Environment - simulationEnvironment: startTime=0 stopTime=100 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.1 Regular simulation: ./ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.CounterFlowNTU_serial -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00703967s reading init.xml | | | | | | 0.000767249s reading info.xml | | | | | | 0.000365646s [ 1.9%] pre-initialization | | | | | | 0.000292759s [ 1.5%] initialization | | | | | | 7.985e-06s [ 0.0%] steps | | | | | | 0.000330633s [ 1.7%] solver (excl. callbacks) | | | | | | 0.000517952s [ 2.7%] creating output-file | | | | | | 7.392e-06s [ 0.0%] event-handling | | | | | | 0.00255528s [ 13.4%] overhead | | | | | | 0.0150502s [ 78.7%] simulation | | | | | | 0.0191278s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 234 steps taken | | | | | | 294 calls of functionODE | | | | | | 68 evaluations of jacobian | | | | | | 9 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00231977s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.