2.h[3]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[3] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe2.h[4]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[4] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe2.p[1]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[1] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] pipe2.p[2]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[2] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] pipe2.p[3]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[3] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] pipe2.p[4]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[4] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] pipe4.h[1]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[1] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[2]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[2] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[3]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[3] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[4]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[4] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[5]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[5] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[6]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[6] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[7]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[7] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[8]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[8] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[9]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[9] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.h[10]:VARIABLE(start = pipe4.mechanicalEquilibrium.h_start[10] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [10] pipe4.p[1]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[1] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[2]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[2] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[3]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[3] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[4]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[4] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[5]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[5] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[6]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[6] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[7]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[7] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[8]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[8] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[9]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[9] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe4.p[10]:VARIABLE(min = 0.0 start = pipe4.p_start_internal[10] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [10] pipe3.h[1]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[1] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe3.h[2]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[2] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe3.h[3]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[3] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe3.h[4]:VARIABLE(start = pipe3.mechanicalEquilibrium.h_start[4] unit = "J/kg" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) "Cell enthalpy" type: Real [4] pipe3.p[1]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[1] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] pipe3.p[2]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[2] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] pipe3.p[3]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[3] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] pipe3.p[4]:VARIABLE(min = 0.0 start = pipe3.p_start_internal[4] unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) "Cell pressure" type: Real [4] split1.h:VARIABLE(start = Init.split1.h_in unit = "J/kg" fixed = true nominal = 1000.0 ) "Specific enthalpy" type: Real mix2.h:VARIABLE(start = Init.mix2.h_out unit = "J/kg" fixed = true nominal = 1000.0 ) "Specific enthalpy" type: Real mix2.p:VARIABLE(min = 0.0 start = Init.mix2.p unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real split2.h:VARIABLE(start = Init.split2.h_in unit = "J/kg" fixed = true nominal = 1000.0 ) "Specific enthalpy" type: Real mix1.h:VARIABLE(start = Init.mix1.h_out unit = "J/kg" fixed = true nominal = 1000.0 ) "Specific enthalpy" type: Real mix1.p:VARIABLE(min = 0.0 start = Init.mix1.p unit = "Pa" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer ) type: Real realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[1]:VARIABLE(min = 0.0 max = 1.0 start = 0.722090178 unit = "1" fixed = true ) type: Real [6] realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[2]:VARIABLE(min = 0.0 max = 1.0 start = 0.139591715 unit = "1" fixed = true ) type: Real [6] realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[3]:VARIABLE(min = 0.0 max = 1.0 start = 0.069014479 unit = "1" fixed = true ) type: Real [6] realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[4]:VARIABLE(min = 0.0 max = 1.0 start = 0.019245659 unit = "1" fixed = true ) type: Real [6] realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[5]:VARIABLE(min = 0.0 max = 1.0 start = 0.026650142 unit = "1" fixed = true ) type: Real [6] realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[6]:VARIABLE(min = 0.0 max = 1.0 start = 0.023407827 unit = "1" fixed = true ) type: Real [6] Warning: The initial conditions are over specified. The following 106 initial equations are redundant, so they are removed from the initialization_lambda0 system: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] pipe3.collectCosts.other_demand = $START.pipe3.collectCosts.other_demand pipe3.collectCosts.other_revenue = $START.pipe3.collectCosts.other_revenue pipe3.collectCosts.H_demand = $START.pipe3.collectCosts.H_demand pipe3.collectCosts.H_revenue = $START.pipe3.collectCosts.H_revenue pipe3.collectCosts.Q_demand = $START.pipe3.collectCosts.Q_demand pipe3.collectCosts.Q_revenue = $START.pipe3.collectCosts.Q_revenue pipe3.collectCosts.W_el_demand = $START.pipe3.collectCosts.W_el_demand pipe3.collectCosts.W_el_revenue = $START.pipe3.collectCosts.W_el_revenue pipe4.collectCosts.other_demand = $START.pipe4.collectCosts.other_demand pipe4.collectCosts.other_revenue = $START.pipe4.collectCosts.other_revenue pipe4.collectCosts.H_demand = $START.pipe4.collectCosts.H_demand pipe4.collectCosts.H_revenue = $START.pipe4.collectCosts.H_revenue pipe4.collectCosts.Q_demand = $START.pipe4.collectCosts.Q_demand pipe4.collectCosts.Q_revenue = $START.pipe4.collectCosts.Q_revenue pipe4.collectCosts.W_el_demand = $START.pipe4.collectCosts.W_el_demand pipe4.collectCosts.W_el_revenue = $START.pipe4.collectCosts.W_el_revenue pipe2.collectCosts.other_demand = $START.pipe2.collectCosts.other_demand pipe2.collectCosts.other_revenue = $START.pipe2.collectCosts.other_revenue pipe2.collectCosts.H_demand = $START.pipe2.collectCosts.H_demand pipe2.collectCosts.H_revenue = $START.pipe2.collectCosts.H_revenue pipe2.collectCosts.Q_demand = $START.pipe2.collectCosts.Q_demand pipe2.collectCosts.Q_revenue = $START.pipe2.collectCosts.Q_revenue pipe2.collectCosts.W_el_demand = $START.pipe2.collectCosts.W_el_demand pipe2.collectCosts.W_el_revenue = $START.pipe2.collectCosts.W_el_revenue pipe1.collectCosts.other_demand = $START.pipe1.collectCosts.other_demand pipe1.collectCosts.other_revenue = $START.pipe1.collectCosts.other_revenue pipe1.collectCosts.H_demand = $START.pipe1.collectCosts.H_demand pipe1.collectCosts.H_revenue = $START.pipe1.collectCosts.H_revenue pipe1.collectCosts.Q_demand = $START.pipe1.collectCosts.Q_demand pipe1.collectCosts.Q_revenue = $START.pipe1.collectCosts.Q_revenue pipe1.collectCosts.W_el_demand = $START.pipe1.collectCosts.W_el_demand pipe1.collectCosts.W_el_revenue = $START.pipe1.collectCosts.W_el_revenue modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg pipe3.collectCosts.m_CDE_consumed = $START.pipe3.collectCosts.m_CDE_consumed pipe3.collectCosts.m_CDE_produced = $START.pipe3.collectCosts.m_CDE_produced pipe4.collectCosts.m_CDE_consumed = $START.pipe4.collectCosts.m_CDE_consumed pipe4.collectCosts.m_CDE_produced = $START.pipe4.collectCosts.m_CDE_produced pipe2.collectCosts.m_CDE_consumed = $START.pipe2.collectCosts.m_CDE_consumed pipe2.collectCosts.m_CDE_produced = $START.pipe2.collectCosts.m_CDE_produced pipe1.collectCosts.m_CDE_consumed = $START.pipe1.collectCosts.m_CDE_consumed pipe1.collectCosts.m_CDE_produced = $START.pipe1.collectCosts.m_CDE_produced sink1.m = $START.sink1.m sink2.m = $START.sink2.m source1.m = $START.source1.m source2.m = $START.source2.m. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 1176 * Number of states: 0 () * Number of discrete variables: 15 ($PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$whenCondition3,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$whenCondition2,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$whenCondition1,pipe3.heatTransfer.table_block.tableID,pipe4.heatTransfer.table_block.tableID,pipe2.heatTransfer.table_block.tableID,pipe1.heatTransfer.table_block.tableID) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (4603): * Single equations (assignments): 4343 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 192 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 32 * Torn equation systems: 36 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 32 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 30 systems {(1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 6 systems {(1,21), (1,8), (1,8), (1,21), (1,8), (1,8)} Notification: Performance of prepare postOptimizeDAE: time 0.03456/20.38, allocations: 3.597 MB / 7.596 GB, free: 0.5469 MB / 2.405 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.0256/20.41, allocations: 4.79 MB / 7.601 GB, free: 13.41 MB / 2.42 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 1.893/22.3, allocations: 85.1 MB / 7.684 GB, free: 0.7829 GB / 2.436 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.001015/22.3, allocations: 326.5 kB / 7.684 GB, free: 0.7829 GB / 2.436 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.000508/22.3, allocations: 74.72 kB / 7.685 GB, free: 0.7829 GB / 2.436 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.1579/22.46, allocations: 74.84 MB / 7.758 GB, free: 0.7562 GB / 2.436 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.3548/22.81, allocations: 188.7 MB / 7.942 GB, free: 0.5962 GB / 2.436 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.00347/22.82, allocations: 0.8041 MB / 7.943 GB, free: 0.5954 GB / 2.436 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.05821/22.88, allocations: 6.143 MB / 7.949 GB, free: 0.5894 GB / 2.436 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.01663/22.89, allocations: 6.325 MB / 7.955 GB, free: 0.5834 GB / 2.436 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.01164/22.9, allocations: 1.123 MB / 7.956 GB, free: 0.5823 GB / 2.436 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.05577/22.96, allocations: 87.95 MB / 8.042 GB, free: 0.4919 GB / 2.436 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 4.268e-05/22.96, allocations: 95.56 kB / 8.042 GB, free: 0.4918 GB / 2.436 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.2494/23.21, allocations: 131.3 MB / 8.17 GB, free: 373.6 MB / 2.436 GB Notification: Performance of postOpt removeConstants (simulation): time 0.04196/23.25, allocations: 13.03 MB / 8.183 GB, free: 363.3 MB / 2.436 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.02343/23.27, allocations: 0.8005 MB / 8.184 GB, free: 362.5 MB / 2.436 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.04216/23.32, allocations: 