Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=500 stepSize=0.002 Regular simulation: ./TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.FluidDynamics.Components.Machines.test_PrescribedPump -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00339599s reading init.xml | | | | | | 0.00022941s reading info.xml | | | | | | 6.0774e-05s [ 0.0%] pre-initialization | | | | | | 0.00534675s [ 2.6%] initialization | | | | | | 0.000176371s [ 0.1%] steps | | | | | | 1.5299e-05s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 4.242e-06s [ 0.0%] event-handling | | | | | | 0.00317221s [ 1.6%] overhead | | | | | | 0.195135s [ 95.7%] simulation | | | | | | 0.203911s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 1000 steps taken | | | | | | 1000 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.