Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_4 -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/CentrifugalPump.mo:95:3-95:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((centrifugalPump.hn >= 0.0)) --> "Variable violating min constraint: 0.0 <= centrifugalPump.hn, has value: -0.00993504" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00599686s reading init.xml | | | | | | 0.00050636s reading info.xml | | | | | | 0.000139873s [ 0.0%] pre-initialization | | | | | | 0.0167386s [ 2.7%] initialization | | | | | | 0.000247444s [ 0.0%] steps | | | | | | 0.00137467s [ 0.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000276203s [ 0.0%] event-handling | | | | | | 0.0123824s [ 2.0%] overhead | | | | | | 0.595591s [ 95.0%] simulation | | | | | | 0.62675s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 171 steps taken | | | | | | 273 calls of functionODE | | | | | | 59 evaluations of jacobian | | | | | | 15 error test failures | | | | | | 6 convergence test failures | | | | | | 0.00928035s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.