1.121 MB / 8.185 GB, free: 361.4 MB / 2.436 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.01324/23.33, allocations: 1.737 MB / 8.187 GB, free: 359.7 MB / 2.436 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.01091/23.34, allocations: 1.237 MB / 8.188 GB, free: 358.4 MB / 2.436 GB Notification: Performance of sorting global known variables: time 0.07488/23.42, allocations: 31.03 MB / 8.218 GB, free: 327.7 MB / 2.436 GB Notification: Performance of sort global known variables: time 4.21e-07/23.42, allocations: 0 / 8.218 GB, free: 327.7 MB / 2.436 GB Notification: Performance of remove unused functions: time 0.1263/23.54, allocations: 20.44 MB / 8.238 GB, free: 307.3 MB / 2.436 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 264 * Number of states: 261 (pipe1.h[1],pipe1.h[2],pipe1.h[3],pipe1.h[4],pipe1.h[5],pipe1.h[6],pipe1.h[7],pipe1.h[8],pipe1.h[9],pipe1.h[10],pipe1.p[1],pipe1.p[2],pipe1.p[3],pipe1.p[4],pipe1.p[5],pipe1.p[6],pipe1.p[7],pipe1.p[8],pipe1.p[9],pipe1.p[10],pipe1.xi[1,1],pipe1.xi[1,2],pipe1.xi[1,3],pipe1.xi[1,4],pipe1.xi[1,5],pipe1.xi[1,6],pipe1.xi[2,1],pipe1.xi[2,2],pipe1.xi[2,3],pipe1.xi[2,4],pipe1.xi[2,5],pipe1.xi[2,6],pipe1.xi[3,1],pipe1.xi[3,2],pipe1.xi[3,3],pipe1.xi[3,4],pipe1.xi[3,5],pipe1.xi[3,6],pipe1.xi[4,1],pipe1.xi[4,2],pipe1.xi[4,3],pipe1.xi[4,4],pipe1.xi[4,5],pipe1.xi[4,6],pipe1.xi[5,1],pipe1.xi[5,2],pipe1.xi[5,3],pipe1.xi[5,4],pipe1.xi[5,5],pipe1.xi[5,6],pipe1.xi[6,1],pipe1.xi[6,2],pipe1.xi[6,3],pipe1.xi[6,4],pipe1.xi[6,5],pipe1.xi[6,6],pipe1.xi[7,1],pipe1.xi[7,2],pipe1.xi[7,3],pipe1.xi[7,4],pipe1.xi[7,5],pipe1.xi[7,6],pipe1.xi[8,1],pipe1.xi[8,2],pipe1.xi[8,3],pipe1.xi[8,4],pipe1.xi[8,5],pipe1.xi[8,6],pipe1.xi[9,1],pipe1.xi[9,2],pipe1.xi[9,3],pipe1.xi[9,4],pipe1.xi[9,5],pipe1.xi[9,6],pipe1.xi[10,1],pipe1.xi[10,2],pipe1.xi[10,3],pipe1.xi[10,4],pipe1.xi[10,5],pipe1.xi[10,6],pipe2.h[1],pipe2.h[2],pipe2.h[3],pipe2.h[4],pipe2.p[1],pipe2.p[2],pipe2.p[3],pipe2.p[4],pipe2.xi[1,1],pipe2.xi[1,2],pipe2.xi[1,3],pipe2.xi[1,4],pipe2.xi[1,5],pipe2.xi[1,6],pipe2.xi[2,1],pipe2.xi[2,2],pipe2.xi[2,3],pipe2.xi[2,4],pipe2.xi[2,5],pipe2.xi[2,6],pipe2.xi[3,1],pipe2.xi[3,2],pipe2.xi[3,3],pipe2.xi[3,4],pipe2.xi[3,5],pipe2.xi[3,6],pipe2.xi[4,1],pipe2.xi[4,2],pipe2.xi[4,3],pipe2.xi[4,4],pipe2.xi[4,5],pipe2.xi[4,6],pipe4.h[1],pipe4.h[2],pipe4.h[3],pipe4.h[4],pipe4.h[5],pipe4.h[6],pipe4.h[7],pipe4.h[8],pipe4.h[9],pipe4.h[10],pipe4.p[1],pipe4.p[2],pipe4.p[3],pipe4.p[4],pipe4.p[5],pipe4.p[6],pipe4.p[7],pipe4.p[8],pipe4.p[9],pipe4.p[10],pipe4.xi[1,1],pipe4.xi[1,2],pipe4.xi[1,3],pipe4.xi[1,4],pipe4.xi[1,5],pipe4.xi[1,6],pipe4.xi[2,1],pipe4.xi[2,2],pipe4.xi[2,3],pipe4.xi[2,4],pipe4.xi[2,5],pipe4.xi[2,6],pipe4.xi[3,1],pipe4.xi[3,2],pipe4.xi[3,3],pipe4.xi[3,4],pipe4.xi[3,5],pipe4.xi[3,6],pipe4.xi[4,1],pipe4.xi[4,2],pipe4.xi[4,3],pipe4.xi[4,4],pipe4.xi[4,5],pipe4.xi[4,6],pipe4.xi[5,1],pipe4.xi[5,2],pipe4.xi[5,3],pipe4.xi[5,4],pipe4.xi[5,5],pipe4.xi[5,6],pipe4.xi[6,1],pipe4.xi[6,2],pipe4.xi[6,3],pipe4.xi[6,4],pipe4.xi[6,5],pipe4.xi[6,6],pipe4.xi[7,1],pipe4.xi[7,2],pipe4.xi[7,3],pipe4.xi[7,4],pipe4.xi[7,5],pipe4.xi[7,6],pipe4.xi[8,1],pipe4.xi[8,2],pipe4.xi[8,3],pipe4.xi[8,4],pipe4.xi[8,5],pipe4.xi[8,6],pipe4.xi[9,1],pipe4.xi[9,2],pipe4.xi[9,3],pipe4.xi[9,4],pipe4.xi[9,5],pipe4.xi[9,6],pipe4.xi[10,1],pipe4.xi[10,2],pipe4.xi[10,3],pipe4.xi[10,4],pipe4.xi[10,5],pipe4.xi[10,6],pipe3.h[1],pipe3.h[2],pipe3.h[3],pipe3.h[4],pipe3.p[1],pipe3.p[2],pipe3.p[3],pipe3.p[4],pipe3.xi[1,1],pipe3.xi[1,2],pipe3.xi[1,3],pipe3.xi[1,4],pipe3.xi[1,5],pipe3.xi[1,6],pipe3.xi[2,1],pipe3.xi[2,2],pipe3.xi[2,3],pipe3.xi[2,4],pipe3.xi[2,5],pipe3.xi[2,6],pipe3.xi[3,1],pipe3.xi[3,2],pipe3.xi[3,3],pipe3.xi[3,4],pipe3.xi[3,5],pipe3.xi[3,6],pipe3.xi[4,1],pipe3.xi[4,2],pipe3.xi[4,3],pipe3.xi[4,4],pipe3.xi[4,5],pipe3.xi[4,6],split1.gasBulk.xi[1],split1.gasBulk.xi[2],split1.gasBulk.xi[3],split1.gasBulk.xi[4],split1.gasBulk.xi[5],split1.gasBulk.xi[6],split1.h,mix2.gasBulk.xi[1],mix2.gasBulk.xi[2],mix2.gasBulk.xi[3],mix2.gasBulk.xi[4],mix2.gasBulk.xi[5],mix2.gasBulk.xi[6],mix2.h,mix2.p,split2.gasBulk.xi[1],split2.gasBulk.xi[2],split2.gasBulk.xi[3],split2.gasBulk.xi[4],split2.gasBulk.xi[5],split2.gasBulk.xi[6],split2.h,mix1.gasBulk.xi[1],mix1.gasBulk.xi[2],mix1.gasBulk.xi[3],mix1.gasBulk.xi[4],mix1.gasBulk.xi[5],mix1.gasBulk.xi[6],mix1.h,mix1.p,realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[1],realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[2],realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[3],realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[4],realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[5],realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[6],realGasCompositionByWtFractions_stepVariationXi_1_1.t_lastchange) * Number of discrete variables: 11 ($whenCondition1,pipe1.heatTransfer.table_block.tableID,pipe2.heatTransfer.table_block.tableID,pipe4.heatTransfer.table_block.tableID,pipe3.heatTransfer.table_block.tableID,$whenCondition2,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,$whenCondition3,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled) * Number of discrete states: 10 (simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[1],realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[2],realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[3],realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[4],realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[5],realGasCompositionByWtFractions_stepVariationXi_1_1.xi_in[6]) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (2185): * Single equations (assignments): 1917 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 192 * When equations: 8 * If-equations: 0 * Equation systems (not torn): 32 * Torn equation systems: 36 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 32 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 30 systems {(1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 6 systems {(1,21), (1,21), (1,8), (1,8), (1,8), (1,8)} [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so Notification: Performance of Backend phase and start with SimCode phase: time 0.01776/23.56, allocations: 2.476 MB / 8.24 GB, free: 305.7 MB / 2.436 GB Notification: Performance of simCode: created initialization part: time 0.272/23.83, allocations: 161.1 MB / 8.398 GB, free: 141.9 MB / 2.436 GB Notification: Performance of simCode: created event and clocks part: time 7.826e-05/23.83, allocations: 12.56 kB / 8.398 GB, free: 141.9 MB / 2.436 GB Notification: Performance of simCode: created simulation system equations: time 0.08774/23.92, allocations: 53.16 MB / 8.45 GB, free: 87.29 MB / 2.436 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.1182/24.04, allocations: 12.2 MB / 8.462 GB, free: 75.24 MB / 2.436 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[4,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[4,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[4,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[4,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[4,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[4,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[3,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[3,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[3,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[3,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[3,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[3,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[2,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[2,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[2,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[2,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[2,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[2,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[1,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[1,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[1,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[1,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[1,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.xi[1,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[10,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[10,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[10,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[10,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[10,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[10,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[9,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[9,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[9,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[9,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[9,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[9,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[8,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[8,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[8,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[8,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[8,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[8,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[7,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[7,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[7,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[7,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[7,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[7,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[6,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[6,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[6,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[6,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[6,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[6,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[5,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[5,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[5,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[5,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[5,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[5,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[4,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[4,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[4,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[4,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[4,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[4,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[3,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[3,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[3,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[3,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[3,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[3,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[2,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[2,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[2,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[2,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[2,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[2,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[1,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[1,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[1,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[1,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[1,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe4.xi[1,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[4,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[4,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[4,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[4,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[4,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[4,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[3,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[3,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[3,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[3,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[3,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[3,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[2,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[2,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[2,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[2,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[2,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[2,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[1,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[1,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[1,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[1,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[1,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe2.xi[1,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[10,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[10,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[10,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[10,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[10,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[10,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[9,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[9,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[9,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[9,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[9,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[9,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[8,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[8,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[8,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[8,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[8,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[8,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[7,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[7,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[7,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[7,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[7,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[7,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[6,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[6,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[6,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[6,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[6,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[6,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[5,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[5,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[5,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[5,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[5,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[5,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[4,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[4,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[4,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[4,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[4,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[4,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[3,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[3,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[3,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[3,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[3,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[3,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[2,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[2,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[2,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[2,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[2,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[2,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[1,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[1,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[1,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[1,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[1,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[1,1] has attribute stateSelect=StateSelect.never, but was selected as a state Warning: The hideResult annotation could not be evaluated, probably due to missing annotation(Evaluate=true). It is removed. Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 1.544/25.58, allocations: 143.9 MB / 8.602 GB, free: 0.7209 GB / 2.436 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.06632/25.65, allocations: 26.13 MB / 8.628 GB, free: 0.7189 GB / 2.436 GB Notification: Performance of simCode: alias equations: time 0.0882/25.74, allocations: 23.07 MB / 8.65 GB, free: 0.7185 GB / 2.436 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.03072/25.77, allocations: 3.199 MB / 8.653 GB, free: 0.7185 GB / 2.436 GB Notification: Performance of SimCode: time 1.863e-06/25.77, allocations: 0 / 8.653 GB, free: 0.7185 GB / 2.436 GB Notification: Performance of Templates: time 2.556/28.32, allocations: 0.8233 GB / 9.477 GB, free: 0.7519 GB / 2.452 GB make -j1 -f TransiEnt_TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCyc2Source4Pipes2Sinks.makefile (rm -f TransiEnt_TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCyc2Source4Pipes2Sinks.pipe ; mkfifo TransiEnt_TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCyc2Source4Pipes2Sinks.pipe ; head -c 1048576 < TransiEnt_TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCyc2Source4Pipes2Sinks.pipe >> ../files/TransiEnt_TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCyc2Source4Pipes2Sinks.sim & ./TransiEnt_TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCyc2Source4Pipes2Sinks -abortSlowSimulation -alarm=480 -lv LOG_STATS > TransiEnt_TransiEnt.Grid.Gas.StaticCycles.Check.TestStatCyc2Source4Pipes2Sinks.pipe 2>&1)